Megaplex™ 引物池 Human Pools Set v3.0
Product Image
Applied Biosystems™

Megaplex™ 引物池 Human Pools Set v3.0

Green features
Megaplex™ 引物池 Human Pools Set v3.0 在单一产品编号下可用,其中含有 Megaplex™ RT 引物了解更多信息
Have Questions?
货号数量
444475050 reactions
货号 4444750
价格(CNY)
17,518.00
Each
添加至购物车
数量:
50 reactions
价格(CNY)
17,518.00
Each
添加至购物车
Megaplex™ 引物池 Human Pools Set v3.0 在单一产品编号下可用,其中含有 Megaplex™ RT 引物 Human Pool A v2.1、Megaplex™ RT 引物 Human Pool B v3.0、Megaplex™ PreAmp 引物 Human Pool A v2.1 和 Megaplex™ PreAmp 引物 Human Pool B v3.0。Megaplex™ 引物池 Human Pools Set v3.0 含 RT 引物(可用于 754 种独特的 microRNA)和 4 份对照品。Megaplex™ PreAmp 引物适合检测灵敏度非常重要的实验,可大幅提升检测低表达水平 microRNA 的能力,以尽可能低的样品量(例如低至 1 ng 总 RNA 的起始量)生成全面表达谱。Megaplex™ 引物池 Human Pools Set v3.0 预期与 TaqMan® Array Human MicroRNA Card Set v3.0 配合使用,但是其也可用于使用单独的 TaqMan® MicroRNA 检测试剂制备实时分析所用的 cDNA。
仅供科研使用。不可用于诊断程序。
规格
环保功能绿色可持续包装
反应次数50 次反应
引物RT 引物、PreAmp 引物
产品线Megaplex™
产品类型引物池
数量50 reactions
种属
足够用于50 次反应
适用于(应用)miRNA 分析
高 GC PCR 扩增效果
PCR 方法qPCR
Unit SizeEach
内容与储存
在-20°C条件下储存

常见问题解答 (FAQ)

Can Ct's greater than a cut-off be considered valid results?

Yes they can. However, it is important to recognize the true linearity and detection limits of your assay: Ct values above the cut-off can indicate non-specific amplification, unless your NTC is a true- no-target control, and you have run a statistically significant number of replicates. Any results with Ct above the recommended cut-off need to be validated with individual assays on plates.

What is a good Ct cut-off for the TaqMan MicroRNA Array Cards and TaqMan Advanced miRNA Array Cards? In other words, beyond what Ct should I not trust the data?

The typical Ct cut-off on TaqMan Array Cards is 32, which is equivalent to Ct 35 on a plate (10 µl reaction). Previous studies show that if you use pre-amplification, a Ct cut-off of 29 or 30 can be used to reduce numbers of false positives (see Technical Note Optimized protocols for human or rodent microRNA profiling with precious samples). To ensure that you have selected a correct cut-off, you should run replicates of the same sample and use Ct cut-off before you see an increase in the Standard Deviation.

Why are the Ct values for my endogenous controls are highly variable across the sample set?

Highly variable values for endogenous controls is most likely due to biological variation. Use an alternative endogenous control such as a non-variable miRNA.

Why is the Ct value for the No Template Control (NTC) <35 for some assays?

Please review the following possible causes and solutions:
- There are non-specific interactions between primers. For NTC information on a specific assay, refer to the Megaplex Assay Performance File.
- The cDNA template is contaminated. Please follow established PCR good laboratory practices.
- The preamplification product was not diluted properly before real-time PCR. Follow the recommendations in the protocol. Please see "Dilute the preamplification reaction" on page 18.

Why did I not detect any miRNA?

It is possible that the threshold is set too high to detect miRNA in samples with low expression. Identify an appropriate NOAMP flag threshold if the relative threshold algorithm (Crt) is used. Alternatively, identify an appropriate threshold if Ct is used.