TSQ Altis™ 三重四极杆质谱仪
TSQ Altis™ 三重四极杆质谱仪
TSQ Altis™ 三重四极杆质谱仪
TSQ Altis™ 三重四极杆质谱仪
TSQ Altis™ 三重四极杆质谱仪
TSQ Altis™ 三重四极杆质谱仪
Thermo Scientific™

TSQ Altis™ 三重四极杆质谱仪

Thermo Scientific TSQ Altis 质谱仪为不同专业级水平的用户提供了极致的灵敏度、耐用性和易用性。

Have Questions?
货号类型
TSQ02-10002三重四极杆 LC-MS
货号 TSQ02-10002
价格(CNY)
-
申请报价
类型:
三重四极杆 LC-MS

使用 Thermo Scientific™ TSQ Altis™ 三重四极杆质谱仪,应对目标物定量工作流程中极严格的分析挑战。应用改进的主动离子管控 (AIM™) 技术、分段四极杆、增强型双模电子倍增器和高通量离子传输管,TSQ Altis MS 可在不牺牲耐用性的情况下为复杂基质中所有分子类型的分析实现极高的实验灵敏度。

灵敏度和耐用性:同时兼顾

TSQ Altis 三重四极杆质谱仪及领先行业的定量软件、UHPLC 系统和卓越的样品制备试剂盒,可帮助研究人员解决目标物定量分析的稳健、可靠和灵敏关键性挑战。TSQ Altis 质谱仪的主要优点包括:

  • 满足从简单到复杂基质中所有分子类型的分析的极高灵敏度。
  • 出色的仪器耐用性确保在提高数据可靠性的同时不损失仪器正常运行时间。
  • 超快的选择反应监测 (SRM) 能够在更短时间内增加分子定量的数量。
  • 与专业应用软件紧密集成,提高了所有应用领域的生产率。
  • 简单易用,帮助不同专业级水平的用户获得高质量的结果,并提高可靠性。
规格
适用于(应用)制药、环境、食品安全、临床研究和法医毒理学
质量范围5 至 2000 m/z
类型三重四极杆 LC-MS
Unit SizeEach

常见问题解答 (FAQ)

How do I clean/store my Triple Quadrupole mass spectrometry instruments after analysis?

For short periods (less than 24 hr) the system can just be put into standby. However, it is good practice to flush the system with 50:50 solvent/water (where the solvent is either methanol or acetonitrile) to remove buffers or additives and stop microbial growth.

For longer periods, flush the LC system with 50:50 solvent/water. Then flush with 100% solvent. Put the system into standby.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

How do I perform mass calibration on Triple Quadrupole mass spectrometry instruments and how often should I do it?

The mass calibration should ideally be performed every 3 months and definitely performed at least every 6 months. Refer to the Instrument Manual (https://tools.thermofisher.com/content/sfs/manuals/TSQ-Series-Hardware.pdf) for detailed instructions on how to perform mass calibration.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

How should I clean the Ion Transfer Tube on Triple Quadrupole mass spectrometry instruments?

The Ion Transfer Tube should be removed and sonicated in a 50:50 solution of methanol/water that contains 20% formic acid for 30 min. Rinse thoroughly with water. Then sonicate in methanol for 15 min. Dry with nitrogen gas.

The same procedure can be applied to the Ion Sweep Cone.

Refer to the Instrument Manual (https://tools.thermofisher.com/content/sfs/manuals/TSQ-Series-Hardware.pdf) for more detailed instructions.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

How should I adjust my ion source position on Triple Quadrupole mass spectrometry instruments?

Perform loop injections of your analyte using isocractic elution through a short column at the flow rate and approximate mobile phase composition. Use a concentration where the signal to noise is approximately 10:1. Record the raw data file and integrate the peaks, comparing peak areas at different source positions (i.e., left and right, up and down, fore and aft). Ensure that the background noise is not increasing more than the peak area.

Note: The needle position on the Thermo Fisher Scientific TSQ Altis MS, TSQ Quantis MS, and TSQ Fortis MS instruments is set and should not be adjusted.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.

Do I need to warm/equilibrate Triple Quadrupole mass spectrometry instruments prior to starting a session of analysis?

It is advisable to turn both the LC system and the MS system on for at least 30 min prior to analysis. This time can usually be spent testing one or more solvents or matrix blanks.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.