Search Thermo Fisher Scientific
- Contact Us
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
Detectable Analytes | Sulfur Dioxide |
Flow Rate | 0.5 L/min. (standard), 1 L/min. (optional) |
Inputs | 16 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional) |
Linearity | ±1% full scale |
Response Time | <20 sec. (lag time) (60 sec. or less average time), <100 sec. (rise time), <100 sec. (fall time) |
Span Drift | ±0.5% full scale |
Temperature (English) Operating | 68°F to 86°F (Performance) or 32°F to 113°F (Operating) |
Temperature (Metric) Operating | 20°C to 30°C (Performance), 0°C to 45°C (Operating) |
Zero Noise | 1.0 ppb RMS (10 sec. averaging time), 0.5 ppb RMS (60 sec. averaging time),0.25 ppb RMS (300 sec. averaging time) |
Certifications/Compliance | ETL, CSA, UL, CE; U.S. EPA, European (TUV), MCERTS, EQSA-0486-060, UKCA |
Depth (English) | 23 in. |
Depth (Metric) | 584 mm |
Description | 43i Sulfur Dioxide Analyzer |
Detection Limit | < 0.5 ppb |
Height (English) | 8.62 in. |
Height (Metric) | 219 mm |
Interferences | < lower detectable limit except for the following: (EPA Levels) NO < 3 ppb, M-Xylene < 1 ppb, H2O < 3% of reading |
Measurement Range | Preset: 0 to 10, 20, 50, 100, 200, 500 and 1000 ppm; 0 to 20, 50, 100, 200, 500, 1000 and 2000 mg/m3; Custom: 0 to 0.05 to 100 ppm, 0 to 0.2 to 250 mg/m3; Extended: 0-0.05, 1, 2, 5, 10, 20, 50 and 100 ppm, 0-2, 5, 10, 20, 50, 100, 200, and 250 mg/m3 |
Mounting Options | Bench (standard), EIA, Retrofit |
Outputs | Selectable voltage, RS232/RS485, TCP/IP, 10 status relays, and power fail Indication (standard). 0-20 or 4-20 mA isolated current output (optional) |
Voltage | 100/115/220/240 V |
Weight (English) | 48 lb. |
Weight (Metric) | 21.8 kg |
Width (English) | 16.75 in. |
Width (Metric) | 425 mm |
Zero Drift | <1ppm/day |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (CNY) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
43I | Each | 43i Sulfur Dioxide Analyzer | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Key Features:
iSeries Advantage:
The Model 43i SO2 Analyzer is also available with an oxygen sensor module.
The Model 43i with Oxygen uses paramagnetic sensor technology to extend the possibilites of SO2 measurment, reading and reporting the concentration of oxygen in the sample stream up to 100%. Additionally, programming allows the user to correct the SO2 reading for the amount of oxygen in the sample.