Alexa Fluor™ 647 NHS 酯(琥珀酰亚胺酯)
Invitrogen17万+抗体限时买二赠一,靶点广,灵活用!
Alexa Fluor™ 647 NHS 酯(琥珀酰亚胺酯)

Alexa Fluor™ 647 NHS 酯(琥珀酰亚胺酯)

Alexa Fluor™ 647 是一种明亮且光稳定的远红外荧光染料,其激发光谱非常适合于 633 nm 激光谱线。Alexa Fluor™ 647了解更多信息
Have Questions?
更改视图buttonViewtableView
货号数量
A201065 mg
A375733 x 100μg
A200061 mg
A3756625 mg
货号 A20106
价格(CNY)
24,502.00
Each
添加至购物车
数量:
5 mg
价格(CNY)
24,502.00
Each
添加至购物车
Alexa Fluor™ 647 是一种明亮且光稳定的远红外荧光染料,其激发光谱非常适合于 633 nm 激光谱线。Alexa Fluor™ 647 染料用于成像和流式细胞分析中稳定信号的生成,具有水溶性和 pH 值不敏感性 (pH 4 - pH 10)。该长波长 Alexa Fluor™ 染料的荧光人眼不可见,但很容易被大多数成像系统检测到。除反应性染料制剂外,我们还提供可与多种抗体、肽、蛋白、示踪剂和扩增底物偶联并且针对细胞标记和检测进行优化的 Alexa Fluor™ 647 染料(了解更多信息)。

Alexa Fluor™ 647 的 NHS 酯(或琥珀酰亚胺酯)是将该染料与蛋白或抗体偶联的较常用工具。NHS 酯可用于标记蛋白、胺修饰的寡核苷酸和其他含胺分子的伯胺 (R-NH2)。所得 Alexa Fluor™ 偶联物将显示出比其他光谱相似荧光基团的偶联物更亮的荧光和更高的光稳定性。

关于该 AlexaFluor™ NHS 酯的详细信息:

荧光基团标记:Alexa Fluor™ 647 染料
反应性基团:NHS 酯
反应性:蛋白和配体、胺修饰的寡核苷酸上的伯胺
偶联物的 Ex/Em:651/672 nm
消光系数:270,000 cm-1M-1
光谱类似染料:Cy5™
分子量:∼1250

典型偶联反应
您可以将胺反应性试剂与几乎任何蛋白或肽偶联(提供的方案针对 IgG 抗体进行了优化)。您可以针对任何量的蛋白按比例缩放反应,但为了获得最佳结果,蛋白的浓度应至少为 2 mg/mL。我们建议使用三种不同的反应性试剂/蛋白摩尔比进行三种不同程度的标记。

Alexa Fluor™ NHS 酯通常溶于高质量的无水二甲基甲酰胺 (DMF) 或二甲亚砜 (DMSO) (D12345) 中,并在 0.1–0.2 M 碳酸氢钠缓冲液(pH 值 8.3)中于室温下进行反应,持续 1 小时。由于末端胺的 pKa 低于赖氨酸 ε-氨基基团的 pKa,您可以使用接近中性 pH 值的缓冲液对胺末端进行更具选择性的标记。

偶联物纯化
通常使用凝胶过滤柱(如 Sephadex™ G-25、BioGel™ P-30 或等效柱)将标记抗体与游离 Alexa Fluor™ 染料分离。对于更大或更小的蛋白,选择具有适当分子量滤除点的凝胶过滤介质或通过透析纯化。我们提供了多种优化的纯化试剂盒,可用于不同量抗体偶联物:
0.5-1 mg 用抗体偶联物纯化试剂盒 (A33086)
20-50 µg 用抗体偶联物纯化试剂盒 (A33087)
50-100 µg 用抗体偶联物纯化试剂盒 (A33088)

了解关于蛋白和抗体标记的更多信息
我们提供一系列 Molecular Probes™ 抗体和蛋白标记试剂盒,旨在满足您的起始材料和实验设置需求。参见我们的抗体标记试剂盒或使用我们的标记化学选择工具进行其他选择。欲了解有关我们标记试剂盒的更多信息,请参阅 Molecular Probes™ 手册中第 1.2 节—蛋白和核酸标记试剂盒

