POROS™ HQ 50 μm 强阴离子交换树脂
POROS™ HQ 50 μm 强阴离子交换树脂
Thermo Scientific™

POROS™ HQ 50 μm 强阴离子交换树脂

POROS™ 50-微米树脂可供在低压条件下应用,包括用于大规模的下游生物制备。POROS HQ 因具有季铵化的聚乙烯亚胺官能团而具有高容量,Perfusion Chromatography™ 专门针对生物分子的分离和纯化而设计。POROS Perfusion Chromatography了解更多信息
Have Questions?
更改视图buttonViewtableView
货号容积(公制)
8207710 mL
8207850 mL
货号 82077
价格(CNY)
2,286.00
Each
添加至购物车
容积(公制):
10 mL
请求批量或定制报价
价格(CNY)
2,286.00
Each
添加至购物车
POROS™ 50-微米树脂可供在低压条件下应用,包括用于大规模的下游生物制备。POROS HQ 因具有季铵化的聚乙烯亚胺官能团而具有高容量,Perfusion Chromatography™ 专门针对生物分子的分离和纯化而设计。

POROS Perfusion Chromatography 树脂

一种用于大量分离处理分析的高效色谱树脂。
•更高的工作效率—Perfusion Chromatography 相关的高通量和高动态容量
•化学稳定性—允许过度清洗和消毒
•提供增强的生物分子—通过大孔径提供,范围为 500-10000Å
• 聚苯乙烯二乙烯基苯微粒—提供稳定的、易于填充的基质
• 可在更短的时间内研发更好的分离方法—Perfusion Chromatography 技术以其快速的特点将实验工作时间由数周降至仅几小时,这将使您有充分的时间来探究分离工作的所有变量

减少耗时的样品制备工作

您可通过高速 Perfusion Chromatography 技术代替多种样品制备步骤。比如,采用高流速处理稀释样品来替代使用大量物质的透析。在少量新缓冲液中洗脱可以实现缓冲液交换和浓度。

创建新的分析方法以提高分析效率

Perfusion Chromatography 技术并不局限于标准分离模式。酶和亲和配体都可被固定于POROS 介质上。通过将快速柱上蛋白酶切与快速柱上免疫检测和色谱分离相结合,可创建具有无限潜力的全新检测方法。

高容量、高分离度、高速
与传统色谱基质相比,POROS 灌注色谱树脂粒子设计有两类细微孔。较大“通孔”可通过粒子本身发生对流流动,将样品分子快速地运载至短“扩散”孔内部。通过减少发生扩散的距离,也减少了样品分子与内部结合位点相互作用需要的时间。扩散将不再被限制而流速会显著提高—同时不影响分辨率和容量。与传统树脂的 50 至 360 cm⁄h 的分离速度相比,其分离速度可达 1,000 至 5,000 cm⁄h。
仅供科研使用。不可用于诊断程序。
规格
适用于(应用)生物分子的分离和纯化
产品规格Poros 微球
产品线POROS™
纯化目标蛋白质
数量10 mL
运输条件室温
标准组分季铵化聚乙烯亚胺
固定相季铵化聚乙烯亚胺
容积(公制)10 mL
类型HQ 强阴离子交换树脂
Unit SizeEach
内容与储存
储存在冰箱 (2–8°C) 中。

常见问题解答 (FAQ)

Are POROS analytical columns compatible with HPLC systems from Waters or Agilent?

All of the pre-packed POROS columns, regardless of column size or resin, have the same 10-32 female fittings on the column. Columns are compatible with Waters and Agilent HPLC systems. You will need 1/16 inch male fittings for the HPLC to attach the column.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

For any POROS analytical column, is the column compatible with an AKTA or Avant purification system?

All of the pre-packed columns, regardless column size or resin, have the same 10-32 female fittings on the column. They are all compatible with the AKTA instrument platform, however due to the column volume of the 2.1 mmD x 30 mmL columns (0.1 mL), these will not perform well in AKTA or Avant purification systems due to the relative size of the hold- up volume in these systems. The smallest column (PEEK or SS) that could feasibly be used in these systems is the 4.6mmD x 50mmL (0.8 mL) format.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

What is the physical or mechanical stability of POROS resins?

The physical stability of POROS resins is high. Customers have agitated, with overhead mixing and or bottom gassing for long periods of time (5-10 hours) and have performed hundreds of diaphragm pump passes during stall packs. Keep in mind that agitation with any device that creates grinding and sheer, such as with a magnetic stir bar, is not recommended for any type of resin.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

What should I do if a POROS column dries out or air is pumped onto the column?

POROS resins rehydrate quite well. Here is the procedure that we recommend:

1. Flow 5% ethanol over the column at ?350 cm/hour for 3 CVs, followed by water or 0.1 M sodium chloride at 300 cm/hour for 3 CVs.
2. If baseline noise is still present, flow 20% ethanol over the column at 300 cm/hour for 3 CVs, followed by water or 0.1 M sodium chloride at 300 cm/hour for 3 CVs.
3. If you have established column qualification tests and specifications, perform the tests after rewetting.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

Can POROS resins be used to purify large biomolecules?

In general POROS resins have behaved better for large biomolecules such as viral particles, fusion proteins, and globular proteins, where shape (not size) matters due to its unique pore structure and large pore structure as compared to traditional resins. As the target molecule size increases, capacities obtained will decrease. The large pore structure of POROS resins, which allows for convective flow (and therefore enhanced diffusion) is especially well suited for the purification of large biomolecules. POROS resins offer the best blend of high capacity (associated with chromatography beads) and improved chromatography efficiency (typically associated with monoliths or membranes). The average pore size for POROS resins is 1,000-3,600 Angstrom (100-360 nm) depending on the base bead/chemistry being utilized. For example, the molecular weight of IgG is 150 kDa and the molecular radius is 55 Angstrom. The molecular weight of IgM is ~900 kDa (pentamer), and the molecular radius is 120 Angstrom. So both of these biomolecules can interact with the pore structure associated with POROS materials.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.