SuperSignal West Atto 超敏化学发光底物是一种超灵敏的增强型化学发光 (ECL) 底物,可用于高阿克级蛋白检测。SuperSignal West Atto 底物与其他市售高性能辣根过氧化物酶了解更多信息
Have Questions?
更改视图
货号
数量
A38555
100 mL
A38554
20 mL
A38556
200 mL
3 选项
货号 A38555
价格(CNY)
3,282.00
飞享价
Ends: 31-Dec-2025
4,606.00
共减 1,324.00 (29%)
Each
添加至购物车
数量:
100 mL
价格(CNY)
3,282.00
飞享价
Ends: 31-Dec-2025
4,606.00
共减 1,324.00 (29%)
Each
添加至购物车
SuperSignal West Atto 超敏化学发光底物是一种超灵敏的增强型化学发光 (ECL) 底物,可用于高阿克级蛋白检测。SuperSignal West Atto 底物与其他市售高性能辣根过氧化物酶 (HRP) 底物相比,可提供极高水平的灵敏度和极佳的信噪比。–SuperSignal West Atto 超敏化学发光底物特性包括:
SuperSignal West Atto 超敏化学发光底物设计用于在 Western 印迹分析中针对非常低丰度靶标或珍贵样品获得卓越敏感性和信噪比。当与优化的抗体浓度和封闭缓冲液结合使用时,SuperSignal West Atto 底物能够检测到低丰度靶蛋白,即使在含量低至使用典型高性能 ECL 底物也无法检出的水平时也可进行检测。
仅供科研使用。不可用于诊断程序。
规格
套装内容Luminol/Enhancer, 50 mL, Stable Peroxide Buffer, 50 mL
灵敏度低飞克至高阿克水平
运输条件湿冰
足够用于12次小型凝胶印迹,1000 sq. cm 膜
检测方法化学发光
适用于(应用)蛋白质免疫印迹
形式液体
膜兼容性硝酸纤维素、PVDF
产品线SuperSignal™
产品类型底物
数量100 mL
基质辣根过氧化物酶
Unit SizeEach
内容与储存
• 底物溶液,50 mL • 稳定过氧化物溶液,50 mL
足够用于 12 份微型凝胶印迹;1000 cm2 的膜。
在 2–8°C 下储存试剂。
常见问题解答 (FAQ)
How do I handle saturated or burned out bands using SuperSignal West Atto Ultimate Sensitivity Substrate?
Here are some suggestions:
- Shorten the time of exposure
- Wash blot and try using SuperSignal West Pico PLUS Chemiluminescent Substrate
- Strip the membrane using Restore Western Blot Stripping Buffer, re-probe with lesser amount of primary and secondary antibodies, and try first with SuperSignal West Pico PLUS Chemiluminescent Substrate
- Re-run the gel using lesser sample
How can I reduce background with SuperSignal West Atto Ultimate Sensitivity Substrate?
Here are potential causes for high background and corresponding solutions:
- Too much HRP in the system: Further dilute the HRP-conjugate, see guidelines in Table 1 in the user guide (https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0018858_SuperSignalWestAtto_UG.pdf).
- Inadequate blocking: Optimize blocking conditions.
- Inappropriate blocking reagent: Try a different blocking reagent. Use clear milk or StartingBlock blocking buffer instead of dry milk.
- Inadequate washing: Increase length, number or volume of washes.
- Film has been overexposed: Decrease exposure time or use Pierce Background Eliminator (Cat No. 21065).
- Concentration of antigen or antibody is too high: Decrease amount of antigen or antibody.
- Poor antibody specificity: Use SuperSignal Western Blot Enhancer (Cat. No. 46640).
We also recommend minimizing handling of the membrane, using clean gloves while handling, clean plasticware, glassware, forceps, or other contact surfaces. We also recommend trimming of the membrane to remove excess area.
When should I use SuperSignal West Atto Ultimate Sensitivity Substrate?
We recommend using SuperSignal West Atto Ultimate Sensitivity Substrate for detection of proteins in the following situations:
- For proteins with low concentration, not measurable by BCA or Bradford assays
- For low-abundance phosphorylated or glycosylated proteins
- For low-abundance membrane or nuclear proteins
- For low-abundance proteins being detected with a low-affinity antibody or when the antibody is precious
- When sample source is limited or when multiple conditions or assays are being tested on a single sample