CytoVista™ 组织成像室(深度 0.75 mm)
CytoVista™ 组织成像室(深度 0.75 mm)
Invitrogen™

CytoVista™ 组织成像室(深度 0.75 mm)

The CytoVista Tissue Imaging Chamber can be used when imaging fluorescently stained tissue or 3D cell culture. Simply mount this了解更多信息
Have Questions?
货号数量
V113336 chambers
货号 V11333
价格(CNY)
394.00
飞享价
Ends: 31-Dec-2025
530.00
共减 136.00 (26%)
6 chambers
添加至购物车
数量:
6 chambers
价格(CNY)
394.00
飞享价
Ends: 31-Dec-2025
530.00
共减 136.00 (26%)
6 chambers
添加至购物车
The CytoVista Tissue Imaging Chamber can be used when imaging fluorescently stained tissue or 3D cell culture. Simply mount this chamber on your microscope slide. These chambers are made of silicon and are chemically inert, and so are resistant to any clearing reagent. After fluorescently labeling and clearing tissue or 3D cell culture, place the specimen in this chamber along with imaging solution. Then place a coverslip on top and you are ready to image.

Features of the CytoVista family of tissue and 3D cell culture clearing reagents include:
• Rapid clearing of fluorescently labeled tissue for 3D imaging
• Minimal shrinkage, expansion, or other morphological changes to tissue
• Simple workflow does not require any special instruments or equipment and is easily adapted to IHC
• Compatible with most fluorophores, including dyes and fluorescent proteins

The CytoVista tissue and 3D cell culture clearing workflow clears tissue or 3D cultured cells with minimal changes to morphology or the sensitivity of detection with almost any fluorophore. With an easy-to-use protocol, whole mouse brain (8-mm section) can be cleared in 24 hours, or a 1-mm section in 2 hours, without the use of any special instruments or equipment.

The CytoVista clearing workflow is compatible with most fluorophores, including fluorescent proteins that are detected with common fluorescent imaging instruments, such as wide-field microscopes, high content analyzers, confocal microscopes, and lightsheet microscopes. For first time users, we recommend the CytoVista Tissue Clearing/Staining Kit (Cat No V11324) or CytoVista 3D Cell Culture Clearing/Staining Kit (Cat No. V11325). These kits contain all necessary reagents for both clearing and IHC staining.

CytoVista clearing technology sufficiently clears tissue for 3D fluorescent imaging, but unlike other clearing techniques does not significantly changes the tissue morphology. Minimal morphological changes, such as shrinkage and contraction, have been observed. For precious samples, the clearing can be reversed, and the tissue can be processed for histology studies, like H&E staining.

For tissues that are easier to clear, like brain, lung, intestine, skin, and tissues of less than 250-μm thickness, treatment with CytoVista Tissue Clearing Reagent is sufficient for 3D imaging. However, tissues of more than 250-μm thickness or that are hard to clear like kidney, liver, heart, and placenta will require an initial treatment with CytoVista Tissue Clearing Reagent followed by treatment with CytoVista Tissue Clearing Enhancer.

CytoVista 3D Cell Culture Clearing Reagent is recommended for spheroids or organoids up to 1 mm in thickness.

For hard tissues like bone, cartilage, and connective tissue, CytoVista Tissue Clearing Reagent is not recommended.
仅供科研使用。不可用于诊断程序。
规格
每架数量6 chambers
数量6 chambers
运输条件室温
材质硅胶
产品线Image-iT™
表面处理细胞培养
厚度(公制)0.75 mm
类型成像腔室
Unit Size6 chambers
内容与储存
在室温下储存。

常见问题解答 (FAQ)

Do I need to seal the outer edges of the CytoVista Tissue Imaging chamber touching the glass, to prevent liquid from leaking out?

This should not be required as the silicone naturally adheres to the glass. If sealing is desired, you may seal with melted paraffin or VALAP at the outer edges.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What are the dimensions of the CytoVista Tissue Imaging chambers?

The CytoVista Tissue Imaging chambers have an outer perimeter of 25 mm x 25 mm and an inner diameter of 16 mm; they vary in thickness.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

How can I paste the CytoVista Tissue Imaging chamber onto a glass coverslip or slide?

The silicone naturally adheres to glass.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.