MeltDoctor™ HRM Reagent Kit
Product Image
Applied Biosystems™

MeltDoctor™ HRM Reagent Kit

Applied Biosystems™ MeltDoctor™ HRM Reagent Kit provides individually packaged PCR components and the MeltDoctor™ HRM Dye required for high resolutionRead more
Have Questions?
Catalog NumberQuantity
44255571 kit
Catalog number 4425557
Price (CNY)
6,518.00
Each
Add to cart
Quantity:
1 kit
Price (CNY)
6,518.00
Each
Add to cart
Applied Biosystems™ MeltDoctor™ HRM Reagent Kit provides individually packaged PCR components and the MeltDoctor™ HRM Dye required for high resolution melting analysis. High Resolution Melting (HRM) analysis is a post-PCR analysis method used to identify genetic variation in nucleic acid sequences.
This kit includes:
• AmpliTaq Gold™ 360 DNA Polymerase which, when combined with AmpliTaq Gold™ 360 Buffer and 360 GC Enhancer, amplifies a vast range of DNA sequence contexts. AmpliTaq Gold™ 360 DNA Polymerase delivers 360° coverage for a full range of targets.
• GeneAmp™ dNTP Blend
• MeltDoctor™ HRM Dye, a stabilized form of the fluorescent SYTO™ 9 double-stranded nucleic acid stain developed by Molecular Probes
For Research Use Only. Not for use in diagnostic procedures.
Specifications
For Use With (Equipment)7500 Fast System, 7900HT Fast System
Genotyping TargetSNPs (Unknown or Numerous), Epigenetic Targets
PolymeraseAmpliTaq Gold 360 DNA Polymerase
Product LineMeltDoctor™
Product TypeHrm Reagent Kit
Quantity1 kit
Sample TypeDNA (Genomic), cDNA
TechniqueHRM (High Resolution Melting) Analysis, Mutation Scanning
Detection MethodHRM
For Use With (Application)Real Time PCR (qPCR)
GC-Rich PCR PerformanceHigh
Label or DyeHigh Resolution Melting (HRM), SYTO 9
PCR MethodqPCR
Unit SizeEach
Contents & Storage
This kit includes: AmpliTaq Gold™ 360 DNA Polymerase (2 x 50 μL, each at 5 U/μL), AmpliTaq Gold™ 360 Buffer, 360 GC Enhancer, GeneAmp™ dNTP Blend, and MeltDoctor™ HRM Dye (20x). The kit provides sufficient materials for 250 20-μL reactions when using 2 U AmpliTaq Gold 360 DNA Polymerase per reaction.

Store at -15° to -25°

Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

Frequently asked questions (FAQs)

How long should the amplicon be for HRM analysis?

We recommend to use 50-250 bp long PCR amplicons. Typically, shorter amplicons can distinguish the genotypes for a SNP better, especially for Type III and Type IV SNPs. This is simply because a single base variation affects the melting behavior of a 100 bp amplicon stronger than of a 500 bp amplicon, for example. In longer fragments, the risk of covering multiple mutations is also increased.

What can be used as positive control reactions in HRM analysis?

Positive control reactions should contain template DNA with a known sequence. In SNP genotyping experiments, this could be a sample with a known genotype. Positive control(s) for all genotypes should be included where possible to serve as a reference in melting curve comparison and assigning genotypes for test samples. In mutation scanning experiments, a sample with a wild type sequence could serve as a positive control. The controls should preferably have the same DNA concentration as their corresponding test samples. Control DNA should also be eluted and/or diluted in the same buffer as the samples.

In HRM analysis, when is it better to use a 3-step cycling protocol rather than a 2-step protocol?

A 3-step cycling protocol is recommended for the analysis of complicated (especially Type IV SNP) targets, amplicons longer than 200 bp, and amplicons with a primer annealing temperature that is less than 60 degrees C.

The HRM software will not accept my calibration file. What is wrong?

Check that there are no outliers on the plate. You cannot omit any wells on the HRM calibration plate.

I have a 7900HT Fast Real-Time PCR System, and cannot open the data file in HRM software. What could be causing this?

There are a few possibilities. First, make sure the HRM Software version is v2.0.1, and the 7900HT Fast Real-Time PCR System software version is v2.3 or above. Second, check that the run method used was as recommended in the HRM protocol; make sure the ramp rate for the dissociation stage is 1%. Then try to open the calibration file from the HRM Software; if it does not open, the calibration file is defective. The defects could be due to a bad calibration plate or instrument uniformity issue.