The Thermo Scientific Tundra Cryo-Transmission Electron Microscope (Cryo-TEM) is a dedicated structure-determination solution designed to bring single particle analysis to every biochemistry laboratory. It is easier to use than typical cryo-TEM instruments, fits into a standard lab space, and matches grant mechanisms and funding opportunities globally. The Tundra Cryo-TEM is a powerful tool that can help answer your most challenging research questions, offering structural determination at biologically relevant resolutions.

Key Features

Quickly optimize your sample

Quickly optimize your sample and have confidence in your data collection, whether you’re performing your analysis on site or at an external facility (i.e. national or core imaging lab).

Reduce wasted time

Eliminate the time lost when samples are rejected by external facilities due to sample quality.

Low-cost cryo-EM

Add cryo-EM capacity to your lab at a lower cost, while still collecting impactful data.

Expanded possibilities for biochemical research

Expand the possibilities of your biochemical research without the need for prior microscopy experience.

Easy, iterative sample-viability determination and biochemistry optimization

The Tundra Cryo-TEM can visualize the impact of biochemical adjustments to samples faster than other technologies.

It only takes a few minutes to exchange samples in and out of the microscope, allowing you to optimize your sample conditions quickly. The microscope was designed to allow new users to do this procedure without extensive training.

Structural information at biologically relevant resolution

The optics of the Tundra Cryo-TEM are specifically designed so that you can answer fundamental questions on biology and human disease with data at biologically relevant resolutions. Our first and only microscope operating at 100 kV, the Tundra Cryo-TEM can generate high-contrast biological images down to 3.5 Å at medium throughput with its high-performance, fraction-enabled Thermo Scientific Ceta Camera.

Space efficient and cost effective

The Tundra Cryo-TEM has been purposefully designed with a smaller footprint and an easier access path. In many cases, this allows you to avoid the additional investment and unwanted downtime that comes with modification of your existing laboratory infrastructure (or even the need for a new, purposely built lab) to accommodate the instrument. Floor plan and installation requirements for the Tundra Cryo-TEM can be found in the product datasheet.

Additionally, a wide range of funding and instrumentation grants were considered when designing the Tundra Cryo-TEM so that its price falls within the reach of most instrumentation grants.

Unique AI algorithms

The Tundra Cryo-TEM comes with a complete suite of automation software for efficient optimization of your sample's biochemistry as well as data collection for structural determination. This includes user-friendly single particle analysis (SPA) data acquisition software, Thermo Scientific EPU 2 Software, guided day-to-day operation, a traffic-light UI element that indicates the microscope’s status, and pre-defined templates for typical use cases that allow you to begin collecting high-resolution data with only a few clicks.

Additionally, the Tundra Cryo-TEM is the debut of smart EPU software, an AI-enabled software solution capable of analyzing intermediate results, providing instant feedback, and steering data collection on the fly. Our AI algorithms are based on years of cryo-EM knowledge, replace decisions that experts need to make upfront, and ensure that your instrument is working at optimal conditions, allowing you to focus on the science rather than on fine-tuning the microscope.

3D structures answer your biological questions

One of the primary challenges of investigating dynamic biological processes, and how they fail in disease, is the complexity inherent to biological machinery. Large and/or dynamic protein systems present a unique challenge to traditional methods of scientific inquiry, which study these systems either indirectly or in isolation. Fortunately, cryo-electron microscopy (cryo-EM) single particle analysis (SPA) has emerged as a well-suited approach for the direct determination of native function and dynamics in complex biological systems.

Single particle analysis can validate your biochemistry work by showing the molecular details that underlie the interactions between proteins, small molecules, and post-translational modifications in large and dynamic protein systems at near native conditions. These molecular details confirm the mechanism of action by which complex biological systems (e.g. membrane proteins, protein complexes, and macromolecular machines such as viruses, ribosomes, and proteasomes) contribute to human health and disease.

For example, the human GABAA (gamma-aminobutyric acid type A) receptor is a small membrane protein and ligand-gated chloride-ion channel that mediates inhibitory neurotransmission. GABAA receptors are important therapeutic targets as their various conformations affect a variety of important signaling pathways. Due to GABAA's conformational flexibility, traditional methods have been unable to reveal its molecular mechanism of action. The ability of cryo-EM to image large, biologically complex structures has, meanwhile, allowed researchers to see the molecular details that underpin the allosteric modulation of this important receptor.

