6000 Continuous Monitoring System for Stationary Pollution Source VOC Emission
6000 Continuous Monitoring System for Stationary Pollution Source VOC Emission
Actual product may vary
6000 Continuous Monitoring System for Stationary Pollution Source VOC Emission
6000 Continuous Monitoring System for Stationary Pollution Source VOC Emission
Thermo Scientific™

6000 Continuous Monitoring System for Stationary Pollution Source VOC Emission

6000 Continuous Monitoring System can monitor volatile Organic Compound Monitoring Device: Measure CH4/NMHC, Benzene, Toluene, Xylene and other Benzene series, customized component VOCs.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberDescription
5031800003VOC6000 Analyzer (BTEX)
5031100001VOC6000 Analyzer (CH4/NMHC)
5031300002VOC6000 Analyzer (Benzene/Toluene/Xylen)
Catalog number 5031800003
Price (CNY)
-
Request A Quote
Description:
VOC6000 Analyzer (BTEX)
6000 Continuous Monitoring System can monitor volatile Organic Compound Monitoring Device: Measure CH4/NMHC, Benzene, Toluene, Xylene and other Benzene series, customized component VOCs. With design and composition based on thermal state measurement, the analyzer can accept sample gas temperature of up to 220°C. Speedy analysis, which can meet the requirements of both compliance continuity and process control of treatment equipment.

With design and composition based on thermal state measurement, the analyzer can accept sample gas temperature of up to 220°C.

Component analysis can be realized

THC/CH4/NMHC

Benzene series

Other customized characteristic factors

Range width: 0-50ppm/500ppm/5000ppm/5%/50% (in methane)

Speedy analysis, which can meet the requirements of both compliance continuity and process control of treatment equipment.

Calibration

  • The system calibration conforms to the international regulations and can ensure the accuracy of the whole analysis system.
  • The instrument calibration verification provides convenience for VOCs monitoring system maintenance.
  • Fast sample displacement ensures real-time monitoring
  • Sample update rate: 1-6L/min.
Specifications
Auxiliary Gas
Fuel gas: Hydrogen, 30 ml/min, 0.2MPa, Purity > 99.999%, THC< 0.1 ppm
Combustion-supporting gas: Air, pure, oil-free and water-free, 300 ml/min, 0.2MPa,THC< 0.1 ppm
Carrier gas: Nitrogen, pure, oil-free and water-free, 60 ml/min, 0.2MPa, THC<0.1 ppm
Zero calibration gas: Nitrogen, pure, oil-free and water-free, 0.2MPa, THC< 0.1 ppm, (carrier gas is nitrogen)
Range calibration gas: Hydrocarbons of known concentration equilibrated in nitrogen (nitrogen as carrier gas), inflow pressure is 0.1MPa
Pipe purge gas: Air, pure, oil-free and water-free, 10 L/min, 0.2MPa, THC< 1 ppm
Calibrationdaily - weekly, can be set by users
Communication Ports1 x RS-232, 1 x USB, 2 x network ports (optional: 4-20 mA)
DescriptionVOC6000 Analyzer (BTEX)
Electrical RequirementsAnalysis system: AC 220V, 50/60 Hz, 2 kW (Including system cabinet +sampling probe)
Sampling pipe: AC 220V, 50/60 Hz, 3.25 kW (heat tracing pipe of 50m length)
Measurement Range0-50ppm/500ppm/5000ppm/5%/50% in methane
OutputsInstrument calibration
verification/instrument
calibration/instrument
maintenance/instrument
abnormality/hydrogen cutoff
Sampling Flow and Control100-1000 mL/min
Measurement MethodGC-FID, Hydrogen Flame Ionization Method
Temperature (English) Operating32°F to 113°F, ≤85% RH (no condensation); Sample temperature: 59°F to 428°F, 85% RH (no condensation)
Temperature (Metric) Operating0°C to 45°C, ≤85% RH (no condensation), Sample temperature: 15°C to 220°C, 85% RH (no condensation)
Unit SizeEach