适用于 CTS™ RoTEA™ 一次性套件的无菌鲁尔接头
Product Image
Gibco™

适用于 CTS™ RoTEA™ 一次性套件的无菌鲁尔接头

Gibco CTS Rotea 一次性套件是 Gibco CTS Rotea 逆流离心系统的组成部分。每个套件可执行多种细胞处理步骤,适用于洗涤和浓缩、分离了解更多信息
Have Questions?
货号数量
A5011010 x 32 Connectors
货号 A50110
价格(CNY)
5,703.00
Each
添加至购物车
数量:
10 x 32 Connectors
价格(CNY)
5,703.00
Each
添加至购物车
Gibco CTS Rotea 一次性套件是 Gibco CTS Rotea 逆流离心系统的组成部分。每个套件可执行多种细胞处理步骤,适用于洗涤和浓缩、分离、隔离等。一次性套件方便灵活进行工艺开发并轻松支持商业规模生产。每个套件均兼容无菌鲁尔接头或热焊接。

这些无菌鲁尔接头与套件配合使用,可连接各袋,无需管焊机。每包接头都具有双层包装并经过伽马射线辐照。该产品附带10包接头。每包装有以下鲁尔接头:
•8个倒钩鲁尔母接头
• 8个倒钩鲁尔公接头
•8个鲁尔凹盖
• 8个鲁尔插头

规格
数量10 x 32 Connectors
产品线CTS Rotea
制冷型
Unit SizeEach

常见问题解答 (FAQ)

Do you have a calculation formula that allows us to estimate the max feed flow rate/processing time for the CTS Rotea System, depending on the cell diameter?

The Rotea Protocol Builder Software, which includes the Rotea Process Model and Simulator, is available for download from the Rotea website. Common cell types are already pre-loaded into the software, and custom cells can also be created. The CTS Rotea System can separate cells that have at least 4 µm difference in diameter. Thermo Fisher Scientific recommends that customers use protocol optimization and workflow validation testing to meet their process needs. Please visit our webpage (www.thermofisher.com/rotea) to see if the CTS Rotea System will work for your cell type, or submit a request for more information using our demo form (https://www.thermofisher.com/us/en/home/global/forms/life-science/rotea-counterflow-centrifugation-system-cell-therapy.html) to get connected with a Business Development Manager.

Are there plans for incorporating magnetic bead selection in the CTS Rotea System or other ways of automating magnetic bead selection?

Thermo Fisher Scientific strives to provide a catalog of tools to support our diverse customers' needs. If magnetic bead separation using the CTS Rotea System is of interest, Thermo Fisher Scientific recommends that customers use protocol optimization and workflow validation testing to meet their process needs.

How does cell processing with Ficoll medium compare to using the CTS Rotea System?

Ficoll medium has many shortcomings and often does not scale well for cGMP manufacturing. Rotea PBMC isolation protocol takes less time and has been demonstrated to be capable of providing higher cell recovery compared to Ficoll medium. Thermo Fisher Scientific recommends that customers use protocol optimization and workflow validation testing to meet their process needs.

What is the best cryopreservative to use with the CTS Rotea System?

The CTS Rotea single-use kits are manufactured with DEHP-free PVC. Extractables and Leechables testing was conducted with 20% DMSO for up to 15 min. The CTS Rotea System has not been validated for fill-finish applications. Thermo Fisher Scientific recommends that customers use protocol optimization and workflow validation testing to meet their process needs.

Have you performed final formulation on the CTS Rotea System directly into cryopreservation media?

The CTS Rotea System has been demonstrated to be capable of washing cells from cryoprotectant into media and the reverse. The CTS Rotea System has not been validated for fill-finish applications. Thermo Fisher Scientific recommends that customers use protocol optimization and workflow validation testing to meet their process needs