Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Invitrogen17万+抗体限时买二赠一,靶点广,灵活用!
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL
Thermo Scientific™

Zeba™ 染料和生物素去除离心柱和过滤板,0.5–10 mL

Thermo Scientific Zeba 染料和生物素去除柱能够快速、高效地去除蛋白质样品中未反应的荧光染料、生物素、还原剂和交联剂。标记反应后去除游离染料通常困难且耗时,但对于染料-蛋白比值的精确测定至关重要。Zeba 染料和生物素去除树脂高度专业化,可产生卓越的蛋白质回收率,同时可有效去除未结合的荧光染料了解更多信息
Have Questions?
更改视图buttonViewtableView
货号数量产品规格容积(公制)
A443005柱15 mL 锥形离心柱5 mL
A44296S5柱15 mL 锥形离心柱0.5 mL
A4429625柱15 mL 锥形离心柱0.5 mL
A442972 x 25 个柱15 mL 锥形离心柱0.5 mL
A442985柱15 mL 锥形离心柱2 mL
A4429925柱15 mL 锥形离心柱2 mL
A4430125柱15 mL 锥形离心柱5 mL
A443025柱15 mL 锥形离心柱10 mL
A443035 x 5 个柱15 mL 锥形离心柱10 mL
A443042块板96 孔过滤板96-well
A443052 x 2 孔板96 孔过滤板96-well
货号 A44300
价格(CNY)
958.00
Each
添加至购物车
数量:
5柱
产品规格:
15 mL 锥形离心柱
容积(公制):
5 mL
价格(CNY)
958.00
Each
添加至购物车
Thermo Scientific Zeba 染料和生物素去除柱能够快速、高效地去除蛋白质样品中未反应的荧光染料、生物素、还原剂和交联剂。标记反应后去除游离染料通常困难且耗时,但对于染料-蛋白比值的精确测定至关重要。Zeba 染料和生物素去除树脂高度专业化,可产生卓越的蛋白质回收率,同时可有效去除未结合的荧光染料、生物素化试剂、还原剂和交联剂。使用适量的样品和缓冲液条件,几乎所有的荧光染料均可用这些柱去除。即使是稀释蛋白样品 (25 µg/mL) 也可成功处理以去除染料、生物素、还原剂和交联剂,并高效回收蛋白质 (>7 kDa)。单个 10 mL 染料和生物素去除离心柱可处理 2 至 4 mL 样品。不建议将该产品用于脱盐或缓冲液交换。

Zeba 染料和生物素去除柱的特点:
通用型—从蛋白溶液中去除未反应的荧光染料、生物素化试剂、交联剂、还原剂
高回收率—低结合树脂最大限度地提高蛋白质回收率
易于使用—没有繁琐的装柱或平衡处理过程
快速—在 15 分钟内进行小分子去除和蛋白回收
灵活—可选择离心柱和过滤离心板以满足各种需求

可用规格:
•离心柱:0.5、2、5 和 10mL
• 96 孔过滤板:预分配;可用于手动或自动纯化离心;可实现小规模、高通量纯化的快速、一致孔间和板间重复性

应用:
•特别适用于反应后样品纯化
•有效去除未结合染料、生物素、还原剂和交联剂,具有卓越的蛋白回收率
仅供科研使用。不可用于诊断程序。
规格
数量5柱
运输条件室温
容积(公制)5 mL
色谱柱类型具有专利技术的树脂
产品规格15 mL 锥形离心柱
产品线Zeba™
样品体积(公制)1–2 mL
Unit SizeEach
内容与储存
在冷藏冰箱 (2–8°C) 中储存。

常见问题解答 (FAQ)

Are Zeba Dye and Biotin Removal Spin Columns/Filter Plates compatible with mass spectrometry?

Zeba Dye and Biotin Removal Spin Columns/Filter Plates are not directly compatible with mass spectrometry.

Find additional tips, troubleshooting help, and resources within our Protein Dialysis, Desalting, and Concentration Support Center.

Have you tested the Zeba Dye and Biotin Removal Spin Columns/Filter Plates using fixed angle rotor and swinging bucket rotor centrifuges?

The performance of the Zeba Dye and Biotin Removal resin is not affected by the type of centrifuge rotor.

Find additional tips, troubleshooting help, and resources within our Protein Dialysis, Desalting, and Concentration Support Center.

How dilute can my protein sample be for using with Zeba Dye and Biotin Removal Spin Columns/Filter Plates?

Protein samples with as low a concentration as 25 µg/mL can be successfully processed with Zeba Dye and Biotin Removal Spin Columns/Filter Plates to remove dyes, biotin, reducing agents, and crosslinkers and to efficiently recover proteins (>7 kDa).

Find additional tips, troubleshooting help, and resources within our Protein Dialysis, Desalting, and Concentration Support Center.

When should I use Zeba Dye and Biotin Removal Spin Columns/Filter Plates?

Zeba Dye and Biotin Removal Spin Columns/Filter Plates enable fast and efficient removal of non-conjugated fluorescent dyes, biotin, reducing agents, and crosslinkers from protein samples. We have tested removal of the following:
- Alexa Fluor dyes: 488, 555, 647
- Dylight dyes: 488, 550, 650, 650-4x PEG
- Rhodamine dye
- Biotin
- Reducing agents: DTT, TCEP
- Crosslinker: BS3

Find additional tips, troubleshooting help, and resources within our Protein Dialysis, Desalting, and Concentration Support Center.