采用聚苯乙烯黑色或白色上部结构及薄层聚苯乙烯板底的 Thermo Scientific™ Nunc™ MicroWell™ 盖玻片底 96 孔光学底透板可实现细胞培养和显微镜检应用中极佳的荧光和化学发光检测性能。

特点:

  • 改善背景、自动荧光和串扰
  • 黑色微孔板用于荧光测量,具有较小的背散射光与背景荧光
  • 白色微孔板用于化学发光测量,具有较大的反射和较小的自发光
  • 细胞培养处理表面是用于细胞检测的理想之选
  • CC2 表面改性与多聚-D-赖氨酸非常相似,能很好地附着对培养表面较为挑剔的细胞,使细胞良好地生长
  • 可提供定制条形码服务
规格
认证/合规Nunc 生产的所有微孔板都满足美国国家标准学会 (ANSI) 推荐的标准 (ANSI/SBS 1-2004)。
带盖
每箱数量30
每架数量6
包装6 包,30 箱
产品类型塑料、无涂层、非无菌孔板
数量Case of 30
数组8 x 12
颜色黑色, 透明底部
材质聚苯乙烯
孔数量96
产品线Nunc™
无菌无菌
表面处理细胞培养
孔形
Unit SizeCase of 30

常见问题解答 (FAQ)

What is the difference between the Nunclon Delta surface and a tissue culture (TC) surface from a competitor?

Our Nunclon Delta surface for adherent cells is a standard tissue culture (TC) surface modification that makes the polystyrene surface more hydrophilic. This facilitates maximum adhesion for a broad range of cell types.

The Nunclon Delta surface is Thermo Scientific Nunclon Delta-certified, which is a Thermo Fisher proprietary certification that has a quality standard to help ensure consistency. Every lot of Thermo Scientific Nunclon Delta-certified cell cultureware is tested with Gibco media for:
- Less than 10% growth variation in L929, Hel299 and primary chick embryo cells
- Less than 15% variation colony formation of V79-4 cells

More information and all applicable products can be found in the "Product selection guide for every step of your cell culture workflow" brochure .

How does cell culturing on Nunc 384-Well Microplates that have a cell culture-treated surface compare with 96-Well Microplates that have a cell culture-treated surface?

The cell culture-treated surfaces are very similar but the wells of the Nunc 384-Well Microplates are smaller than the wells of the Nunc 96-Well Microplate.
Culture recommendations for the Nunc 384-Well Microplates are:
- 15 - 50 µL media per well
- 0.5 - 2.0 x 10^4 cells per well

Should I use an opaque black/white immuno plate, or an "optical-bottom" design?

Opaque plates can only be used on “top reader” instruments, which detect (or, in fluorescence mode, excite and detect) from above the plate. Readers that detect from underneath the plate (or imaging systems) use optical-bottom plates, which have a black or white upper well structure and a transparent (polystyrene film or optical coverglass) bottom.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.