Thermo Scientific™ Nunc™ FluoroNunc™/LumiNunc™ 96 孔板
Thermo Scientific™ Nunc™ FluoroNunc™/LumiNunc™ 96 孔板
Thermo Scientific™ Nunc™ FluoroNunc™/LumiNunc™ 96 孔板
Thermo Scientific™ Nunc™ FluoroNunc™/LumiNunc™ 96 孔板
Thermo Scientific™ Nunc™ FluoroNunc™/LumiNunc™ 96 孔板
Thermo Scientific™

Thermo Scientific™ Nunc™ FluoroNunc™/LumiNunc™ 96 孔板

使用这类孔板进行定量和定性固相免疫检测(如 FLISA)和结合检测。
Have Questions?
更改视图buttonViewtableView
货号颜色
437796白色
437958Clear
货号 437796
价格(CNY)
2,836.35
Online Exclusive
Ends: 31-Dec-2025
5,672.69
共减 2,836.34 (50%)
Case of 60
添加至购物车
颜色:
白色
价格(CNY)
2,836.35
Online Exclusive
Ends: 31-Dec-2025
5,672.69
共减 2,836.34 (50%)
Case of 60
添加至购物车

使用 Thermo Scientific Nunc FluoroNunc 96 孔固相微孔板,进行定量和定性固相免疫检测(如 FLISA)和结合检测。Thermo Scientific Nunc Immuno 微孔板批次间的可靠性好,孔与孔之间的可重复性出色,达到行业领先质量标准并获得认证。

  • 微孔板外形符合 SBS 标准——可用于标准仪器
  • 提供平底或 C 型孔
  • 可选 PolySorp™ 或者 MaxiSorp™ 表面
  • 微孔板可选颜色:黑色、白色或透明
  • 经认证的结合均一性/可重复性

 

可选表面

  • PolySorp- 疏水表面,优先结合带有疏水结构域的生物分子

  • MaxiSorp- 亲水表面,经过优化,更利于结合 IgG,对其他有特殊亲水/疏水特性的蛋白和生物分子的结合力同样有所增强。提供已经/未经 IgG 结合检测的批次特异

  • 性能测试(对于透明微孔板,孔间变异系数小于 5%;对于有颜色微孔板,孔间变异系数小于 10%)。已经测试的产品配有证书

 

白色

  • 反射最大
  • 自发荧光和自发光最小

 

黑色

  • 荧光读数时背景最小
  • 背向散射光最小
  • 交叉影响最小

 

透明

  • 用于时间分辨荧光检测

兼容:

与用于 MicroWell™ 的微孔板盖、密封带和透气薄膜兼容

保修期:90 天

内部研究使用限制的免责声明:买方将本产品用于内部研究用途的任何限制仅仅不适用于与此声明有关的网页上的产品。
规格
结合属性亲水
结合类型吸附
认证/合规经 IgG 吸附认证;孔间 %CV 小于 10%。
培养面积2.5 cm2
检测方法化学发光
带盖
每箱数量60
每架数量5
包装60 箱
板封闭
产品类型塑料、无涂层、非无菌孔板
靶标分子抗体(糖蛋白)
工作容积(公制)250 μL
数组8 x 12
颜色白色
产品规格标准
材质聚苯乙烯
孔数量96
产品线Nunc
表面处理MaxiSorp
孔形圆形
Unit SizeCase of 60

常见问题解答 (FAQ)

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.

How can I reduce high background readings and non-specific binding, when performing ELISA using Nunc-Immuno MaxiSorp Plates?

Assay sensitivity depends strongly on efficient removal of non-specific reacting molecules. High background readings and coating instability can be minimized by addition of a blocking step after the first coating. The excess surface is then occupied by indifferent molecules.
We recommend washing three times after each coating step by using a solution of 0.15 M phosphate buffer (pH 7.2) with 0.2 M NaCl and 0.05% Tween 20.
For blocking, we recommend using 0.5% BSA, 1% casein or 1% gelatin in 0.15 M phosphate buffer (pH 8.2) or carbonate buffer (pH 9.6).