Oncomine™ Immune Response Research Assay-自动化
Oncomine™ Immune Response Research Assay-自动化
Ion Torrent™

Oncomine™ Immune Response Research Assay-自动化

The Oncomine™ Immune Response Research Assay is a targeted gene expression assay designed for the Ion™ next-generation sequencing (NGS) platform.了解更多信息
Have Questions?
货号数量
A3292832 Samples
货号 A32928
价格(CNY)
-
申请报价
数量:
32 Samples
The Oncomine™ Immune Response Research Assay is a targeted gene expression assay designed for the Ion™ next-generation sequencing (NGS) platform. This pan-cancer gene expression assay is designed to interrogate the tumor microenvironment to enable mechanistic studies and identification of predictive biomarkers for immunotherapy in retrospective or prospective clinical trial research cohorts. The assay is optimized to measure the expression of genes involved in tumor-immune interactions, including the low-expressing genes involved in inflammatory signaling.

This assay contains the reagents for automated library construction using the Ion Chef™ System and a single pool of primers used to perform multiplex PCR for preparation of amplicon libraries from formalin-fixed paraffin-embedded (FFPE) samples. The assay enables quantitative evaluation of the expression of markers associated with different leukocyte subsets, antigen presentation, checkpoint pathways, and tumor progression. This 400-gene assay is supported with a user-friendly informatics workflow and demonstrates high sensitivity for low-expressing transcripts derived from FFPE samples (request a gene list). The Oncomine Immune Response Research Assay leverages Ion AmpliSeq™ technology to deliver results from as little as 10 ng of total RNA, enabling robust performance from challenging FFPE samples.

Assay workflow
The Oncomine Immune Response Research Assay automated workflow features high sample multiplexing on Ion S5™ sequencing systems. The entire workflow, from sample extraction to results, can be completed in less than 48 hours with less than 45 minutes of hands-on time from DNA to data, and only two pipetting steps per sample. Note: An alternate assay is available (Cat. No. A32881) for the preparation of Ion AmpliSeq libraries in manual mode without use of an Ion Chef System.

Assay performance
• High repeatability and sensitive detection of gene expression across different types of solid tumors
• Low sample input requirement (10 ng of total RNA material)
• High sensitivity detection of low-expressing signaling molecules such as interleukins and interferon gamma
• High sample multiplexing with flexibility to sequence 4, 8, or 32 samples per single run
• Automated workflow that offers sample-to-results in less than 48 hours, with less than 45 minutes hands-on time and only two pipetting steps
• Automated and seamlessly integrated analysis solution
• Interpretation of immune surveillance and tumor progression mechanism with functional annotation of genes and pathways

Informatics
The Oncomine Immune Response Research Assay comes with optimized informatics and visualization software that minimizes the complexity of data analysis. The analysis workflow consists of a data exploration component automated by the Immune Response Torrent Suite™ Plug-in and a two-group differential analysis provided by the Affymetrix™ Transcriptome Analysis Console (TAC). Together these tools offer a streamlined process for common gene expression analyses and exportable data files that are amenable to further exploration with other third-party software. Specifically, these tools provide:
• QC metrics and expression of housekeeping genes to qualify data
• Hierarchical clustering of samples with user-defined gene sets or by all genes on the panel
• Visualization with PCA, heatmaps, and gene expression distribution plots
• Sample correlation using rich correlation plots
• Fold-change estimates in easy-to-use tabular data format (TAC)
• Volcano plots to visualize differentially genes (TAC)

规格
产品规格96 孔板
引物AmpliSeq 引物
产品类型Immune Response Research Assay
数量32 Samples
通量32 个样品
产品线Oncomine™
原始材料RNA
Unit SizeEach
内容与储存
• Oncomine Immune Response Panel Chef-即用型试剂盒,储存于 -5 至 -30°C
• 4 盒 Ion AmpliSeq Chef 试剂 DL8,储存于 -5°C 至 -30°C
• 4 盒 Ion AmpliSeq Chef 溶液 DL8,储存于 2–8°C
• 4 箱 Ion AmpliSeq 配套产品(每箱含:Ion AmpliSeq 吸头盒 L8、框式 PCR 铝箔密封、富集盒),在室温下储存
• 1 套 4 种 IonCode 用于不同的 PCR 板(该套件包括:Ion Code 0101-0108 96 孔 PCR 板(红色),Ion Code 0109-0116 96 孔 PCR 板(黄色),Ion Code 0117-0124 96 孔 PCR 板(绿色),Ion Code 0125-0132 96 孔 PCR 板(蓝色),室温储存

常见问题解答 (FAQ)

With the Oncomine Immune Response Research Assay, how many samples can I multiplex per run?

Multiplexing can be done with 1-4 samples on the PGM 318 or S5/S5XL 520 chips, or with 2-8 samples on the S5/S5XL 520 chip. This enables flexibility for small-to-large retrospective profiling studies.

Which RNA isolation method do you recommend for use with the Oncomine Immune Response Research Assay?

We recommend using the RecoverAll Total Nucleic Acid Isolation Kit for FFPE (Cat. No. AM1975).

Can I automate the Oncomine Immune Response Research Assay workflow?

Yes, automated library and template preparation are enabled with the Ion Chef System.

Where can I find the User Guide for the Oncomine Immune Response Research Assay?

The User Guide can be found here (https://tools.thermofisher.com/content/sfs/manuals/MAN0015867_OncomineImmuneRespnseResrchAssay_UG.pdf).

What functional annotation groups are covered by the Oncomine Immune Response Research Assay?

The Oncomine Immune Response Research Assay content includes 395 genes across 36 functional annotation groups. These groups comprise genes associated with lymphocyte regulation, cytokine signaling, lymphocyte markers, checkpoint pathways, and tumor characterization.