North2South™ 杂交严格洗涤缓冲液 (2X)
North2South™ 杂交严格洗涤缓冲液 (2X)
Thermo Scientific™

North2South™ 杂交严格洗涤缓冲液 (2X)

Thermo Scientific North2South 杂交严格洗涤缓冲液 (2X),与 North2South 化学发光杂交和检测试剂盒配合使用。相关产品North2South™完整的生物素随机引物标记和检测试剂盒North2South™ 化学发光杂交和检测试剂盒North2South™ 化学发光底物,适用于了解更多信息
Have Questions?
货号数量
37555375 mL
货号 37555
价格(CNY)
2,591.00
Each
添加至购物车
数量:
375 mL
请求批量或定制报价
价格(CNY)
2,591.00
Each
添加至购物车
Thermo Scientific North2South 杂交严格洗涤缓冲液 (2X),与 North2South 化学发光杂交和检测试剂盒配合使用。

相关产品
North2South™完整的生物素随机引物标记和检测试剂盒
North2South™ 化学发光杂交和检测试剂盒
North2South™ 化学发光底物,适用于 HRP
North2South™ 杂交缓冲液
仅供科研使用。不可用于诊断程序。
规格
缓冲液洗涤缓冲液
最大浓度2X
产品线North2South
产品类型洗涤缓冲液
数量375 mL
Unit SizeEach
内容与储存
储存在原容器中,置于干燥、阴凉且通风良好的区域内,避免阳光直照,在以下温度之间:2 至 8°C。

常见问题解答 (FAQ)

Can I strip and re-probe a blot made used with the North2South Chemiluminescent Hybridization and Detection Kit?

Yes. The most common procedure for stripping DNA blots is to wash the blot 3 x 5 minutes with boiling 0.1% SDS. An additional alkaline wash of 3 x 5 minutes with 0.4 N NaOH, 0.1% SDS may also work for DNA blots. The blots must be neutralized in TE buffer after this wash method. RNA blots are best washed with 0.1 % SDS, 3 x 5 minutes, at 75-85°C. Commercial stripping buffers are also available. Stripped blots should be kept wet until re-probed by storage in TE buffer at 4°C. Blots may be stripped and re-probed several times.

Is non-specific DNA added to the blocking buffer or hybridization buffers in the North2South Chemiluminescent Hybridization and Detection Kit?

Yes. The hybridization buffers for the North2South Chemiluminescent Hybridization and Detection Kit contain single stranded nucleic acids used to block the membrane during the pre-hybridization and hybridization procedures. The addition of more single stranded DNA or RNA is not needed.

Can I order the components of the North2South Kit Chemiluminescent Hybridization and Detection separately?

Yes. Certain components are offered separately: Cat. No. 17295, North2South Chemiluminescent Substrate for HRP, Cat. No. 37549, North2South Hybridization Buffer, Cat. No. 37555, North2South Hybridization Stringency Wash Buffer (2X).

Can I use a CCD camera to record the results with the North2South Chemiluminescent Hybridization and Detection Kit?

Yes. A CCD Camera will work with the North2South Chemiluminescent Hybridization and Detection Kit (Cat. No. 17097). The results will depend on the quality of the chip in the camera. The peak light emission for chemiluminescence is at 425 nm. Traditional phosphorescence imagers do not work for chemiluminescence.

Can I use the North2South Chemiluminescent Hybridization and Detection Kit to perform colony lifts?

Yes. Standard colony lift protocols will work using a biotinylated probe. However, care should be taken to completely remove any residual bacterial debris or agarose from the filters, as this will cause high background signals. Non-specific speckling may be eliminated by centrifugation of the streptavidin-HRP conjugate in a bench-top microcentrifuge for several minutes at maximum speed before adding it to the hybridization buffer.