PrimeFlow™ 96 孔板 10 包
Product Image
Invitrogen™

PrimeFlow™ 96 孔板 10 包

这些 PrimeFlow™96 孔板是 V 形底的聚苯乙烯板,经验证可与 PrimeFlow™ RNA 检测联用。已报告应用RNA 流式细胞分析了解更多信息
Have Questions?
货号数量
44-17005-4610 Packets
货号 44-17005-46
价格(CNY)
1,202.00
10 Packets
添加至购物车
数量:
10 Packets
价格(CNY)
1,202.00
10 Packets
添加至购物车
这些 PrimeFlow™96 孔板是 V 形底的聚苯乙烯板,经验证可与 PrimeFlow™ RNA 检测联用。

已报告应用
RNA 流式细胞分析

仅供科研使用。不可用于诊断程序。
规格
检测方法比色法
包装10 个/包装
板封闭
产品类型塑料、无涂层、非无菌孔板
数量10 Packets
颜色透明
材质聚苯乙烯
孔数量96
产品线PrimeFlow
孔形V
Unit Size10 Packets

常见问题解答 (FAQ)

Can the FlowRNA Assay be adapted to a 96-well protocol? Do you have a protocol for this?

Yes. We have a validated protocol for Flow RNA assay in 96-wells. Please see Appendix 7 of Cat. No. 88-18005 for the protocol.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

When running the QuantiGene FlowRNA (methanol based) assay, which fluorochromes are recommended for antibody staining?

We recommend the use of fluorochromes that are known to be methanol resistant. Avoid protein-based fluorochromes such as APC, PE, and PerCP and their respective tandems. This question is not appropriate for PrimeFlow RNA Assay.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

For the PrimeFlow RNA Assay, how would you recommend I set compensation?

We recommend using the PrimeFlow Compensation Kit included in the PrimeFlow RNA Assay (Cat. No. 88-18005-204, 88-18005-210) to set compensation for each RNA channel. Refer to Appendix 3 of the PrimeFlow RNA Assay User Manual for detailed instructions for use. The UltraComp eBeads microspheres included in the compensation kit may also be used for any experimental antibodies being used. Antibodies with the same fluorochromes as the RNA probes should not be used to set compensation for RNA probes, as the compensation values will be different.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I have a 37 degrees C tissue culture incubator in the lab. Can I use this incubator for the hybridization steps in the PrimeFlow RNA Assay protocol?

The hybridization temperature is a critical parameter of this protocol necessary to obtain positive results. The incubator to be used must be validated before use with the ViewRNA Temperature Validation Kit (Cat. No. QV0523), following the protocol in the FlowRNA user manual. Temperatures deviated outside of this range will lead to less-than-optimal hybridization.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What type of 96-well plate is compatible with the PrimeFlow RNA protocol?

We recommend polystyrene uncoated v-bottom 96-well plates with a lid (Cat. No. 44-17005-46). The u-bottom plate is also acceptable, but flat bottom plates are not recommended.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.