eBioscience™ 1-step 固定/裂解溶液 (10X)
Product Image
Invitrogen™

eBioscience™ 1-step 固定/裂解溶液 (10X)

使用荧光染料抗体对外周血细胞进行染色之后,可使用 eBioscience 1-step 固定/裂解溶液裂解红血细胞。该溶液经过专门配方设计,可裂解无核红细胞,同时保持固定和标记的白细胞群。因此,可使用合适的标记物对全血样品进行染色、RBC 裂解和固定、清洗,然后使用流式细胞分析进行分析。使用该溶液时,无需通过梯度离心了解更多信息
Have Questions?
更改视图buttonViewtableView
货号数量
00-5333-5450 mL
00-5333-57200 mL
货号 00-5333-54
价格(CNY)
1,014.00
飞享价
Ends: 31-Dec-2025
1,346.00
共减 332.00 (25%)
Each
添加至购物车
数量:
50 mL
价格(CNY)
1,014.00
飞享价
Ends: 31-Dec-2025
1,346.00
共减 332.00 (25%)
Each
添加至购物车
使用荧光染料抗体对外周血细胞进行染色之后,可使用 eBioscience 1-step 固定/裂解溶液裂解红血细胞。该溶液经过专门配方设计,可裂解无核红细胞,同时保持固定和标记的白细胞群。因此,可使用合适的标记物对全血样品进行染色、RBC 裂解和固定、清洗,然后使用流式细胞分析进行分析。使用该溶液时,无需通过梯度离心(例如 Ficoll-Paque 密度梯度分离)分离单核细胞。eBioscience 1-step 固定/裂解溶液兼容与有机染料和串联染料结合的抗体。

已报告应用
流式细胞术分析

仅供科研使用。不可用于诊断程序。
规格
产品线eBioscience™
数量50 mL
类型1 步固定/裂解液
Unit SizeEach

常见问题解答 (FAQ)

Can I use homemade fixation buffers (or other commercially available fixatives) on my cells after staining with eVolve-conjugated antibodies?

No. For optimal results, we recommend that you use the IC Fixation Buffer (Cat. No. 00-8222-49) or 1-step Fix/Lyse Solution (Cat. No. 00-5333-54 or 00-5333-57). Impurities in fixation buffers can severely affect fluorochrome brightness.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Can I use homemade fixation buffers (or other commercially available fixative) on my cells followed by flow cytometric analysis?

No. We do not recommend the use of other fixatives. We validate our studies using eBioscience's IC Fixation Buffer (Cat. Nos. 00-8222-49, 00-8222-52) and 1-step Fix/Lyse Solution (Cat. Nos. 00-5333-54, 00-5333-57). Other recipes or manufacturer's products may give inferior results.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I can not run my samples for flow cytometric analysis immediately. What do I do to preserve the best intracellular staining?

For optimal results, we recommend that you analyze stained cells immediately.

However, if you do need to store your samples that were stained with antibodies conjugated to organic fluorochromes, we recommend you complete your staining protocol and fix your samples with IC Fixation Buffer (Cat. Nos. 00-8222-49, 00-8222-52) (100 µL sample with 100 µL IC Fixation Buffer) or 1-step Fix/Lyse Solution (Cat. Nos. 00-5333-54, 00-5333-57). Cells can be stored in these buffers for up to 3 days in the dark at 4 degrees C.

We have observed minimal impact on brightness or FRET efficiency/compensation when using the IC Fixation (Cat. Nos. 00-8222-49, 00-8222-52) or 1-step Fix/Lyse Solution (Cat. Nos. 00-5333-54, 00-5333-57). Differences in fixation buffer quality can affect fluorochrome brightness or FRET efficiency. Fixation of tandem dyes, such as APC-eFluor 780 and PE-Cy7, does not increase the amount of compensation required from the APC or PE detector, respectively. Some generalizations regarding fluorophore performance after fixation can be made, but clone specific performance should be determined empirically.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Can samples stained with antibodies conjugates to tandem dyes (i.e., APC-eFluor 780, PE-Cy7, etc.) be fixed and stored?

Yes, samples that are stained with tandem dye conjugated antibodies can be stored in IC Fixation Buffer (Cat. No. 00-8222-49, 00-8222-52) (100 µL sample with 100 µL IC Fixation Buffer) or 1-step Fix/Lyse Solution (Cat. No. 00-5333-54, 00-5333-57) for up to 3 days in the dark at 4 degrees C with minimal impact on brightness and FRET efficiency/compensation. Some generalizations regarding fluorophore performance after fixation can be made, but clone specific performance should be determined empirically.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.