SuperSignal™ Western 印迹底物包,Femto + 试验大小 Atto
SuperSignal™ Western 印迹底物包,Femto + 试验大小 Atto
Thermo Scientific™

SuperSignal™ Western 印迹底物包,Femto + 试验大小 Atto

该底物包包含 SuperSignal West Femto 较大灵敏度化学发光底物 + 样品大小的 SuperSignal West Atto了解更多信息
Have Questions?
货号数量
A459161套
货号 A45916
价格(CNY)
3,764.00
飞享价
Ends: 31-Dec-2025
5,171.00
共减 1,407.00 (27%)
Each
添加至购物车
数量:
1套
价格(CNY)
3,764.00
飞享价
Ends: 31-Dec-2025
5,171.00
共减 1,407.00 (27%)
Each
添加至购物车
该底物包包含 SuperSignal West Femto 较大灵敏度化学发光底物 + 样品大小的 SuperSignal West Atto 超敏化学发光底物,可进行用于低丰度靶标的较新、较灵敏底物的试验和比较。

SuperSignal West Femto 较大灵敏度底物
Thermo Scientific SuperSignal West Femto 较大灵敏度底物是一种高灵敏度、增强型化学发光 (ECL) 底物,用于使用辣根过氧化物酶 (HRP) 通过 Western 印迹分析进行低飞克级蛋白水平检测。它经过优化,可检测低丰度和/或难以检测的靶标。

•灵敏度:低飞克级(中-介摩尔)
• 稳定性:4°C 下工作溶液可保持稳定 8 小时,试剂盒可保持稳定 1 年
• 兼容性:硝酸纤维素和 PVDF 膜
• 信号持续时间:长达 8 小时
• 推荐的一抗浓度:1:5,000 – 1:100,000 稀释度 (10 – 200 ng/mL)
• 推荐的二抗浓度:1:100,000 – 1:500,000 稀释度 (2 – 10 ng/mL)

查看完整产品信息›

SuperSignal West Atto 超敏化学发光底物
Thermo Scientific SuperSignal West Atto 超敏化学发光底物是一种超灵敏的增强型化学发光 (ECL) 底物,用于使用辣根过氧化物酶 (HRP) 通过 Western 印迹分析进行高阿克级蛋白水平检测。它设计用于非常低丰度靶标或使用珍贵样品或昂贵抗体时所需的较大灵敏度水平检测。

•灵敏度:低飞克级至高阿克级
• 稳定性:4°C 下工作溶液可保持稳定 8 小时,试剂盒可保持稳定 1 年
• 兼容性:硝酸纤维素和 PVDF 膜
• 信号持续时间:长达 4 小时
• 推荐的一抗浓度:1:1,000– 1:5,000 稀释度 (0.2–1.0 μg/mL)
• 推荐的二抗浓度:1:100,000 – 1:250,000 稀释度 (4 – 10 ng/mL)

查看完整产品信息›

仅供科研使用。不可用于诊断程序。
规格
灵敏度低飞克级(中-介摩尔)
运输条件经批准可在室温下或者湿冰或干冰上运输
足够用于12次小型凝胶印迹,1000 sq. cm 膜;2次小型凝胶印迹,200 sq. cm 膜
检测方法化学发光
适用于(应用)蛋白质免疫印迹
形式液体
膜兼容性硝酸纤维素、PVDF
产品线SuperSignal™
产品类型底物
数量1套
基质辣根过氧化物酶
Unit SizeEach
内容与储存
• 100 mL SuperSignal West Femto 试剂,在 2–8°C 下储存
• 20 mL SuperSignal West Atto 试剂,在 2–8°C 下储存

常见问题解答 (FAQ)

How do I handle saturated or burned out bands using SuperSignal West Atto Ultimate Sensitivity Substrate?

Here are some suggestions:
- Shorten the time of exposure
- Wash blot and try using SuperSignal West Pico PLUS Chemiluminescent Substrate
- Strip the membrane using Restore Western Blot Stripping Buffer, re-probe with lesser amount of primary and secondary antibodies, and try first with SuperSignal West Pico PLUS Chemiluminescent Substrate
- Re-run the gel using lesser sample

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

How can I reduce background with SuperSignal West Atto Ultimate Sensitivity Substrate?

Here are potential causes for high background and corresponding solutions:
- Too much HRP in the system: Further dilute the HRP-conjugate, see guidelines in Table 1 in the user guide (https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0018858_SuperSignalWestAtto_UG.pdf).
- Inadequate blocking: Optimize blocking conditions.
- Inappropriate blocking reagent: Try a different blocking reagent. Use clear milk or StartingBlock blocking buffer instead of dry milk.
- Inadequate washing: Increase length, number or volume of washes.
- Film has been overexposed: Decrease exposure time or use Pierce Background Eliminator (Cat No. 21065).
- Concentration of antigen or antibody is too high: Decrease amount of antigen or antibody.
- Poor antibody specificity: Use SuperSignal Western Blot Enhancer (Cat. No. 46640).
We also recommend minimizing handling of the membrane, using clean gloves while handling, clean plasticware, glassware, forceps, or other contact surfaces. We also recommend trimming of the membrane to remove excess area.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Is SuperSignal West Atto Ultimate Sensitivity Substrate compatible with Restore Western Blot Stripping Buffer?

SuperSignal West Atto Ultimate Sensitivity Substrate is compatible with Restore Western Blot Stripping Buffer.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

When should I use SuperSignal West Atto Ultimate Sensitivity Substrate?

We recommend using SuperSignal West Atto Ultimate Sensitivity Substrate for detection of proteins in the following situations:
- For proteins with low concentration, not measurable by BCA or Bradford assays
- For low-abundance phosphorylated or glycosylated proteins
- For low-abundance membrane or nuclear proteins
- For low-abundance proteins being detected with a low-affinity antibody or when the antibody is precious
- When sample source is limited or when multiple conditions or assays are being tested on a single sample

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Is SuperSignal West Atto Ultimate Sensitivity Substrate affected by freeze/thaw cycles?

SuperSignal West Atto Ultimate Sensitivity Substrate can tolerate up to 3 freeze/thaw cycles without significant loss in performance.