Multidrop™ Combi 附件
Multidrop™ Combi 附件
Actual product may vary
Thermo Scientific™

Multidrop™ Combi 附件

Combi 附件可保证出色的分液结果和稳定性能。
Have Questions?
更改视图buttonViewtableView
货号描述产品类型数量
24073290小管塑料吸头分液盒管分液盒1 Ea.
N12928小型 8 管卡盒管试剂过滤器1 Ea.
N12929小型长管卡盒管试剂过滤器1 Ea.
2805980试管架组件1 Ea.
15280030高版本灌注容器1 Ea.
N13132小型长管卡盒,5 包管试剂过滤器5 Pk.
N13131小型 8 管卡盒,5 包管试剂过滤器5 Pk.
24073291小管塑料头分液盒,每包5个管分液盒5 Pk.
24073293长小管塑料吸头分液盒(管长 200 cm)管分液盒1 Ea.
24073295长小管金属吸头分液盒管分液盒1 Ea.
24073296小管金属吸头分液盒,每包 5 个管分液盒5 Pk.
24073298长小管金属吸头分液盒(管长 200 cm)管分液盒1 Ea.
货号 24073290
价格(CNY)
-
描述:
小管塑料吸头分液盒
产品类型:
管分液盒
数量:
1 Ea.

Thermo Scientific™ Multidrop™ Combi 附件可保证出色的分液结果和稳定性能。

Thermo Scientific™ Multidrop™ Combi 附件可保证出色的分液结果和稳定性能。

有限质保期:根据我们的《销售条款和条件》中确定的所有保修要求和除外条款,此产品从产品运输之日起享受九十(90)天保修。对内部研究使用限制的免责声明:购买方仅可将产品用于内部研究的任何限制,不适用于与此声明相关网页页面上的产品。
规格
可高温高压灭菌可经历 10 次 121°C、1 bar、20 min 的高压灭菌
描述小管塑料吸头分液盒
直径(公制)提示:0.22 mm;管:0.4 mm
适用于(设备)Multidrop Combi, Multidrop Micro
数量1 Ea.
死区体积(公制)<1 mL
材质聚丙烯吸头, 硅胶管
产品类型管分液盒
容积(公制)0.5 至 50 μL
Unit SizeEach

常见问题解答 (FAQ)

What are the tubing lengths of the regular length and extended length cassettes for the Multidrop Combi Reagent Dispensers?

Regular length tubing (small and standard) cassette length is 40 cm long.

Extended length tubing (small and standard) cassette length is 200 cm long.
Note: You can cut the extended length tubing to the desired length but we recommend checking the calibration on the cassette, once modified, to ensure it is providing accurate results.

Can I repair Multidrop Combi small tubing cassettes or replace the tubing in them, instead of purchasing a new cassette?

No, you cannot repair or replace the tubing in the Multidrop Combi small tubing cassettes. If you attempt to do so, the cassette may not function properly. The small tubing cassettes incorporate either plastic tips or metal tips. While metal tip cassettes will last longer than plastic tip cassettes, once the tubing in a cassette wears or reaches its end of life (EOL), the entire cassette will need to be replaced with a brand-new cassette.

When should I use the Multidrop Combi tube reagent filter accessories for Multidrop Combi small tube cassettes?

We recommend using the filters to help prevent cassette tips from getting clogged during use. Dust, particles, and fibers commonly found in the lab can cause clogging in the Thermo Scientific Multidrop Combi cassettes, preventing reliable dispensing. Keeping particles from entering the tubing helps reduce the likelihood of a clogged tip in small tubing dispensing cassettes. The filter also acts as a weight to hold the tubing in the source vessel. To use the filter, simply remove the tubing weight from the end of the small cassette tubing and replace it with a filter.

Can the SMART cassettes with RFID tags be used with the standard Multidrop Combi without SMART option or vice versa?

Yes, the cassettes are interchangeable, however, the calibration data cannot be viewed and the information about the cassette is not updated. Also standard cassettes can be used with the Multidrop Combi with SMART option.

What should I do if the liquid foams during dispensing with the Multidrop Combi?

Some liquids foam more easily than others. One option is to reduce the pump rotor speed. There are three dispensing speeds available: High, Med (medium), and Low.