With the Tundra Cryo-TEM, more scientists can have access to this type of information for their complex biological systems. Our applications scientists have used the Tundra Cryo-TEM to determine a 3D structure of GABAA to ~4-5 Å resolution. At this resolution, molecular details such as individual alpha helices and beta sheets are clearly visible, molecular structures can be docked, and molecular interactions modeled. Additionally, the Tundra Cryo-TEM was able to achieve 3 Å resolution for the rigid benchmark protein apoferritin. At this resolution, the protein backbone can be traced, and major amino acid side chains are clearly visible, making de novo model building possible. Data at these resolutions helps you understand how proteins function, how to modify genes, and how to design drugs accordingly.


Specifications

Technical highlights of the Tundra Cryo-TEM

  • 3.5 Å apoferritin structure determination in 24-72 hours
  • High-brightness X-FEG (extreme field emission gun)
  • Fixed accelerating voltage of 100 kV
  • Semi-automated sample loading
  • Cryo-preparation station allowing contamination-free sample exchange
  • Sample transfer device for transferring single AutoGrids to the microscope
    • Fixed cryo-box that keeps samples contamination free for up to 72 hours
  • Computerized specimen cryo-stage
  • High-performance Thermo Scientific Ceta Camera with dose fractionation, optimized for low-dose imaging
  • EPU 2 Software for automated single particle analysis screening and data acquisition
  • Smart EPU Software: an AI-enabled software solution that provides feedback into data collection. Includes an open application programming interface

Resources

Learn about the latest biological research conducted using the new Tundra Cryo-TEM, find out how it’s democratizing cryo-electron microscopy, and engage with our experts and guest speakers during the panel discussion.

Get ready for game-changing access to cryo-EM and see how greater structural insights can solve the most difficult protein structures at the heart of our greatest medical challenges. This will, in turn, help us gain insight into diseases that we have only just begun to understand.

The cryo-loading station is an integral part of the Thermo Scientific Tundra Cryo-TEM. Sample biochemistry can be optimized and subsequently, the structure of the optimized samples can be obtained.
In the Tundra Cryo-TEM, microscope parameters are simplified into a single traffic light to inform you of the microscope status and also to guide you in fixing common problems.

Learn about the latest biological research conducted using the new Tundra Cryo-TEM, find out how it’s democratizing cryo-electron microscopy, and engage with our experts and guest speakers during the panel discussion.

Get ready for game-changing access to cryo-EM and see how greater structural insights can solve the most difficult protein structures at the heart of our greatest medical challenges. This will, in turn, help us gain insight into diseases that we have only just begun to understand.

The cryo-loading station is an integral part of the Thermo Scientific Tundra Cryo-TEM. Sample biochemistry can be optimized and subsequently, the structure of the optimized samples can be obtained.
In the Tundra Cryo-TEM, microscope parameters are simplified into a single traffic light to inform you of the microscope status and also to guide you in fixing common problems.

Applications

Infectious_Disease_Research_App_w274x180

传染病研究
 

冷冻电镜技术可在近天然状态下对生物大分子的 3D 结构进行多尺度的观察,有助于提高治疗方法的开发速度和效率。

Life_Sciences_Application_274x180_144DPI

结构生物学研究
 

冷冻电镜可以对具有挑战性的生物靶标(例如大型复合物、柔性物质和膜蛋白)进行结构分析。


Techniques

单颗粒分析

单颗粒分析 (SPA) 是一种冷冻电镜技术,可实现近原子分辨率的结构表征,揭示动态生物学过程以及生物分子复合物/组装体的结构。

了解更多 ›

单颗粒分析

单颗粒分析 (SPA) 是一种冷冻电镜技术,可实现近原子分辨率的结构表征,揭示动态生物学过程以及生物分子复合物/组装体的结构。

了解更多 ›


Contact us

Style Sheet for Komodo Tabs
产品表格规范样式表
Style Sheet for Global Design System
支持和服务页脚样式表
字体样式表
卡片样式表