CellROX™ Green 试剂(用于氧化应激检测)
Invitrogen17万+抗体限时买二赠一,靶点广,灵活用!
CellROX™ Green 试剂(用于氧化应激检测)
Invitrogen™

CellROX™ Green 试剂(用于氧化应激检测)

CellROX™ Green 试剂是一种用于测量活细胞氧化应激的新型荧光探针。这种细胞可透过性染料在还原状态时发出弱荧光,经活性氧簇 (ROS) 氧化后,与 DNA 结合发出亮绿色荧光,最大吸收/发射波长 ∼485/520 nm了解更多信息
Have Questions?
货号数量
C104445 x 50 μL
货号 C10444
价格(CNY)
6,058.00
飞享价
Ends: 31-Dec-2025
8,159.00
共减 2,101.00 (26%)
Each
添加至购物车
数量:
5 x 50 μL
价格(CNY)
6,058.00
飞享价
Ends: 31-Dec-2025
8,159.00
共减 2,101.00 (26%)
Each
添加至购物车
CellROX™ Green 试剂是一种用于测量活细胞氧化应激的新型荧光探针。这种细胞可透过性染料在还原状态时发出弱荧光,经活性氧簇 (ROS) 氧化后,与 DNA 结合发出亮绿色荧光,最大吸收/发射波长 ∼485/520 nm。本试剂与甲醛固定兼容,清洗后仍然保留荧光信号,可与其他兼容染料和抗体联用。

CellROX™ Green 试剂可与各种平台兼容,如传统的荧光显微镜、高内涵筛选 (HCS)、流式细胞仪和基于微孔板的荧光分析或高通量筛选 (HTS)。本试剂也可与我们的 FLoid™ 细胞成像系统、Tali™ 成像型多色细胞分析仪和 Attune™ 流式细胞仪等多种台式仪器兼容。

此外,CellROX™ Green 试剂:

•与其他活细胞染料、抗体和表达 RFP 的细胞兼容
• 以稳定的即用型 DMSO 溶液形式提供,具有简单的免洗方案,与荧光显微镜检查的标准工作流程兼容
• 以 5 个一次性使用的样品瓶提供,所含总试剂量足够用于五个 96 孔板或 100 个盖玻片反应

由于活性氧簇 (ROS) 的生成和细胞清除活性氧簇的能力之间的失衡而造成氧化应激。ROS 在多种疾病(包括炎症、动脉粥样硬化、衰老和年龄相关退行性疾病)的进展中发挥重要作用。仅

供研究使用。不得用于任何动物或人类的治疗或诊断。
仅供科研使用。不可用于诊断程序。
规格
颜色绿色
最大浓度2.5 mM stabilized solution in DMSO
适用于(设备)Imaging, HCS, Cytometer
产品规格冰冻
数量5 x 50 μL
检测方法Live Cell Imaging
激发/发射485/520 nm
指示器Oxidative stress
产品线CellROX™
Unit SizeEach
内容与储存
Store at ≤–20°C. Protect from light and desiccate.

常见问题解答 (FAQ)

哪些染料可以用来检测细菌内的活性氧(ROS)?

许多对哺乳动物细胞使用的染料也可以用于细菌。例如,CellROX Deep Red试剂经证实可以用于检测B. subtilis的活性氧(见参考文献http://www-brs.ub.ruhr-uni-bochum.de/netahtml/HSS/Diss/RaatschenNadja/diss.pdf)。如果您对某一特定染料有兴趣但不知道它对您的细菌是否有效,最佳途径是通过文献检索的方式查看它是否已经过试验。如果没有,则可能需要您亲自测试。

我试着用活性氧(ROS)指示染料标记我的细胞,但没有观察到信号的明显差异。这是怎么回事?

首先,确保您同时拥有一个阴性(未处理)和一个阳性(ROS诱导)样本进行比较。100 µM甲萘醌1小时或是50 µM奈法唑酮24小时可以作为很好的阳性对照。H2O2 虽然不能很好地与CellROX染料兼容,但也可以用于阳性对照。某些如H2DCFDA的染料需要酯酶切割,所以不能在血清(血清中包含的酯酶可过早切割染料)存在的情况下进行培养。如果您的阳性对照相对于阴性对照没有明显变化,尝试着增加染料浓度和标记时间。我们的实验指南给出了启动建议。进行活细胞成像时尽可能得快。只有两种染料(CellROX Green和CellROX Deep Red)经甲醛固定处理后能保留在样品中。最后,确保您使用的滤光片和仪器设置与染料的激发和发射光谱相匹配。

I need a formaldehyde-fixable reactive oxygen species detection assay. Is H2 DCFDA fixable?

H2DCFDA and similar derivatives are not fixable. The same goes for dihydroethidium and dihydrorhodamine. However, CellROX Deep Red and CellROX Green are retained for a limited time upon fixation with formaldehyde. CellROX Green may be retained upon subsequent Triton X-100 permeabilization. Avoid the use of any acetone or alcohol-based fixatives or fixatives that include alcohol, such as formalin.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Can CellROX Green dye diluted in DMSO be subjected to freeze-thaw cycles?

CellROX Green dye diluted in a DMSO stock solution is stable for multiple freeze-thaw cycles, but it is not stable long-term in aqueous solution. Please note, every time the stock solution is opened, some of the dye can oxidize, which will increase background noise. DMSO readily absorbs moisture from the air, especially when cold, so be sure to completely thaw the stock solution to room temperature before opening and only open briefly. Water in the DMSO will gradually cause the dye to precipitate and come out of solution. Minimize the number of times you use a stock solution to several freeze-thaw cycles or make small aliquots to reduce the number of freeze-thaw cycles.

Find additional tips, troubleshooting help, and resources within our Flow Cytometry Support Center.

What is the difference between the CellROX Green Flow Cytometry Assay Kit (Cat. No. C10492) and CellROX Green Reagent, for oxidative stress detection (Cat. No. C10444)?

The main difference between the CellROX Green Flow Cytometry Assay Kit (Cat. No. C10492) and CellROX Green Reagent, for oxidative stress detection (Cat. No. C10444), is the suggested final working concentrations and application. The CellROX Green in the CellROX Green Flow Cytometry Assay Kit is specifically designed for flow cytometry analysis and is used at a lower concentration than what is required for imaging, as fluorescence-activated cell sorting (FACS) is a very sensitive detection system.

The standalone CellROX Green Reagent (Cat. No. C10444) is marketed for fluorescent microscopy and require working concentrations appropriate for imaging. This can typically be as much as 10-fold higher than the concentration recommended for flowcytometry. The standalone CellROX Green Reagent can also be used for flowcytometry; however, the working concentration will have to be optimized. For the flow cytometry quick reference, use the link below.

CellROX Flow Cytometry Assay Kit Quick Reference

Find additional tips, troubleshooting help, and resources within our Flow Cytometry Support Center.