Forma™ Series II Water-Jacketed CO2 Incubator, 184L
Invitrogen17万+抗体限时买二赠一,靶点广,灵活用!
Forma&trade; Series II Water-Jacketed CO<sub>2</sub> Incubator, 184L
Actual product may vary
Forma&trade; Series II Water-Jacketed CO<sub>2</sub> Incubator, 184L
Forma&trade; Series II Water-Jacketed CO<sub>2</sub> Incubator, 184L
Forma&trade; Series II Water-Jacketed CO<sub>2</sub> Incubator, 184L
Thermo Scientific™

Forma™ Series II Water-Jacketed CO2 Incubator, 184L

Precisely control the CO2 and temperature with Thermo Scientific™ Forma™ Series II 3110 Water-Jacketed CO2 Incubators.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberVoltageCO2 Sensor TechnologyOxygen Control
3111230 VTC SensorNone
3131230 VTC Sensor1 to 21%
3120120 VIR SensorNone
3121230 VIR SensorNone
3140120 VIR Sensor1 to 21%
Catalog number 3111
Price (CNY)
-
Voltage:
230 V
CO2 Sensor Technology:
TC Sensor
Oxygen Control:
None

Thermo Scientific™ Forma™ Series II Water-Jacketed CO2 Incubators provide precise CO2 control, unsurpassed temperature stability and superior parameter recovery characteristics, with continuous contamination control technology. They provide an environment for the growth of microbiological samples or mammalian cells for research (FDA Class 1), and IVF and other regulated cell therapy applications (FDA Class 2).

Water Jacketed Chamber
  • The 184L (6.5 cu. ft.) high capacity chamber provides outstanding culturing space
  • Standard right hand door swing, field reversible 
  • Polished stainless steel interior with coved corners is easy-to-clean with removable humidity pan
  • Unique triple wall construction provides outstanding temperature uniformity and stability
  • Exclusive, heated dual pane inner glass door is designed to minimize condensation
  • In-chamber fan gently distributes air throughout the chamber which is designed ensure homogeneous conditions
  • Sturdy stainless steel shelves and supports can be removed without tools for easy cleaning or adjustment

ISO Class 5 HEPA Filtration Airflow System
  • In-chamber HEPA air filtration continuously filters entire chamber volume every 60 seconds
  • Reaches ISO Class 5 (Class 100) cleanroom air quality in only 5 minutes after door opening
  • Continuous protection by minimizing ability for contaminants to settle on interior surfaces

In situ Sensors and Probes Designed for Precise Monitoring
  • Choice of  TC (thermal conductivity) CO2 sensor for long, reliable operation or  IR (infrared) CO2 sensor  for monitoring when humidity and temperature are less predictable
  • Dual temperature probes with over temperature protection
  • Optional rH display for monitoring humidity levels to prevent “dry-outs"
                                                                                                                                      
Enviro-Scan Microprocessor Control
  • Easy- to-use, alphanumeric LED display
  • Flexible, intuitive controls with message center including process and alarm status messages
  • Configurable audible on/off, access code, tracking low and high alarms
Laboratory Use. It is the customer’s responsibility to ensure that the performance of the product is suitable for customers’ specific uses or applications.
Specifications
Capacity (English)6.5 cu. ft.
Certifications/ComplianceUL, cUL, CE
Data OutputsOptional 4-20mA
DescriptionSingle 184L incubator
Dimensions (D x W x H) Interior20 x 21.3 x 26.8 in. (50.8 x 54.1 x 68.1 cm)
Electrical Requirements230 V, 50/60 Hz
Humidity SourceWater Pan
LightingLED
Oxygen ControlNone
TypeCO2 Incubator
Weight (English)365 lb.
CO2 Concentration Range0 to 20%
CO2 Sensor TechnologyTC Sensor
Capacity (Metric)184 L
Chamber MaterialPolished Stainless Steel
MaterialStainless Steel
Relative Humidity<90% at 37°C
Temperature Range (Metric)Ambient +5° to 50°C
Voltage230 V
Unit SizeEach

Frequently asked questions (FAQs)

Do you supply an HPLC chromatogram for Amyloid beta 1-42?

No, we don't provide a chromatogram since our Amyloid beta 1-42 is supplied as a kit component. Note that Zagorski, et al. (1999) points out that Amyloid beta 1-42 elutes from HPLC columns as an extremely broad peak with poor resolution, and impurities which co-elute with the broad Amyloid beta 1-42 band might not be resolved into separate peaks. When Amyloid beta 1-42-containing fractions are collected from the HPLC column and then re-injected, multiple peaks are still observed. Both of these observations, the broad peak and the formation of multiple peaks upon re-injection, are consistent with aggregation of Amyloid beta 1-42 under these HPLC conditions. Another limitation is that Amyloid beta has been observed to adhere irreversibly to a variety of common HPLC columns. At this time, HPLC analysis is not applicable for assessing Amyloid beta 1-42 purity.

Reference:
Zagorski, M.G., J. Yang, H. Shao, K. Ma, H. Zeng, and A. Hong (1999) Methodological and chemical factors affecting amyloid? peptide amyloidogenicity. Meth. Enzymol. 309:189-204.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.