Acclaim™ Explosives E2 HPLC Columns
Acclaim™ Explosives E2 HPLC Columns
Thermo Scientific™

Acclaim™ Explosives E2 HPLC Columns

Green features
Use for baseline resolution of all 14 explosives listed in EPA Method 531.2.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberLength (Metric)Diameter (Metric)Particle Size
070081250 mm3 mm3 μm
070082150 mm3 mm3 μm
064309250 mm4.6 mm5 μm
06970310 mm4.6 mm5 μm
07198910 mm3 mm5 μm
076226150 mm2.1 mm2.2 μm
Catalog number 070081
Price (CNY)
-
Length (Metric):
250 mm
Diameter (Metric):
3 mm
Particle Size:
3 μm
Achieve baseline resolution of all 14 explosives listed in EPA SW-846 Method 8330 with Thermo Scientific™ Acclaim™ Explosives E2 LC Columns, Nitroaromatics and Nitramines by HPLC. Their unique column chemistries deliver superior resolution with complementary selectivities. Use the E1 column (available separately) as a direct replacement for ODS columns for primary analysis. Then, use the E2 column as either a primary or a confirmatory column. Easily change the separation conditions for the E2 column to accommodate a wider application range, including the analysis of explosives beyond U.S. EPA Method 8330.
Superior Performance for Explosives Analysis
  • Reproducible performance
  • Simple isocratic elution conditions
  • Unique selectivities for separating other nitroaromatic molecules
  • Rugged columns with good lot-to-lot reproducibility
About the Family of Acclaim Specialty HPLC Columns
  • Developed, manufactured and tested to meet the needs of specific applications
  • Columns provide superior resolution with ease of use
  • Use-tested to guarantee consistent separations
  • Ideal selectivity for separating specific target analytes
  • Excellent peak shapes
  • Performance tested to ensure high quality and reliability
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.
Specifications
Column FormatAnalytical Column
Column TypeSpecialty/Application Specific
EndcappedYes
Flow Rate0.4 to 0.6 mL/min
For Use WithLC/MS
Green FeaturesResponsibly packaged
Max. Pressure11600 psi (800 bar)
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Particle ShapeSpherical
Particle Size Distribution<1.3
Pore Volume0.9 to 1 mL/g
QuantityEach
Stationary PhaseProprietary
Surface Area300 m²/g
Temperature50°C
Diameter (Metric)3 mm
Length (Metric)250 mm
Particle Size3 μm
PhaseReversed Phase
Pore Size120 Å
Product LineAcclaim
TypeAnalytical Column
pH2.5 to 7.5
Unit SizeEach