Immuno 透明标准板
Immuno 透明标准板
Immuno 透明标准板
Immuno 透明标准板
Immuno 透明标准板
Thermo Scientific™

Immuno 透明标准板

使用 Immuno 透明标准模块实施各孔之间可重复的应用。与标准设备配套。
Have Questions?
更改视图buttonViewtableView
货号表面处理工作容积(公制)孔形孔设计
469949MaxiSorp350 μL圆形F8
434797MaxiSorp350 μL圆形F8
441254PolySorp250 μLCC8
441653MaxiSorp250 μL圆形C8
444865PolySorp250 μL圆形C8
445101MaxiSorp250 μL圆形C8
467120MediSorp350 μL圆形F8
467140MultiSorp350 μL圆形F8
467466MaxiSorp350 μL圆形F16(2 x 8 孔)
467679PolySorp350 μL圆形F16
468667MaxiSorp350 μL圆形F8
469078PolySorp350 μL圆形F8
469264亲水250 μLU 形U16
469914MaxiSorp350 μL圆形F16(2 x 8 孔)
469922PolySorp350 μL圆形F16(2 x 8 孔)
469957PolySorp350 μL圆形F8
473709MaxiSorp250 μL圆形C12
473717PolySorp250 μL圆形C12
475078MaxiSorp250 μLU 形U8
475086PolySorp250 μLU 形U8
6302Immulon 2 HB330 μL圆形F12
6309Immulon 2 HB330 μL圆形F12
6310Immulon 1 B330 μL圆形F12
6405Immulon 4 HBX330 μL圆形F12
95029100增强结合350 μL圆形F8
6301TS1
又称 6301
Immulon 1 B330 μL圆形F12
货号 469949
价格(CNY)
4,622.95
飞享价
Ends: 31-Dec-2025
9,245.90
共减 4,622.95 (50%)
Case of 640
添加至购物车
表面处理:
MaxiSorp
工作容积(公制):
350 μL
孔形:
圆形
孔设计:
F8
价格(CNY)
4,622.95
飞享价
Ends: 31-Dec-2025
9,245.90
共减 4,622.95 (50%)
Case of 640
添加至购物车

Thermo Scientific™ Immuno 透明标准板具有为 ELISA 技术开发的 Nunc™、Immulon™ 和 Microtiter™ 模块板,孔与孔之间重复性良好。这些板可与标准设备配套,有助于灵活应用使用小样品量的组件。它们具有行业领先的质量标准和认证的支持。

特点:

  • 几种可拆板条规格:8 孔可拆, 12 孔可拆, 16 孔可拆板条(两排 8 孔可拆板条)
  • 几种孔形:平底,C 型底(平底折角),U 形孔,星形孔(孔内带凸棱,以增加表面积和增强性能)
  • 几种表面修饰,最大程度提升测定性能
  • 翻转过来时,可拆条仍可固定在框架里
  • 框架可堆叠,有方便盖子定位的标记
  • 聚苯乙烯板条,聚乙烯框架
  • 外部尺寸:128 × 86mm

可选表面:

  • Thermo Scientific™ PolySorp™、Immulon™ 1B 和通用结合 (UB) 产品,适用于吸附疏水分子。
  • Thermo Scientific™ Medisorp™ 和 Immulon 2HB 有轻微亲水性,可结合多种生物分子。
  • Thermo Scientific™ MaxiSorp™、Immulon 4 HBX 和增强结合 (EB) 产品具有亲水性,适用于抗体夹心法测定。
  • Thermo Scientific™ MultiSorp™ 表面非常亲水,非常适合多糖和水溶性蛋白。

订购信息:

可拆条为独立式。货货号 95029440 和 464394 有证书。框架和可拆条可单独购买。提供密封膜和硅胶盖。可根据要求提供不同颜色的可拆条。更多详情,请联系您的客户服务或销售代表。

对内部研究使用限制的免责声明:关于买方仅可将产品用于内部研究的任何限制事项并不适用于与此声明相关的网页上的产品。
规格
结合属性亲水
转折点可拆分联排管
认证/合规通过 IgG 吸附认证;孔间 CV < 5%
认证级
检测方法比色法
无盖
每箱数量640
每架数量160
包装640 箱
板封闭
产品类型微孔板联排
数量640 件/箱
靶标分子抗体(糖蛋白)
工作容积(公制)350 μL
孔设计F8
数组1 x 8
颜色透明
产品规格标准
材质聚苯乙烯
孔数量8
表面处理MaxiSorp
孔形圆形
Unit SizeCase of 640

常见问题解答 (FAQ)

What frames do you recommend for your Immuno Clear Standard Modules?

We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.