Hamburger Menu Button
Thermo Fisher Scientific Logo
登录
没有账号?建立账号 注册
  • 产品
    • 抗体
    • 引物合成
    • GeneArt Gene Synthesis Instant Designer
    • TaqMan Assay and Array Search
    • PCR 设备和耗材
    • 色谱柱和纯化柱
    • 实验室离心机
    • 分子生物学试剂和试剂盒
    • 实验室塑料耗材及用品
    • 查看所有产品分类
  • 应用和技术
    • 色谱
    • 细胞转染和培养
    • 实时荧光定量PCR
    • 质谱
    • 实验室塑料耗材及用品
    • 电子显微镜
    • 蛋白质生物学
    • PCR
    • RNAi
    • 环境
    • 查看所有应用和技术
  • 服务
    • 定制服务
    • 企业级实验室信息化服务
    • 企业服务
    • 金融&租赁服务
    • 仪器服务
    • OEM和商业供应
    • 培训服务
    • 360° CDMO 和 CRO 服务
    • CDMO 服务
    • 临床试验 CRO 服务
    • 查看所有帮助和支持
  • 帮助和支持
    • 学习中心
    • 联系我们
    • 更改国家或地区
    • 查看所有帮助和支持
  • 热门产品
    • TaqMan Real-Time PCR Assays
      TaqMan 实时荧光定量 PCR 试剂盒
    • Antibodies
      抗体
    • Oligos, Primers & Probes
      寡核苷酸、引物、探针
    • GeneArt Gene Synthesis
      GeneArt 基因合成
    • Cell Culture Plastics
      细胞培养耗材
  • 联系我们
  • 货号直购
  • 订单查询
  • 查找文件&证书
Thermo Fisher Scientific Logo

Search

搜索全部或下列指定分类
Search button
          • 联系我们
          • 货号直购
          • 登录
            登录
            没有账号?建立账号 注册
            • 我的账号
            • 订单
            • 账单及发票查询
            • 定制产品及项目

          The EU-China-Safe Project: The Assessment of a Dioxin Analytical Workflow in Food and Feed

          • Overview
          • Presenters

          The EU-China-Safe project is a jointly funded EU/Chinese project that aims to deliver a shared vision for food safety and authenticity based on “mutual recognition” in food standards, testing and certification. Partners in China and Europe identified that validating GC–MS/MS methods for dioxins analysis is as an economic option to build value for money testing capacity. As part of the EU-China-Safe project, Fera Science Limited (Fera) performed analysis of PCDDs, PCDFs, and dl-PCBs in food using a preconfigured Thermo Scientific TSQ 9000 triple quadrupole GC–MS/MS system equipped with the new Advanced Electron Ionization (AEI) source. An important aspect of the collaboration was the development of an EU-China Joint Laboratory Network, which conducted a study using shared data systems to enable cooperative development of a method to demonstrate equivalency with traditional HRMS. Study results obtained from proficiency test (PT) and quality control (QC) samples were within the expected concentration ranges. These findings demonstrate that the limit of quantification (LOQ) complied to one-fifth maximum levels, and that the analytical method demonstrated the sensitivity, selectivity, and robustness required to satisfy current EU regulations 644/2017 and 771/2017.

          In this webcast, we will provide an overview of how methods are being developed by the EU-China-Safe project and focus on the particular benefits of the TSQ 9000 and AEI technology for dioxin analysis.

          Key Learning Objectives:

          • Overview of the EU-China-Safe project and how methods are being developed within the project
          • Discover a fully validated dioxin analyzer with pre-loaded acquisition, calculation and reporting templates to simplify user training and increase productivity soon after installation
          • Learn how this analytical solution is easily implemented into laboratories and able to meet EU performance criteria
          • Understand how GC–MS/MS with enhanced sensitivity enables users to lower sample weight to reduce both the cost of sample preparation and system maintenance

          Who Should Attend:

        • Analysts and laboratory managers working in reference and contract testing laboratories
        • Scientists and chemists at the government agencies, universities and food manufacturers
        • Analysts performing dioxin analysis
        • Sean Panton, Analytical Chemist, Food Safety and Quality, Fera Science Limited

          Sean Panton, Analytical Chemist, Food Safety and Quality, Fera Science Limited

          Sean is an analytical chemist working in the Organic Environmental Contaminants team at Fera Science Limited in York, UK. Sean has over 25 years of experience in food analysis. Sean started out in the pesticides team at Fera, developing GC- and HPLC-based methods and researching the fate of pesticides during food processing. For the last 15 years, he has been involved in analysis of polyaromatic hydrocarbons (PAHs), PCBs, dioxins, brominated flame retardants (BFRs) in food and environmental samples using GC-MS, GC-MS/MS and GC-HRMS platforms.

          Aaron Lamb, Senior Marketing Application Specialist, Thermo Fisher Scientific

          Aaron Lamb, Senior Marketing Application Specialist, Thermo Fisher Scientific

          Aaron is a senior mass spectrometry applications specialist working in the Chromatography and Mass Spectrometry Division at Thermo Fisher Scientific in Runcorn, UK. Aaron is an experienced analytical chemist responsible for application method development using quadrupole- and Orbitrap-based GC-MS systems for food and environmental markets. Aaron has also worked in industry as an R&D and Pharma team leader at Intertek, using a multitude of analytical techniques, including ion chromatography, GC-MS and LC-MS in health care and pharmaceutical analyses.

