TaqMan™ 阵列啮齿动物 MicroRNA B 卡 v3.0
Product Image
Applied Biosystems™

TaqMan™ 阵列啮齿动物 MicroRNA B 卡 v3.0

TaqMan™ 阵列啮齿动物 MicroRNA B 卡 v3.0 包含 384 份 TaqMan™了解更多信息
Have Questions?
货号 4444899
价格(CNY)
23,911.00
Each
添加至购物车
价格(CNY)
23,911.00
Each
添加至购物车
TaqMan™ 阵列啮齿动物 MicroRNA B 卡 v3.0 包含 384 份 TaqMan™ MicroRNA 检测试剂,能够在短短 5 小时内分别对 306(小鼠)和 135(大鼠)份独特 microRNA 进行准确定量测定。就每一物种而言,包含三种 TaqMan MicroRNA 检测内源参照,可辅助数据标准化,还包括一种与啮齿动物无关的 TaqMan MicroRNA 检测作为阴性对照。所含检测的详细信息见目标列表文件。若运行该阵列,需要购买 Megaplex™ RT 引物(啮齿动物引物池 B v3.0)。当对实验灵敏度要求较高和/或样品有限时,可使用 Megaplex™ PreAmp 引物(啮齿动物引物池 B v3.0)进行额外的预扩增步骤。

TaqMan阵列 MicroRNA 卡将 TaqMan™ MicroRNA 检测的所有优势集中在一张方便的预配置微流控卡中,极大限度地减少了实验变异性和同时运行 384 个 TaqMan™ MicroRNA 检测所需的工作量。

Megaplex™ RT 引物是高度多重 RT 引物,经专门设计可在实时分析之前将多达 381 个 miRNA 转换为 cDNA,也是运行 TaqMan™ 阵列 MicroRNA 卡所需的引物。当对灵敏度要求较高和/或所用样品有限时,在实时分析前可使用 Megaplex™ PreAmp 引物进行可选预扩增步骤。TaqMan™ 阵列 MicroRNA 卡和 Megaplex™ 引物池可在短短 5 小时内创建与 miRBase v21 一致的全面表达谱,从而提供理想的 miRNA 谱分析解决方案。主要产品特点:

高度特异性—仅定量具有生物活性的成熟 miRNA

高度简化的工作流程减少了每个样品的 RT(逆转录)反应次数
简化样品处理并提高样品处理量
覆盖人、小鼠和大鼠物种
理想的 miRNA 表达谱分析解决方案

简化样品处理并提高样品处理量
在使用 Megaplex™ RT 引物逆转录 miRNA 靶标以及使用 Megaplex™ PreAmp 引物进行可选的预扩增后,将 TaqMan™ 通用型 PCR 预混液 II 与各反应物简单混合,并移取至 TaqMan™ 阵列卡的每个上样端口中,从而简化样品处理并提高样品处理量。

提供全范围的 Sanger miRBase
Megaplex™ RT 池和 PreAmp 引物可用于人和啮齿动物物种,包括一系列引物池中预先选择和匹配的内容物与 TaqMan™ 阵列卡。该内容物来源于 miRBase v14 和 v15(分别为人和啮齿动物物种),提供接近全范围的 Sanger 与较新的 TaqMan™ MicroRNA 检测试剂。
For Research Use Only. Not for use in diagnostic procedures.
规格
适用于(设备)AB 7900 HT 384 孔系统
形式干燥
包括384 孔阵列,信息 CD
标签或染料FAM
产品线TaqMan™
数量4 pack
反应速度标准
研究类别基因调控,表观遗传学
类型阵列啮齿动物 MicroRNA B 卡
产品规格384孔微流控卡
种属小鼠、大鼠
Unit SizeEach

常见问题解答 (FAQ)

Why does the negative control well show amplification when doing microRNA analysis using Megaplex Primer Pools and TaqMan Array Cards?

Most likely the reagents or the cDNA template are contaminated. Please follow established PCR laboratory best practices.

Why do I have poor reproducibility across technical replicates when doing microRNA analysis using Megaplex Primer Pools and TaqMan Array Cards?

Most likely the reagents were not adequately mixed. Ensure that all samples and reagents are mixed well.

When doing microRNA analysis using Megaplex Primer Pools and TaqMan Array Cards, why are the Ct values for the endogenous controls highly variable across the sample set?

Highly variable values for endogenous controls is most likely due to biological variation. We recommend that you use an alternative endogenous control, such as a non-variable miRNA.

Why is the Ct value for the no-template control (NTC) <35 for some TaqMan microRNA Assays?

The Ct value for the NTC can be <35 for the following reasons:
- There are non-specific interactions between primers. For NTC information on a specific assay, see the Megaplex Assay Performance File.
- The cDNA template is contaminated. Please ollow established PCR good laboratory practices to prevent contamination.
- The preamplification product was not diluted properly before real-time PCR. Ensure that you dilute the preamplification product according the procedure in the user guide.

Why can I not detect any miRNA in my sample using the TaqMan MicroRNA Assay?

Most likely, the threshold is set too high to detect miRNA in samples with low levels of expression. We recommend adjusting the threshold (Ct) or NOAMP flag threshold (Crt) to an appropriate level.