Selectris 与 Selectris X 成像过滤器

通过零损失能量滤波增强的冷冻电子显微镜成像,实现原子分辨率。

Thermo Scientific  Selectris 和 Selectris X 成像过滤器可用于 Thermo Scientific Krios与 Glacios 系列冷冻电镜。它们为镜筒后置式成像过滤器,可改善透射电子显微镜(TEM)图像的对比度,从而获得高分辨率结构,甚至达到原子分辨率。Selectris 的零损失滤波可去除由非弹性散射电子引起的噪声,提高信噪比(SNR)并改善对比度。Selectris 经高稳定性设计,零损失峰位对环境温度变化的敏感性已降到最低,因此无需频繁调谐。

Frequently asked questions about the Selectris Imaging Filters

Thermo Scientific Selectris and Selectris X Imaging Filters are post-column energy filters for cryo-transmission electron microscopy. They use zero-loss filtering to remove inelastically scattered electrons from the image-forming signal, improving image contrast and signal-to-noise ratio in cryo-EM data.

 

This is especially valuable for relatively thick cryo-electron tomography samples as well as single particle analysis, where increased contrast can support imaging closer to focus and improve the quality of data used for high-resolution reconstruction. The Selectris Filters are built for high stability and ease of use, helping you obtain high-resolution structures quickly for novel biological insights.

The Selectris X Imaging Filter builds on the Selectris platform with a more advanced electron-optical design for further aberration correction. This reduces distortion in both the image and energy domains, supporting demanding cryo-EM applications such as high-resolution/atomic-resolution single particle analysis. The Selectris Imaging Filter provides the same core benefits of zero-loss filtering, stability, and ease of use for high-performance cryo-EM workflows.

Vitrified biological samples are radiation sensitive, so cryo-EM data must be acquired under low-dose conditions. This limits the signal available in each exposure and makes image contrast and signal-to-noise ratio critical. Selectris Imaging Filters improve contrast by using zero-loss filtering to remove inelastically scattered electrons from the image-forming signal. This helps improve the signal-to-noise ratio of images, supports high-resolution reconstruction, and can increase the fraction of usable data. As a result, Selectris Imaging Filters can improve productivity across both single particle analysis and cryo-electron tomography workflows.

A Selectris Imaging Filter improves the signal before it reaches the detector by removing inelastically scattered electrons from the image-forming signal. The Thermo Scientific Falcon 4i Direct Electron Detector then quickly records the filtered signal with high DQE using accurate electron-event localization in the instrument’s native EER file format. Together, the Selectris Imaging Filter and Falcon 4i Detector help you extract more useful signal from challenging cryo-ET samples and support demanding high-resolution single particle analysis workflows.

Selectris Imaging Filters are available with new Thermo Scientific Krios and Glacios Cryo-TEMs. Retrofit options may also be available for many Thermo Scientific cryo-TEMs operating with Windows 10. For upgrades of existing systems, compatibility should be confirmed for the specific microscope configuration. 