384 孔微孔板,240μL,方形-圆形,8mm 直径,U 形底;6 件装
384 孔微孔板,240μL,方形-圆形,8mm 直径,U 形底;6 件装
Thermo Scientific™

384 孔微孔板,240μL,方形-圆形,8mm 直径,U 形底;6 件装

使用这些玻璃涂层孔板对需要玻璃样品瓶的样品进行高通量分析。

Have Questions?
货号反应孔总容量(公制)
60180-P342240 μL
货号 60180-P342
价格(CNY)
3,636.40
飞享价
Ends: 31-Dec-2025
5,124.72
共减 1,488.32 (29%)
Pack of 6
添加至购物车
反应孔总容量(公制):
240 μL
价格(CNY)
3,636.40
飞享价
Ends: 31-Dec-2025
5,124.72
共减 1,488.32 (29%)
Pack of 6
添加至购物车

需要玻璃样品瓶的样品现在可以从使用这些玻璃涂层孔板的高通量分析中受益。第二代 Thermo Scientific™ WebSeal™ Plate+ 玻璃涂层塑料孔板解决方案用于纯化塑料孔板,后者会引起溶剂稳定性变差或者塑料孔壁吸附导致产品损失。Webseal Plate+ 产品采用先进技术进行玻璃涂层,实现更高密度涂层(厚度 200 Å),改善了溶剂稳定性和可重现性,尤其对于吸附在塑料孔壁上的生物分子。

  • 为重要的极性化合物提供超低孔壁表面吸附率
  • 为强吸附分析物提供超痕量水平分析
  • 提供极高可重现性

更高的有机溶剂稳定性
通常只能在玻璃样品瓶中处理的样品,现在具备了在高通量孔板中进行处理的优势。

重要化合物的腔壁吸附率更低
腔壁吸附是生物分析中结果不可重现的第 1 大原因。由于 Webseal Plate+ 孔板壁的极性已颠倒,吸附风险显著降低。

更高的可重现性
降低了样品损失的风险。

规格
认证级Specification Certified
高度(公制)22 mm
板尺寸Mid-well
温度范围(公制)-80°C to 121°C
反应孔总容量(公制)240 μL
工作容积(公制)180 μL
数组16 x 24
颜色Clear
材质聚丙烯
孔数量384
产品线SureSTART WebSeal Level 3
无菌Non-sterile
表面处理Glass-coated
孔形圆形方形
Unit SizePack of 6

常见问题解答 (FAQ)

Are bar-coded WebSeal plates available?

Yes, bar-coded WebSeal plates are available as a catalog product for the famly of Thermo Scientific Vanquish UHPLC machines only. However, plates can be provided with a pre-printed adhesive label applied. Contact your sales representative to assist with completing a form where you can define the bar code information and location of application onto the plate. Additional information required includes the physical requirements for the label such as temperature stability, solvent stability, etc.

What is the best way to seal a WebSeal Plate plus or plates with glass or PTFE inserts that need to be incubated at elevated temperatures?

WebSeal Plate+ or plates with glass or PTFE inserts should never be sealed with tapes or adhesive foils. Silicone mats should be used with the WebSeal Plate&plus products, preferably with a protective PTFE film to give increased chemical protection.

The glass inserted plates are sealed with specific silicone plug mats or individual caps. Again, most have additional PTFE films of layers to give increased chemical protection.

These plates, inserts, and mats were originally designed for combinatorial chemistry techniques with in situ chemical derivatization. Use with elevated temperatures is possible with the inserts and plugs. These are the closest plate format equivalent to glass autosampler vial products.

How do the Thermo Scientific-WebSeal Plate plus products compare to standard and certified products?

The WebSeal Plate+ coating provides additional surface protection that further reduces the possibility of interactions with solvents, sample component, or other materials. WebSeal Plate+ microptates display ultra-low background extractable organics profiles that compare favorably to our mass spectrometry certified vial products.

How do WebSeal-Certified low bleed plates compare to others?

Well plates are manufactured in molds. In order to ''force'' the ready produced plate to come out of this mold for the next shot, some manufacturers use release agents (organic compounds that act as lubricants). These release agents can be detected in your chromatogram. The grade of polypropylene used by most plate manufacturers can contain monomers or other added ingredients that are susceptible to leaching on contact with organic solvents. WebSeal-Certified products are manufactured from high purity resins and use a process that does not require mold release agents and that is why they exhbit no significant background extractables.

Do standard WebSeal plates bleed with organic solvents, or is it better to purchase certified plates?

If you are using high concentrations of organic solvents in your sample, then you may be concerned about ''bleed''. This is a term which normally implies a constant loss of material from the column or separation system which leads to high background levels, increased noise, and loss of sensitivity. If using solutions with a high level of buffer or water, then this should not be a concern as such components will not leach under these conditions. All plates may be used.

The evaluation of the plastic resins used in the production of plates was also carried out by controlled extraction of leachable components with organic solvents associated with HPLC and GC operation. These included methanol, acetonitrile, and hexane. Standard plates showed low level of extractables when tested at the highest instrument sensitivity range. These extractables found are characteristic of the common materials used for microplates in the clinical market and plates that have been used for general purpose chromatography applications. This indicates that for many non-critical applications and with higher concentrations of sample, the standard quality plates will be acceptable. These plates are termed Chromatography Tested.

The very low levels of background extractables found during our testing of some plates showed for applications run at more sensitive instrument settings. Where higher purity of the plate is required, you should directly switch to the Certified plates as they are the lowest extraction PP plates currently available on the world market. For critical analysis with high organic solvent concentrations and low sample concentrations, the Certified product range should be the plates of choice.