Thermo Scientific™ iodoTMT Isobaric Label Reagents and Kits
Thermo Scientific™ iodoTMT Isobaric Label Reagents and Kits
Thermo Scientific™ iodoTMT Isobaric Label Reagents and Kits
Thermo Scientific™ iodoTMT Isobaric Label Reagents and Kits
Thermo Scientific™ iodoTMT Isobaric Label Reagents and Kits
Thermo Scientific™

Thermo Scientific™ iodoTMT Isobaric Label Reagents and Kits

Use Iodoacetyl Tandem Mass Tag (iodoTMT) Isobaric Label Reagents to label sulfhydryl-containing peptides for the multiplexed detection and quantitation of cysteine modification using tandem mass spectrometry analysis.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberQuantityProduct Type
901025 x 0.2 mg (per tag)Isobaric Label Reagent Set
901005 x 0.2 mgLabel Reagent
901011 x 0.2 mg (per tag)Isobaric Label Reagent Set
Catalog number 90102
Price (CNY)
33,645.00
Each
Add to cart
Quantity:
5 x 0.2 mg (per tag)
Product Type:
Isobaric Label Reagent Set
Request bulk or custom format
Price (CNY)
33,645.00
Each
Add to cart

Thermo Scientific iodoTMT Label reagents enable multiplexed identification and quantitation of cysteine containing peptides in different samples using tandem mass spectrometry. IodoTMT reagents are sets of isobaric (mass and structure) isomers that are iodoacetyl-activated for covalent, irreversible labeling of sulfhydryl (–SH) groups. iodoTMTzero Label Reagent allows testing and optimization of sample preparation, labeling, fractionation, and MS fragmentation for peptide identification and reporter detection without using the more costly isotope-labeled compounds.

Iodoacetyl tandem mass tag reagents enable selective labeling of cysteine-containing peptides for multiplexed sample quantitation using LC-MS/MS analysis. Similar to iodoacetamide, iodoTMT reagents react specifically with reduced cysteines (Cys) in peptides and proteins and enable quantitation of the relative abundance of cysteine modifications, such as S-nitrosylation and the oxidation of disulfide bonds. IodoTMT reagents irreversibly label free sulfhydryl groups on cysteine residues, in contrast to previous reversible cysteine-reactive TMT (cysTMT) reagents.

To selectively analyze the cysteine-labeled peptides, the sample may be enriched using Immobilized Anti-TMT Antibody Resin (Cat. No. 90076) and TMT Elution Buffer (Cat. No. 90104). This approach of selective thiol-labeling and affinity enrichment is similar to isotope-coded affinity tags (ICAT method) but allows for affinity enrichment with a non-biological tag and higher multiplex quantitation.

Features of iodoTMT reagents
Specific—only reacts with sulfhydryl groups (reduced, unmodified cysteine residues)
Irreversible—labeled proteins and peptides are not susceptible to reducing agents
Flexible—options for duplex isotopic (MS) or sixplex isobaric (MS/MS) quantitation
Versatile—can be used to study cysteine modifications (e.g., di-sulfide bridges, S-nitrosylation)

For Research Use Only. Not for use in diagnostic procedures.

General References:

Thompson, A., et al. (2003). Tandem mass tags: a novel quantification strategy for comparative analysis of complex protein mixtures by MS/MS. Anal. Chem. 75:1895-204.

Forrester MT, et al. (2009). Detection of protein S-nitroylsation with the biotin technique. Free Radic Biol Med. 46(2):119-126.

Gygi, S.P., et al. (1999). Quantitative analysis of complex protein mixtures using isotopecoded affinity tags. Nat. Biotech. 17:994-9.

Murray CI, et al. (2012) Identification and quantification of S-nitrosylation by cysteine reactive tandem mass tag switch assay. Mol Cell Proteomics. 11(2): M111.013441.

Yao, C., et al. (2013). Proteomic study of reversible cysteine oxidation in catalase overexpressing mice on a western diet. FASEB J, Apr 2013; 27:810.3.

Specifications
Final Product TypeProtein
For Use With (Equipment)Mass Spectrometer
Label or DyeTandem Mass Tag™ (TMT) Labels
Quantity5 x 0.2 mg (per tag)
Workflow StepProtein Labeling
Detection MethodMass Spectrometry
Product LineiodoTMTsixplex™
Product TypeIsobaric Label Reagent Set
Starting MaterialCell Lysate
Unit SizeEach
Contents & Storage
Sufficient for: Five sixplex (5 x 6-way) experiments
• iodoTMT6-126 Label Reagent, 5 x 0.2 mg
• iodoTMT6-127 Label Reagent, 5 x 0.2 mg
• iodoTMT6-128 Label Reagent, 5 x 0.2 mg
• iodoTMT6-129 Label Reagent, 5 x 0.2 mg
• iodoTMT6-130 Label Reagent, 5 x 0.2 mg
• iodoTMT6-131 Label Reagent, 5 x 0.2 mg

Store at –20°C.

Frequently asked questions (FAQs)

What is the difference between IodoTMT tags and Iodoacetamido-LC-Phosphonic Acid?

Both IodoTMT tags and Iodoacetamido-LC-Phosphonic Acid react with sulfhydryl groups. Iodo TMT tags allow the quantitation of proteins with cysteine amino acids and the oxidative state of sulfhydryl groups, while Iodoacetamido-LC-Phosphonic Acid allow the detection and enrichment of those specific proteins. This is a great tool for mass spectrometry (MS) analysis, and High-Select Fe-NTA Magnetic Phosphopeptide Enrichment Kit (Cat. No. A52283), can be used for the enrichment step.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.