我们还’可为您定制偶联物
如果您’无法在我们的在线目录中找到’想要的产品,我们还’可为您定制抗体或蛋白偶联物。我们的定制偶联服务是高效和保密的,我们保证我们的工作质量。我们经过ISO 9001:2000认证。
仅供科研使用。不可用于诊断程序。
规格
发射672 nm
激发651 nm
适用于(应用)标记化学、蛋白标记和交联
标签或染料Alexa Fluor™ 594
分子量∽1250 (g/mol)
产品类型NHS 酯(琥珀酰亚胺酯)
纯度HPLC,647 nm 波长处 98%
数量5 mg
颜色蓝色
pH 范围4 - 10
Unit SizeEach
内容与储存
-5°C 至 -30°C

常见问题解答 (FAQ)

I am labeling a protein with Alexa Fluor 488 SDP ester. The manual recommends using a sodium bicarbonate buffer at pH 8.3. Can I use a different buffer instead?

Yes. The important thing is to use a buffered solution with a pH between 8.0 and 8.5. Do not use Tris buffer, which has amine groups. Most other buffers will work fine in that pH range. This is also true for other amine-reactive dyes, such as succinimidyl (NHS) esters or TFP esters.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I am not going to use all of my Alexa Fluor succinimidyl ester reactive dye. Can I just make it up in DMSO and store aliquots at -20 degrees C?

This is not recommended. Any trace amounts of water in the DMSO can promote spontaneous hydrolysis over time. Even if using anhydrous DMSO, DMSO is hygroscopic; it readily absorbs moisture from the atmosphere over time. A better alternative is to dissolve the reactive dye in a volatile solvent, make smaller aliquots and then evaporate off the solvent using a vacuum pump. The smaller aliquots of solid reactive dye should then be stored frozen, desiccated and protected from light. Contact Technical Support by sending an email to techsupport@thermofisher.com for the recommended volatile solvent.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

引用和文献 (93)

引用和文献
Abstract
Ubiquitination screen using protein microarrays for comprehensive identification of Rsp5 substrates in yeast.
Authors:Gupta R,Kus B,Fladd C,Wasmuth J,Tonikian R,Sidhu S,Krogan NJ,Parkinson J,Rotin D
Journal:Molecular systems biology
PubMed ID:17551511
Ubiquitin-protein ligases (E3s) are responsible for target recognition and regulate stability, localization or function of their substrates. However, the substrates of most E3 enzymes remain unknown. Here, we describe the development of a novel proteomic in vitro ubiquitination screen using a protein microarray platform that can be utilized for the ... More
Authors:
Journal:
PubMed ID:16263709
Surface plasmon field-enhanced fluorescence spectroscopy studies of the interaction between an antibody and its surface-coupled antigen.
Authors:Yu F, Yao D, Knoll W
Journal:Anal Chem
PubMed ID:12948127
Surface plasmon field-enhanced fluorescence spectroscopy (SPFS) uses the greatly enhanced electromagnetic field of a surface plasmon mode for the excitation of surface-confined fluorophores. The ability to simultaneously monitor the interfacial refractive index changes and the fluorescence signals in real time offers a huge potential for applications of SPFS in surface ... More
Niemann-Pick C1 functions in regulating lysosomal amine content.
Authors:Kaufmann AM, Krise JP,
Journal:J Biol Chem
PubMed ID:18591242
'Mutations in the late endosomal/lysosomal membrane protein Niemann-Pick C1 (NPC1) are known to cause a generalized block in retrograde vesicle-mediated transport, resulting in the hyper-accumulation of multiple lysosomal cargos. An important, yet often overlooked, category of lysosomal cargo includes the vast array of small molecular weight amine-containing molecules that are ... More
Death-receptor activation halts clathrin-dependent endocytosis.
Authors:Austin CD, Lawrence DA, Peden AA, Varfolomeev EE, Totpal K, De Mazière AM, Klumperman J, Arnott D, Pham V, Scheller RH, Ashkenazi A
Journal:Proc Natl Acad Sci U S A
PubMed ID:16801533
'Endocytosis is crucial for various aspects of cell homeostasis. Here, we show that proapoptotic death receptors (DRs) trigger selective destruction of the clathrin-dependent endocytosis machinery. DR stimulation induced rapid, caspase-mediated cleavage of key clathrin-pathway components, halting cellular uptake of the classic cargo protein transferrin. DR-proximal initiator caspases cleaved the clathrin ... More