GeneJET Endo-Free Plasmid Maxiprep Kit
Invitrogen17万+抗体限时买二赠一,靶点广,灵活用!
GeneJET Endo-Free Plasmid Maxiprep Kit
Thermo Scientific™

GeneJET Endo-Free Plasmid Maxiprep Kit

The Thermo Scientific GeneJET Plasmid Maxiprep Kit utilizes silica-based membrane technology in the form of convenient spin column.
Have Questions?
Catalog NumberQuantity
K086110 Preps
Catalog number K0861
Price (CNY)
-
Quantity:
10 Preps

Thermo Scientific GeneJET Endo-Free Plasmid Maxiprep Kit is a fast, convenient, and efficient system for the large scale purification of endotoxin-free plasmid DNA. Endotoxins are major contaminants found in plasmid DNA preparations. For transfection of sensitive cell lines endotoxins are a major problem. The same applies to in vivo transfection as endotoxins can elicit strong immune responses. Thermo Scientific GeneJET Endo-Free Plasmid Maxiprep Kit is designed to reduce endotoxin level to <0.1 EU/μg of plasmid DNA. The kit utilizes a silica-based membrane technology in the form of convenient spin columns.

Each preparation recovers up to 1000 μg of high copy plasmid DNA from 350 mL of recombinant E. coli cultures that can be used in a wide variety of molecular biology procedures such as transfection of sensitive cells (e.g. Huh-7), in vivo transfection, transformation, restriction endonuclease digestion, automated sequencing, and in vitro transcription.

Highlights

  • Pure—free of endotoxins plasmid DNA suitable for transfection of sensitive cells
  • Efficient—plasmid recovery resulting in high DNA yields
  • Fast—isolation of high quality plasmid DNA in less than 60 minutes
  • Convenient—spin column format, centrifuge or vacuum protocol

Applications

Isolated plasmid DNA is suitable for all conventional molecular biology procedures, including:

  • Transfection of sensitive cell lines
  • FastDigest restriction enzyme digestion
  • In vivo transfection
  • Automated fluorescent sequencing
  • PCR
  • Cloning
  • Transformation
  • In vitro transcription

Includes

  • Resuspension Solution
  • Lysis Solution
  • Neutralization Solution
  • Endotoxin Binding Reagent
  • Wash Solution I (concentrated)
  • Wash Solution II (concentrated)
  • RNase A Solution
  • Elution Buffer (10 mM Tris-HCl, pH 8.5)
  • GeneJET Endo-Free Maxi Purification Columns & Collection Tubes (50 mL, blue-capped)
  • GeneJET Endo-Free Maxi Filtration Columns & Collection Tubes (50 mL, white-capped)

Hazardous: No

Quality Control:

  • The GeneJET Plasmid Maxiprep Kit is qualified by isolating high copy number plasmid DNA from 250 mL of overnight E. coli culture (OD600 = 2) grown in LB medium following the protocol outlined in the manual.
  • The kit passes QC requirements if the purified plasmid DNA has an A260/280 ratio between 1.8 and 1.9 and a dominant band of supercoiled plasmid DNA is observed after agarose gel electrophoresis.
  • The functional quality of the plasmid DNA is evaluated by digestion with restriction endonucleases.
For Research Use Only. Not for use in diagnostic procedures.
Specifications
Column TypeSpin Column
Concentration400 ng/μL
For Use With (Application)Real-Time Quantitative PCR (qPCR), Transfection, Cloning, Sequencing, In Vitro Transcription, Transformation, Nucleic Acid Labeling, PCR
High-throughput CompatibilityNot High-throughput Compatible (Manual)
No. of Reactions10 Preps
Prep Scale> 200 μg (Large-Scale) Plasmid DNA
Product LineGeneJET
Product TypeEndo-Free Plasmid MaxiPrep Kit
Quantity10 Preps
Sample TypeBacteria
ScaleMaxi
TargetPlasmid DNA
Test Time60 min.
FormatSpin Column
Isolation TechnologySilica Column
Unit SizeEach

Frequently asked questions (FAQs)

Can I use water instead of Elution Buffer in the elution step of GeneJET and MagJET nucleic acid purification kits?

We would highly recommend using the provided Elution Buffer in the elution step for best results. You may use nuclease-free water; however, it may affect the yield of the nucleic acids during purification and their stability during storage.

Are MagJET and GeneJET plasmid purification kits compatible with EndA+ bacterial strains?

Yes, MagJET and GeneJET Plasmid DNA Purification Kits are suitable for plasmid DNA purification from EndA+ strains. Please refer to the specific kit protocol for details. GeneJET Plasmid Miniprep Kit requires Wash Solution I (Cat. No. R1611, not included in the kit) for EndA+ strains.

Can I use a vacuum manifold with GeneJET kits?

The GeneJET spin columns are compatible with vacuum manifolds of standard size (e.g. Qiagen, Sigma-Aldrich, Promega). However, not all GeneJET kits are supported with a vacuum protocol. Please refer to the particular kit protocol for the detailed procedure.

At what temperature should I perform centrifugation steps in the GeneJET kits?

We recommend performing centrifugation steps at room temperature when the temperature is not specified.

Are GeneJET spin columns or MagJET magnetic beads available separately?

No, we do not offer GeneJET columns or MagJET magnetic beads separately at this time.