UltraPure™ TBE 缓冲液,10X
Invitrogen17万+抗体限时买二赠一,靶点广,灵活用!
UltraPure™ TBE 缓冲液,10X
Invitrogen™

UltraPure™ TBE 缓冲液,10X

UltraPure™ 10X TBE 缓冲液是一种无菌过滤的 1 M Tris、0.9 M 硼酸和了解更多信息
Have Questions?
更改视图buttonViewtableView
货号数量
1558102810 L
155810441 L
货号 15581028
价格(CNY)
3,153.00
飞享价
Ends: 31-Dec-2025
6,247.00
共减 3,094.00 (50%)
Each
添加至购物车
数量:
10 L
请求批量或定制报价
价格(CNY)
3,153.00
飞享价
Ends: 31-Dec-2025
6,247.00
共减 3,094.00 (50%)
Each
添加至购物车
UltraPure™ 10X TBE 缓冲液是一种无菌过滤的 1 M Tris、0.9 M 硼酸和 0.01 M EDTA 溶液,以制备用于聚丙烯酰胺和琼脂糖凝胶电泳的 1X 缓冲液。UltraPure™ 10X TBE 缓冲液以 1 L 塑料瓶或 10 L Cubitainer™ 纸箱的形式提供。

性能和质量检测
未检测到 DNase、RNase 或蛋白酶活性。
仅供科研使用。不可用于诊断程序。
规格
缓冲液运行缓冲液
最大浓度10 X
适用于(应用)核酸凝胶电泳、印迹
凝胶兼容性聚丙烯酰胺凝胶、琼脂糖凝胶
产品线UltraPure™
产品类型TBE 缓冲液
数量10 L
运输条件室温
产品规格瓶装
Unit SizeEach
内容与储存
在室温下储存。

常见问题解答 (FAQ)

Can I autoclave agarose to prepare agarose gels?

No. Autoclaving at temperatures that are too high or pressures that are too high can hydrolyze the agarose polymer and weaken it.

Do you have any tips for preparing high-percentage (3% to 4%) agarose gels?

Add the powder to cold buffer while stirring. Let the agarose rehydrate for 1 to 2 hr and then heat slowly until agarose is completely dissolved. Using a microwave at low power settings is acceptable.

What can I do to prevent static on agarose bottles?

One recommendation: get a supply of fabric softener sheets and wipe the bottle with a sheet before opening it.

How can I avoid the build-up of the precipitous film sometimes seen in 10X TBE?

The precipitation of concentrated TBE stocks may be due to nucleation of salt crystals by dust particles or other insoluble materials. Therefore, filtering the solution through a 0.2 µm cellulose acetate or cellulose nitrate filter after preparation helps avoid this precipitate. [Mayeda A, Krainer A (1991) BioTechniques 10.2, 1820]

How can generation of replication competent adenoviruses be avoided when using your pSilencer adeno 1.0-CMV System?

Although there is only a very small chance of creating replication competent virus, steps should still be taken to avoid added risk. The virus is expanded in two rounds of amplification, and all secondary expansions should be performed from an initial expansion stock. Secondary amplifications in HEK293 cells should not be performed from the stock of another secondary expansion, as this could increase the chance of making replication competent virus. See the product manual for more detail and guidelines for screening.

Find additional tips, troubleshooting help, and resources within our RNAi Support Center.