Immuno Clear Standard Modules, Max. working volume: 330μL
Immuno Clear Standard Modules, Max. working volume: 330μL
Immuno Clear Standard Modules, Max. working volume: 330μL
Immuno Clear Standard Modules, Max. working volume: 330μL
Immuno Clear Standard Modules, Max. working volume: 330μL
Thermo Scientific™

Immuno Clear Standard Modules, Max. working volume: 330μL

Immuno Clear Standard Modules feature Nunc™, Immulon™ and Microtiter™ module plates that are developed for ELISA techniques and fit standard equipment.
Have Questions?
Catalog NumberSurface Treatment
6404TS
also known as 6404
Immulon 4 HBX
Catalog number 6404TS
also known as 6404
Price (CNY)
4,418.75
Case of 320
Add to cart
Surface Treatment:
Immulon 4 HBX
Price (CNY)
4,418.75
Case of 320
Add to cart

Thermo Scientific™ Immuno Clear Standard Modules feature Nunc™, Immulon™ and Microtiter™ module plates that are developed for ELISA techniques and fit standard equipment. Their format provides flexible use of components with small sample sizes. The modules offer lot-to-lot reliability, well-to-well reproducibility and are backed by industry-leading quality standards and certifications.

Thermo Scientific standard modules are strip plates with solid modules that can be easily inserted and removed from their frame. This enhances the use of the plate with smaller sample sizes.

  • Several strip formats: 8-well strip, 12-well strip, 16-well strip (two columns of 8 wells)
  • Several well shapes: flat bottom, C bottom (radius edge), U shape wells, StarWells (wells have fins to increase the surface area and enhance performance)
  • Several surfaces to maximize assay performance
  • Modules remain in frame when inverted
  • Stackable frame marked for lid orientation
  • Polystyrene wells in polyethylene frame
  • Ext. Dim.: 128 × 86mm

Choice of Surface

  • PolySorp™, Immulon 1B, and Universal Binding (UB) for adsorption of hydrophobic molecules
  • Medisorp™ and Immulon 2HB are slightly hydrophilic and bind a diverse range of biomolecules
  • MaxiSorp™, Immulon 4 HBX, and Enhanced Binding(EB) are hydrophilic and ideal for antibody sandwich assays
  • MultiSorp™ are very hydrophilic and works well for glycans and water soluble proteins

Ordering Information:

Free-standing modules. Cat. No. 95029440 and 464394 are certified. Frames and modules available separately. Sealing tape and strip caps are available. Color-coded modules are available on request. Contact your Customer Service or Sales Representative for further details.

Specifications
Binding PropertyHydrophilic
Binding TypeAdsorption
BreakapartBreakable Strips
Certifications/ComplianceCertified for adsorption of IgG; CV of <5% between wells
CertifiedYes
Detection MethodColorimetric
No. per Case320
No. per Pack320
Packaging320 Pk., 320 Cases
Plate BlockingNone
Product TypeUnframed – Use Frame 6604
Target MoleculeAntibodies (Glycoproteins)
Volume (Metric) Working330 μL
Well DesignF12
ColorClear
FormatStrip Plate
MaterialPolystyrene
No. of Wells96
Surface TreatmentImmulon 4 HBX
Volume (Metric) Well380 μL
Well ShapeRound, Flat Bottom (F-well)
Unit SizeCase of 320

Frequently asked questions (FAQs)

What frames do you recommend for your Immuno Clear Standard Modules?

We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

Which Nunc immunodiagnostic passive surface should I choose: PolySorp, MediSorp, MaxiSorp, or MultiSorp?

Our passive immunodiagnostic surfaces are based on a series of treatments that modify the polystyrene surface to different final levels of hydrophilicity. Selection of one of these surfaces for ELISA development should be based on the characteristics of the biomolecule you seek to immobilize. PolySorp is fairly hydrophobic and should be used for biomolecules that have hydrophobic domains, e.g., lipids, lipoproteins, and large proteins. MediSorp is slightly hydrophilic and can be used for biomolecules with hydrophilic and hydrophobic properties, e.g., medium-to-large proteins such as albumin, or amphiphilic biomolecules such as LPS. MaxiSorp is quite hydrophilic, optimized for binding of IgG (and any other molecule with similar characteristics) and thus is a popular choice for sandwich ELISA and similar protocols. MultiSorp is very hydrophilic, and in turn will immobilize very hydrophilic biomolecules such as glycoproteins. Some optimization will always be necessary, and in many cases screening for binding optimization may involve a few surface types.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.

What is the difference between a certified and an uncertified immunodiagnostic plate, e.g., Cat. No. 439454 vs. 442404?

There is no difference in the manufacturing process. Certified plates are performance tested (using an antibody binding protocol) during quality control, whereas uncertified plates are not. This test is expensive for us to perform, so we offer the uncertified version at cost savings customers for whom antibody binding testing results are not critical.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.