MeltDoctor™ HRM 校准标准品 (20X)
Product Image
Applied Biosystems™

MeltDoctor™ HRM 校准标准品 (20X)

Applied Biosystems® MeltDoctor™ HRM 校准标准品含有一组 DNA 模板和引物,与 PCR 试剂和染料混合时可用于制备热和光学高分辨率熔解曲线 (HRM)了解更多信息
Have Questions?
货号数量
44255621 mL
货号 4425562
价格(CNY)
5,470.00
Each
添加至购物车
数量:
1 mL
价格(CNY)
5,470.00
Each
添加至购物车
Applied Biosystems® MeltDoctor™ HRM 校准标准品含有一组 DNA 模板和引物,与 PCR 试剂和染料混合时可用于制备热和光学高分辨率熔解曲线 (HRM) 的校准板。
仅供科研使用。不可用于诊断程序。
规格
已校准染料HRM(高分辨率熔解)染料
校准类型热校准,光学校准
最大浓度20 X
适用于(应用)实时 PCR (qPCR)
适用于(设备)7500 Fast 系统、7900HT Fast 系统
产品规格管装
产品线MeltDoctor™
数量1 mL
运输条件湿冰
产品类型HRM 校准标准品
Unit SizeEach
内容与储存
1 管含 1 mL DNA 模板和引物 20X 溶液,与 PCR 试剂和染料混合时可用于制备热和光学高分辨率熔解曲线 (HRM) 的校准板。
-15°C 至 -25°C 储存

保质期至少 60 天(确切的有效期已印在产品和分析证书上)。

常见问题解答 (FAQ)

How long should the amplicon be for HRM analysis?

We recommend to use 50-250 bp long PCR amplicons. Typically, shorter amplicons can distinguish the genotypes for a SNP better, especially for Type III and Type IV SNPs. This is simply because a single base variation affects the melting behavior of a 100 bp amplicon stronger than of a 500 bp amplicon, for example. In longer fragments, the risk of covering multiple mutations is also increased.

What can be used as positive control reactions in HRM analysis?

Positive control reactions should contain template DNA with a known sequence. In SNP genotyping experiments, this could be a sample with a known genotype. Positive control(s) for all genotypes should be included where possible to serve as a reference in melting curve comparison and assigning genotypes for test samples. In mutation scanning experiments, a sample with a wild type sequence could serve as a positive control. The controls should preferably have the same DNA concentration as their corresponding test samples. Control DNA should also be eluted and/or diluted in the same buffer as the samples.

In HRM analysis, when is it better to use a 3-step cycling protocol rather than a 2-step protocol?

A 3-step cycling protocol is recommended for the analysis of complicated (especially Type IV SNP) targets, amplicons longer than 200 bp, and amplicons with a primer annealing temperature that is less than 60 degrees C.

The HRM software will not accept my calibration file. What is wrong?

Check that there are no outliers on the plate. You cannot omit any wells on the HRM calibration plate.

I have a 7900HT Fast Real-Time PCR System, and cannot open the data file in HRM software. What could be causing this?

There are a few possibilities. First, make sure the HRM Software version is v2.0.1, and the 7900HT Fast Real-Time PCR System software version is v2.3 or above. Second, check that the run method used was as recommended in the HRM protocol; make sure the ramp rate for the dissociation stage is 1%. Then try to open the calibration file from the HRM Software; if it does not open, the calibration file is defective. The defects could be due to a bad calibration plate or instrument uniformity issue.