Versette™ 自动移液工作站
Actual product may vary
Thermo Scientific™

Versette™ 自动移液工作站

此款紧凑型处理系统具有用户友好型编程、可靠的性能和及可选 96 或 384 通道移液头,可支持广泛的应用。
Have Questions?
货号描述
650-MSIAVersette system for MSIA application (includes base, pipetting module, 6-position stage, 96-channel pipetting head for volumes of 5-300μl and a serial dilute magazine 96/300μl)
货号 650-MSIA
价格(CNY)
-
描述:
Versette system for MSIA application (includes base, pipetting module, 6-position stage, 96-channel pipetting head for volumes of 5-300μl and a serial dilute magazine 96/300μl)

Thermo Scientific™ Versette™ 自动移液工作站为紧凑型处理系统,具有用户友好型编程、可靠的性能和及可选 96 或 384 通道移液头,可支持广泛的应用。大多数实验室的液体处理需求的理想选择,支持 96/384 孔板复制、板标记和梯度稀释程序。

应用范围广,包括高通量质谱免疫分析 (MSIA)、板复制、板式重排、梯度稀释及许多其他应用。

96 和 384 通道移液头:

  • 总体积范围 0.5-300μL
  • 所有移液头包含 RFID 标签以供自我识别

可优化性能的耗材:

  • 所有移液头采用 Thermo Scientific™ D.A.R.T.'S枪头

体积小巧:

  • 六位操作台采用了独特的双层式设计,以最大限度地减少空间
  • 可放在标准工作台和生物安全柜内使用

用户友好编程选项:

  • 通过使用仪器自带的可视化图形显示屏,可创建简单的移液程序
  • Thermo Scientific™ ControlMate™ 软件可提供更复杂的高级编辑方案
规格
深度(英制)22 in.
深度(公制)55 cm
描述Versette system for MSIA application (includes base, pipetting module, 6-position stage, 96-channel pipetting head for volumes of 5-300μl and a serial dilute magazine 96/300μl)
电气要求100 至 240V 50/60Hz
适用于(设备)不同高度的 96-、384- 孔板,盒装的储存管(赛默飞 0.5 至 1.4mL)
频率50/60 Hz
高度(英制)27 in.
高度(公制)68 cm
界面RS-232、USB
操作系统Windows XP、Windows Vista(32 位及 64 位)、Windows 7(32 位及 64 位)、WIN 10
电压100/240 V
重量(英制)120 lb. (base system - heads/pipetting module not included), 80 lb. (base - tower), 40 lb. (6 position stage), 26 lb. (NTC pipetting module)
重量(公制)54.4 kg (base system - heads/pipetting module not included), 36 kg (base - tower), 18.1 kg (6 position stage), 11.8 kg (NTC pipetting module)
宽度(英制)27 in.
宽度(公制)68 cm
通道96, 384
产品类型Versette System
容积(公制)0.5 至 300 μL
Unit SizeEach

常见问题解答 (FAQ)

Which components for the Versette Automated Liquid Handler have serial numbers?

Serial numbers are listed on the three individual components which make up the complete instrument: base unit, six position stage, and 96/384 pipetting module. Additionally, the pipetting heads and the peristaltic pump have serial numbers for traceability.

What is the maximum volume held by each Automation Reservoir used with the Versette Automatic Liquid Handler?

The maximum volumes for the Automation Reservoirs are as follows:

- 96-channel reservoirs hold a minimum of 95 mL w/ baffle and 125 mL w/o baffle
- 96-channel DW reservoirs hold a minimum of 160 mL w/baffle and 220 mL w/o baffle
- 384-channel reservoirs hold a minimum of 65 mL w/baffle and 95 mL w/o baffle

What are the minimum (dead) volumes for the Automation Reservoirs used with the Versette Automatic Liquid Handler?

The minimum dead volumes for the Automation Reservoirs are as follows:

- 96-channel reservoirs: 5 mL
- 384-channel reservoirs: 4 mL

Does the Versette Automated Liquid Handler have liquid level detection?

No, liquid level detection is not available on the Versette Automated Liquid Handler.

What would happen if the wrong pipetting head is installed in the Versette Automated Liquid Handler?

The Versette Automated Liquid Handler incorporates RFID technology to identify which pipetting head is installed in the system. The protocol will prompt the user to check/change the head if the wrong head is installed for a specific protocol being run.