Thermo Scientific™

Triton™ Series Multicollector Thermal Ionization Mass Spectrometer

Catalog number: IQLAAEGAASFAFYMAMV
Thermo Scientific™

Triton™ Series Multicollector Thermal Ionization Mass Spectrometer

Catalog number: IQLAAEGAASFAFYMAMV

Extract high-precision isotope ratio information from your samples with the Thermo Scientific™ Triton™ Series Multicollector Thermal Ionization Mass Spectrometer (TIMS).

The Thermo Scientific™ Triton™ XT TIMS integrates the established field-proven technologies from the Triton Series instruments with the latest developments in technology for isotope ratio analysis from Thermo Fisher Scientific™.

 
Catalog Number
IQLAAEGAASFAFYMAMV
Unit Size
Each
Description
Triton Plus
Includes
System only
Price (CNY)
Full specifications
TypeTIMS
DescriptionTriton Plus
IncludesSystem only
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Triton XT
Includes
1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Price (CNY)
Full specifications
TypeTIMS
DescriptionTriton XT
Includes1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeDescriptionIncludesPrice (CNY)
IQLAAEGAASFAFYMAMVFull specifications
EachTriton PlusSystem onlyRequest A Quote
TypeTIMS
DescriptionTriton Plus
IncludesSystem only
Unit SizeEach
0726203Full specifications
EachTriton XT1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).Request A Quote
TypeTIMS
DescriptionTriton XT
Includes1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
Showing 2 of 2

The result of over two decades of development

The Thermo Scientific™ Triton XT™ TIMS is the pinnacle of over two decades of continuous development, combining outstanding technologies such as:

  • 1013Ω Amplifier Technology: extending the lower limits of the ultimate detector
  • Retarding Potential Quadrupole Lenses (RPQ): for the highest abundance sensitivity allowing high precision of extreme isotope ratios
  • Multi-ion counting (MIC) packages: dedicated for specific nuclear and geochronology applications
  • Stable and linear SEM and then CDD ion counters: for the smallest sample amounts and lowest abundance isotopes
  • High-performance Faraday cups: to guarantee uniform response and long lifetime
  • High stability thermal ionization source: characterized by a very small kinetic energy spread of the ions and optimized for maximum ion transmission for both single and double filament techniques
  • Reliable moveable collector array: brings up to 9 Faraday cups into precise alignment with ion beams of different dispersions. With a mass range to cover static Li measurements, that is extendable to cover static Ca
  • Virtual amplifier: allows cancellation of gain factor uncertainties through amplifier rotation, so that low ppm external reproducibility can be achieved using efficient static measurements