Immuno 透明标准板
Immuno 透明标准板
Actual product may vary
Thermo Scientific™

Immuno 透明标准板

使用 Immuno 透明标准模块实施各孔之间可重复的应用。与标准设备配套。
Have Questions?
更改视图buttonViewtableView
货号表面处理工作容积(公制)孔形孔设计
467679PolySorp350 μL圆形F16
434797MaxiSorp350 μL圆形F8
441254PolySorp250 μLCC8
441653MaxiSorp250 μL圆形C8
444865PolySorp250 μL圆形C8
445101MaxiSorp250 μL圆形C8
467120MediSorp350 μL圆形F8
467140MultiSorp350 μL圆形F8
467466MaxiSorp350 μL圆形F16(2 x 8 孔)
468667MaxiSorp350 μL圆形F8
469078PolySorp350 μL圆形F8
469264亲水250 μLU 形U16
469914MaxiSorp350 μL圆形F16(2 x 8 孔)
469922PolySorp350 μL圆形F16(2 x 8 孔)
469949MaxiSorp350 μL圆形F8
469957PolySorp350 μL圆形F8
473709MaxiSorp250 μL圆形C12
473717PolySorp250 μL圆形C12
475078MaxiSorp250 μLU 形U8
475086PolySorp250 μLU 形U8
6302Immulon 2 HB330 μL圆形F12
6309Immulon 2 HB330 μL圆形F12
6310Immulon 1 B330 μL圆形F12
6405Immulon 4 HBX330 μL圆形F12
95029100增强结合350 μL圆形F8
6301TS1
又称 6301
Immulon 1 B330 μL圆形F12
货号 467679
价格(CNY)
2,766.72
飞享价
Ends: 31-Dec-2025
5,533.45
共减 2,766.73 (50%)
Case of 60
添加至购物车
表面处理:
PolySorp
工作容积(公制):
350 μL
孔形:
圆形
孔设计:
F16
价格(CNY)
2,766.72
飞享价
Ends: 31-Dec-2025
5,533.45
共减 2,766.73 (50%)
Case of 60
添加至购物车

Thermo Scientific™ Immuno 透明标准板具有为 ELISA 技术开发的 Nunc™、Immulon™ 和 Microtiter™ 模块板,孔与孔之间重复性良好。这些板可与标准设备配套,有助于灵活应用使用小样品量的组件。它们具有行业领先的质量标准和认证的支持。

特点:

  • 几种可拆板条规格:8 孔可拆, 12 孔可拆, 16 孔可拆板条(两排 8 孔可拆板条)
  • 几种孔形:平底,C 型底(平底折角),U 形孔,星形孔(孔内带凸棱,以增加表面积和增强性能)
  • 几种表面修饰,最大程度提升测定性能
  • 翻转过来时,可拆条仍可固定在框架里
  • 框架可堆叠,有方便盖子定位的标记
  • 聚苯乙烯板条,聚乙烯框架
  • 外部尺寸:128 × 86mm

可选表面:

  • Thermo Scientific™ PolySorp™、Immulon™ 1B 和通用结合 (UB) 产品,适用于吸附疏水分子。
  • Thermo Scientific™ Medisorp™ 和 Immulon 2HB 有轻微亲水性,可结合多种生物分子。
  • Thermo Scientific™ MaxiSorp™、Immulon 4 HBX 和增强结合 (EB) 产品具有亲水性,适用于抗体夹心法测定。
  • Thermo Scientific™ MultiSorp™ 表面非常亲水,非常适合多糖和水溶性蛋白。

订购信息:

可拆条为独立式。货货号 95029440 和 464394 有证书。框架和可拆条可单独购买。提供密封膜和硅胶盖。可根据要求提供不同颜色的可拆条。更多详情,请联系您的客户服务或销售代表。

对内部研究使用限制的免责声明:关于买方仅可将产品用于内部研究的任何限制事项并不适用于与此声明相关的网页上的产品。
规格
结合属性疏水
转折点
认证级
检测方法比色法
无盖
每箱数量60
每架数量10
包装60 箱,10 包
板封闭
产品类型框架
靶标分子脂质
工作容积(公制)350 μL
孔设计F16
颜色透明
产品规格单条可拆
材质聚苯乙烯
孔数量16
表面处理PolySorp
孔容积(公制)400 μL
孔形圆形
Unit SizeCase of 60

常见问题解答 (FAQ)

What frames do you recommend for your Immuno Clear Standard Modules?

We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

Which surfaces do you recommend for RIA (radioimmunoassay)?

The choice of plates or modules will depend on the type of RIA you are planning to perform and specific assay conditions. Nunc provides two different surfaces for immunoassays, PolySorp and MaxiSorp.
- MaxiSorp surface is highly charged and should be used if the assay requires quantitative measurement of proteins (antibodies) or molecules with polar groups.
- PolySorp surface should be used if the assay consists of less polar molecules with hydrophobic characteristics.

Which 96-well Immuno plates or modules do you recommend for various applications?

The following list offers a brief description of the features of Nunc products and their specific applications:
- Nunc-Immuno Plates, MaxiSorp surface - These plates are designed for solid phase immuno assays and have a polystyrene surface with high affinity for polar groups and hydrophilic molecules. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
- Nunc-Immuno Plates, PolySorp surface - These plates have a polystyrene surface which adsorps less polar molecules compared to the MaxiSorp surface and has a high affinity for hydrophobic groups. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
- Nunc-Immuno Modules - These modules are designed for solid-phase immuno assays. The modules are available in 8-, 12- or 16-well formats with (F), (U), and (C) bottom-well and 8-well BreakApart with (C) bottom-well designs. These different formats allow one to choose the style which is appropriate for their assay design.
BreakApart Modules and LockWell Modules can be used for radioimmunoassays.
- Nunc StarWell Immuno Breakable Modules - The 8-well modules feature eight fins on the inner wall of the (C) bottom wells. This design increases the surface area by 50%. The increase in surface area allows more molecules to be immobilized, increasing assay signal. The fin configuration provides shorter diffusion distance to the surface, reducing incubation times.
- LockWell Immuno Breakable Modules - Each plate consists of 1 x 8 breakable strips. These strips are assembled in a designed frame which locks each well into place by a spring lock. This spring lock design orientates each well at the same horizontal level allowing uniform washing and reading. The LockWell Modules are available with round (U), (C) or StarWell bottom-well designs.
- Plates and Modules with (CovaLink) Covalent Binding Surfaces: These plates can be used to bind proteins, peptides, DNA or carbohydrates. Covalent linkage occurs via secondary amine group. This allows a specific orientation and provides improved stability compared to passive adsorption due to chemical binding between molecules. Binding of molecules on PolySorp and MaxiSorp surfaces is obtained by passive adsorption. CovaLink is a surface grafted with secondary amino groups (<NH) which serves as a bridge for covalent coupling. The covalent binding can immobilize small molecules such as biotin or peptides which may otherwise bind weakly by physical adsorption and facilitate the recognition by detection molecule.
- Nunc FluoroNunc/LumiNunc 96-Well Plates: These plates are optimized for IFMA (Immunofluorometric Assays) or FIA (Fluorometric Immuno Assays). The transparent polystyrene plates give a low background fluorescence and are optimal where a read-through system is used. The white plates/modules provide maximum reflection of fluorescence signal while maintaining low background. The white plates/modules are often used for epifluorescence reading. Black modules reduce background fluorescence and minimize back-scatter light which is often encountered in epifluorescence.