          Overview

          The EU-China-Safe project is a jointly funded EU/Chinese project that aims to deliver a shared vision for food safety and authenticity based on “mutual recognition” in food standards, testing and certification. Partners in China and Europe identified that validating GC–MS/MS methods for dioxins analysis is as an economic option to build value for money testing capacity. As part of the EU-China-Safe project, Fera Science Limited (Fera) performed analysis of PCDDs, PCDFs, and dl-PCBs in food using a preconfigured Thermo Scientific TSQ 9000 triple quadrupole GC–MS/MS system equipped with the new Advanced Electron Ionization (AEI) source. An important aspect of the collaboration was the development of an EU-China Joint Laboratory Network, which conducted a study using shared data systems to enable cooperative development of a method to demonstrate equivalency with traditional HRMS. Study results obtained from proficiency test (PT) and quality control (QC) samples were within the expected concentration ranges. These findings demonstrate that the limit of quantification (LOQ) complied to one-fifth maximum levels, and that the analytical method demonstrated the sensitivity, selectivity, and robustness required to satisfy current EU regulations 644/2017 and 771/2017.

          In this webcast, we will provide an overview of how methods are being developed by the EU-China-Safe project and focus on the particular benefits of the TSQ 9000 and AEI technology for dioxin analysis.

          Key Learning Objectives:

          • Overview of the EU-China-Safe project and how methods are being developed within the project
          • Discover a fully validated dioxin analyzer with pre-loaded acquisition, calculation and reporting templates to simplify user training and increase productivity soon after installation
          • Learn how this analytical solution is easily implemented into laboratories and able to meet EU performance criteria
          • Understand how GC–MS/MS with enhanced sensitivity enables users to lower sample weight to reduce both the cost of sample preparation and system maintenance

          Who Should Attend:

        • Analysts and laboratory managers working in reference and contract testing laboratories
        • Scientists and chemists at the government agencies, universities and food manufacturers
        • Analysts performing dioxin analysis
        • Presenters
          Sean Panton, Analytical Chemist, Food Safety and Quality, Fera Science Limited

          Sean Panton, Analytical Chemist, Food Safety and Quality, Fera Science Limited

          Sean is an analytical chemist working in the Organic Environmental Contaminants team at Fera Science Limited in York, UK. Sean has over 25 years of experience in food analysis. Sean started out in the pesticides team at Fera, developing GC- and HPLC-based methods and researching the fate of pesticides during food processing. For the last 15 years, he has been involved in analysis of polyaromatic hydrocarbons (PAHs), PCBs, dioxins, brominated flame retardants (BFRs) in food and environmental samples using GC-MS, GC-MS/MS and GC-HRMS platforms.

          Aaron Lamb, Senior Marketing Application Specialist, Thermo Fisher Scientific

          Aaron Lamb, Senior Marketing Application Specialist, Thermo Fisher Scientific

          Aaron is a senior mass spectrometry applications specialist working in the Chromatography and Mass Spectrometry Division at Thermo Fisher Scientific in Runcorn, UK. Aaron is an experienced analytical chemist responsible for application method development using quadrupole- and Orbitrap-based GC-MS systems for food and environmental markets. Aaron has also worked in industry as an R&D and Pharma team leader at Intertek, using a multitude of analytical techniques, including ion chromatography, GC-MS and LC-MS in health care and pharmaceutical analyses.

          Register to view the free
          on-demand webinar

          * Required field

          *
          *
          *
          *
          *
          *
           
          *
          *
          *
          *

           I would like to speak with an expert to learn how Thermo Fisher Scientific products can help in my laboratory
           Please confirm you would like to receive marketing and promotional email messages about Thermo Fisher Scientific products and services.
           
           
          订购 Plus Icon Minus Icon
          • 订单状态查询
          • 订单支持
          • 货号直购
          • 现货供应中心
          • 电子采购
          支持 Plus Icon Minus Icon
          • 帮助&支持
          • 联系我们 - 400 820 8982
          • 技术支持中心
          • 查找文件&证书
          • 报告网站问题
          资源 Plus Icon Minus Icon
          • 学习中心
          • 促销
          • 活动&研讨会
          • 社交媒体
          关于赛默飞 Plus Icon Minus Icon
          • 关于我们
          • 招聘 招聘
          • 投资者关系 投资者关系
          • 新闻 新闻
          • 社会责任 社会责任
          • 商标
          • 政策和通知
          品牌 Plus Icon Minus Icon
          • Thermo Scientific
          • Applied Biosystems
          • Invitrogen
          • Gibco
          • Ion Torrent
          • Patheon
          • PPD
          • 服务条款
          • 隐私政策
          • 定价和运输保险政策
          © 2006-2025 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified.
          China flag icon
          China
          本网站销售的所有产品均不得用于人类或动物之临床诊断或治疗,仅可用于工业或者科研等非医疗目的。
             电子营业执照 | 经营证照公示 | ICP备案号:沪ICP备11003924号 | 沪公网安备 31011502006935号