Search
Search
查看更多产品信息 Novex™ Hi-Density TBE Sample Buffer (5X) - FAQs (LC6678)
4 个常见问题解答
如果出现了轻微的浑浊,可以在110°C高压灭菌5分钟溶解沉淀。不要在原装的容器内灭菌。这样做不会对TBE的缓冲性质产生不良影响。
请参见以下配方。
TBE电泳缓冲液(5X):
Tris碱, 54.0 g
硼酸,27.5 g
EDTA(游离酸),2.9 g
加去离子水至1.0 L
Hi-Density TBE上样缓冲液(5X):
5X TBE电泳缓冲液(货号LC6675)),2 mL
Ficoll Type 400, 1.5 g
溴酚蓝,1 mL1%溶液
二甲苯青1 mL1%溶液
加去离子水至10.0 mL
If a slight turbidity develops, the fine precipitate can be dissolved by autoclaving for 5 minutes at 110°C. Do not autoclave in the container supplied. This treatment has no deleterious effect on the buffering properties of TBE.
Please see the recipes below:
TBE Running Buffer (5X):
Tris base, 54.0 g
Boric acid, 27.5 g
EDTA (free acid), 2.9 g
Deionized water to 1.0 L
Hi-Density TBE Sample Buffer (5X):
5X TBE Running buffer (Cat. No. LC6675), 2 mL
Ficoll Type 400, 1.5 g
Bromophenol blue, 1 mL of 1% solution
Xylene cyanol 1 mL of 1% solution
Deionized water to 10.0 mL