适用于 E-Gel™ 琼脂糖凝胶的 iBright™ 系统托盘适配器
适用于 E-Gel™ 琼脂糖凝胶的 iBright™ 系统托盘适配器
Invitrogen™

适用于 E-Gel™ 琼脂糖凝胶的 iBright™ 系统托盘适配器

设计用于优化 Invitrogen E-Gel 琼脂糖凝胶的图像捕获的成像附件。
Have Questions?
更改视图buttonViewtableView
货号产品类型
A56599E-Gel 托盘适配器,48/96孔
A56600E-Gel 托盘适配器,11/22孔
货号 A56599
价格(CNY)
1,832.00
Each
添加至购物车
产品类型:
E-Gel 托盘适配器,48/96孔
价格(CNY)
1,832.00
Each
添加至购物车
适用于 E-Gel 琼脂糖凝胶的 Invitrogen iBright 托盘适配器是一种成像附件,设计用于优化 Invitrogen E-Gel 琼脂糖凝胶的图像捕获。

适用于 E-Gel 琼脂糖凝胶的 Invitrogen iBright 托盘适配器的特性包括:
• 底部组件可使 iBright 透射盒上的 E-Gel 琼脂糖凝胶居中,以方便优化缩放
• 顶部组件覆盖 E-Gel 盒上的标签和条形码,以减少图像捕获时的杂散光并改善样品信号优化
• 兼容所有 iBright 型号(CL750、CL1000、CL1500、FL1000 和 FL1500)
• 兼容11至96孔 E-Gel 琼脂糖(货号:A56600 [对于11/22孔]、货号:A56599 [对于48/96孔])

仅供科研使用。不可用于诊断程序。
规格
适用于(应用)化学发光 Western 印迹成像、DNA 凝胶成像、蛋白凝胶成像
产品线iBright
数量1个适配器
运输条件室温
产品类型E-Gel 托盘适配器,48/96孔
Unit SizeEach

常见问题解答 (FAQ)

Why do the iBright Imaging Systems use green LED illumination for DNA imaging?

The iBright Imaging Systems utilize a transilluminator based on green LEDs, which effectively excite popular DNA dyes such ethidium bromide and SYBR Green dye and offer several additional benefits:

- No harmful UV rays: While UV light effectively excites many fluorescent dyes and stains, UV light is a health hazard. Further, prolonged exposure to UV light can damage DNA samples, and compromise the integrity of samples to be used for downstream applications, such as subcloning.
- No mercury waste: UV transilluminator bulbs may contain mercury, a hazardous substance, and therefore require special care for handling and disposal.
- Longer lifetime: LED bulbs have a substantially longer real-time life than fluorescent UV bulbs, which can add up to considerable cost savings over the lifetime of the instrument.

For additional information on iBright functionality, visit this page.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

What sample types can I image with the iBright CL750 Imaging System?

The iBright CL750 Imaging System supports imaging of chemiluminescent western blots, colorimetric and fluorescent stained gels, and nucleic acid gels. It can also be used to image GFP- and crystal violet-stained colony plates.

For additional information about these applications or to learn more about the three iBright model capabilities, visit this page.

To speak with a representative about the iBright imager or request a quote or demo, please fill out this form.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

What sample types can I image with the iBright CL1500 Imaging System?

The iBright CL1500 Imaging System supports a wide range of applications including the following:

Protein gel: colorimetric staining of gels (e.g., Coomassie, silver) and membranes (e.g., Ponceau S, Thermo Scientific Pierce Reversible Protein Stain), fluorescent staining of gels (e.g., Invitrogen SYPRO Ruby stain)

Nucleic acid gel: ethidium bromide and Invitrogen SYBR stains; imaging of E-Gels and hand pour gels is supported

Chemiluminescent western blot: chemiluminescence using all popular HRP and AP substrates (e.g., Thermo Scientific SuperSignal and Invitrogen WesternBreeze substrates)

Additional applications: colony counting for GFP, crystal violet, and blue/white colonies; TLC plates, and leaf sections

For additional information about these applications or to learn more about the three iBright model capabilities, visit this page.

To speak with a representative about the iBright imager or request a quote or demo, please fill out this form.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

What sample types can I image with the iBright FL1500 Imaging System?

The iBright FL1500 Imaging System provides maximum application support including up to 4-channel multiplex western blot imaging. See the list below for more details:

Protein gel: colorimetric staining of gels (e.g., Coomassie, silver) and membranes (e.g., Ponceau S, Thermo Scientific Pierce Reversible Protein Stain), fluorescent staining of gels (e.g., Invitrogen SYPRO Ruby stain)

Nucleic acid gel: ethidium bromide and Invitrogen SYBR stains; imaging of E-Gels and hand-poured gels is supported

Chemiluminescent western blot: chemiluminescence using all popular HRP and AP substrates (e.g., Thermo Scientific SuperSignal and Invitrogen WesternBreeze substrates)

Fluorescent western blot: fluorescence with popular RGB (visible range) and near-IR fluorophores (e.g., Invitrogen Alexa Fluor and Alexa Fluor Plus conjugates)

Additional applications: colony counting for GFP, crystal violet, and blue/white colonies; TLC plates, and leaf sections

For additional information about these applications or to learn more about the three iBright model capabilities, visit this page.

To speak with a representative about the iBright imager or request a quote or demo, please fill out this form.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.