Applied Biosystems™

TaqMan™ QK Platinum 1-Step Multiplex Master Mix

Catalog number: A54080
Applied Biosystems™

TaqMan™ QK Platinum 1-Step Multiplex Master Mix

Catalog number: A54080
Catalog Number
A54080
Unit Size
200 reactions
Price (CNY)
Price: 2,909.00
Online offer: 1,439.96
(ends 30-Jun-2024)
Your price:
Availability
-
Quantity
Catalog Number
Unit Size
1000 reactions
Price (CNY)
Price: 12,874.00
Online offer: 6,370.00
(ends 30-Jun-2024)
Your price:
Availability
-
Quantity
Catalog Number
Unit Size
5000 reactions
Price (CNY)
Price: 56,000.00
Online offer: 27,720.00
(ends 30-Jun-2024)
Your price:
Availability
-
Quantity
Catalog NumberUnit SizePrice (CNY)AvailabilityQuantity
A54080200 reactions
Price: 2,909.00
Online offer: 1,439.96
(ends 30-Jun-2024)
Your price:
-
A540811000 reactions
Price: 12,874.00
Online offer: 6,370.00
(ends 30-Jun-2024)
Your price:
-
A540825000 reactions
Price: 56,000.00
Online offer: 27,720.00
(ends 30-Jun-2024)
Your price:
-
Product Overview
Figures
Videos
Recommendations
Recommendations
Documents
FAQ
Citations & References
Additional Information
Recommendations
TaqMan QK Platinum 1-Step Multiplex Master Mix is designed for rapid, multiplex, high-sensitivity real-time quantitative RT-PCR detection with high-quality results for even complex samples. This master mix contains UDG enzyme to help prevent crossover contamination. The enzyme master mix and buffer are provided in concentrated format, which allows for the addition of more sample to each reaction, increasing sensitivity in even small reactions. The separate enzyme master mix and buffer facilitate the optimization of reaction conditions and are ideal for molecular diagnostic applications.

Features of TaqMan QK Platinum 1-Step Multiplex Master Mix include:
High sensitivity—10X enzyme master mix and 5X buffer help amplify RNA and DNA targets with increased sensitivity
Multiplexed targets—can detect up to five targets including exogenous and endogenous controls
Ease of optimization—enzyme and buffer are separated
For complex samples—high-quality detection of crude samples such as saliva and cells
Wide dynamic range—accurately measure up to six logs of dynamic range
High batch-to-batch consistency—production process follows ISO 9001 quality management system to help ensure consistency between production batches

High sensitivity
TaqMan QK Platinum 1-Step Multiplex Master Mix has been optimized for high-sensitivity detection of low-abundance targets. Concentrated enzyme master mix and buffer (10X and 5X, respectively) allow larger sample volumes to be added to standard reactions for more accurate quantitation of low-abundance samples. At the same time, it allows the construction of smaller reactions and is compatible with fast cycling protocols. As few as five copies of RNA template have been detected in a 20-μL reaction (see figure below).

Multiplex targets
TaqMan QK Platinum 1-Step Multiplex Master Mix can accommodate up to five channels of simultaneous detection. A figure below shows a linear regression result of a 5-plex detection reaction of ACADM, APOE, GAPDH, RNaseP, and an exogenous internal positive control (IPC) of human RNA, with an R2 value greater than 0.98.

Easy to optimize
TaqMan QK Platinum 1-Step Multiplex Master Mix separates the enzyme master mix and buffer, which is more conducive to optimizing the reaction conditions according to different targets and sample types.

Suitable for complex samples
The buffer components and proprietary additives in TaqMan QK Platinum 1-Step Multiplex Master Mix have been optimized to ensure reliable results even for complex samples such as saliva and crude cell extracts (see figure below).

Wide dynamic range
TaqMan QK Platinum 1-Step Multiplex Master Mix can yield a dynamic range of up to six logs (see figure below) and shows a comparable or better range of detection of various targets compared to other master mixes (see figure below).

High batch-to-batch consistency
The production process of TaqMan QK Platinum 1-Step Multiplex Master Mix follows the ISO 9001 quality management system, which helps ensure the traceability of the production process and establishment of quality control points from raw material procurement to product release, helping to produce high batch-to-batch consistency of the master mix (see figure below).

For Research Use Only. Not for use in diagnostic procedures.

Specifications

Detection Method
Primer-probe
Form
Liquid
Format
Tubes
PCR Method
1-step RT-qPCR
Polymerase
Hot start Taq DNA Polymerase
Reaction Speed
Fast or Standard
For Use With (Equipment)
7500 Fast System, 7500 System, QuantStudio™ 12k Flex, QuantStudio™ 3,QuantStudio™ 5,QuantStudio™ 6 Flex,QuantStudio™ 7, ViiA™ 7 System
Passive Reference Dye
ROX (Non pre-mixed)
Product Line
TaqMan™
Product Type
1-Step Master Mix
Reverse Transcriptase
M-MLV
Shipping Condition
Dry Ice
For Use With (Application)
Gene Expression, Virus Detection
Hot Start
Built-In Hot Start
No. of Reactions
200 Reactions
Sample Type
Total RNA, Viral DNA, Viral RNA, mRNA

Contents & Storage

Contains three tubes, enough for 200 reactions.

• 1 x 1 mL tube of 5X TaqMan RT-PCR Buffer, including dNTP (dUTP)
• 1 x 500 μL tube of 10X TaqMan Enzyme Master Mix, including hot start Taq DNA polymerase, thermostable MMLV enzyme ribonuclease inhibitor, thermosensitive UNG
• 1 x 100 μL vial of 50X ROX Reference Dye

Store at –20°C.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text