Custom Plus TaqMan™ RNA 检测(VIC 引物受限)
Custom Plus TaqMan™ RNA 检测(VIC 引物受限)
Applied Biosystems™

Custom Plus TaqMan™ RNA 检测(VIC 引物受限)

Applied Biosystems Custom Plus TaqMan RNA 检测(VIC 引物受限)是我们用于实时定量了解更多信息
Have Questions?
更改视图buttonViewtableView
货号数量
4448513L (2900 reactions), made to order
4448511S (360 reactions), made to order
4448512M (750 reactions), made to order
货号 4448513
价格(CNY)
-
数量:
L (2900 reactions), made to order
Applied Biosystems Custom Plus TaqMan RNA 检测(VIC 引物受限)是我们用于实时定量 PCR 的预设计 TaqMan 检测的定制版本。Custom Plus TaqMan RNA 检测包括一对未标记的 PCR 引物和一条 TaqMan 探针,探针 5’ 端带有染料标记 (VIC),3’ 端带有小沟结合物 (MGB) 和非荧光淬灭剂 (NFQ)。

特点包括:
易于使用—只需添加 cDNA 和预混液,然后运行 qPCR—不需要熔解曲线
特异性—TaqMan 检测采用专有的含 MGB 的探针,这种探针比非 MGB 探针少了多达 15 个碱基,从而提高了检测的特异性
灵敏性—TaqMan 检测是测量低表达水平或低丰度靶标的理想选择
准确性—可以识别较小的倍数变化,具有较高的定量准确度
定制内容—可轻松设计超过 20 个物种的检测方案
多通路分析的理想选择—结合 FAM 标记和 VIC 标记测定法,可在同一个 qPCR 孔中对两个不同的基因靶标进行双通路测定
对照检测的理想选择—可将 VIC 引物受限检测用于高表达内参基因
设计优势:利用了 TaqMan 检测设计管线的全部生物信息学功能,该管线使用专有算法生成了数百万个检测方案,被视为 qPCR 设计的行业基准

预计发货时间
定制:北美 4–6 天,欧洲 6–10 天

TaqMan 基因表达检测是实时 PCR 基因表达研究的金标准,建立在超过 20 年经验的基础上。每种测定均包括目标引物和序列特异性探针(已经过优化从而获得较佳的功能表现)。无需额外设计、优化或熔解曲线分析。可提供多种形式和种属,不断增加新的测定设计以满足您的研究需求。TaqMan 检测已被超过 40,000 篇已发表文章引用,并且获得超过 350 项专利的支持。

推荐的预混液:TaqMan Fast Advanced预混液

规格
适用于(设备)7500 系统、7500 Fast 系统、7900HT 系统、StepOne™、StepOnePlus™、ViiA™ 7 系统、QuantStudio™ 3、QuantStudio™ 5、QuantStudio™ 6 Flex、QuantStudio™ 7 Flex、QuantStudio 6 Pro、QuantStudio 7 Pro、QuantStudio™ 12k Flex
反应次数2900 次反应
产品线TaqMan™
数量L (2900 reactions), made to order
运输条件Room Temperature
最大浓度60X
Unit SizeEach

常见问题解答 (FAQ)

Can I check the end product of a TaqMan Gene Expression Assay by running an agarose gel?

Yes, you can check the end product on an agarose gel. If you use the TaqMan Universal PCR Master Mix (including AmpErase UNG, Cat. No. 4304437), we recommend running the gel immediately after the PCR, since the trace amount of AmpErase UNG may digest the end product that contains double-stranded DNA with dUTP incorporated. The average length of amplicon ranges from 50-150 bp. The exact amplicon length is indicated on the detailed page of each assay on our website. You can get to that page by clicking on the Assay ID; the amplicon information is listed in the section "Assay Details".

How can I reorder a Custom TaqMan Assay that I ordered previously?

To reorder the same Custom TaqMan Assay, you can follow these steps:
- Select an appropriate catalog number, considering the size of the assay that you want. You can find the different catalog numbers for Custom TaqMan Assays on their respective product pages on thermofisher.com.
- Once you have identified the necessary catalog number, go to www.thermofisher.com and click on "Quick Order", in the top right corner of the screen.
- In the following page, paste your selected catalog number in the "Catalog Number" field and paste the assay ID from your previous order in the "Assay ID" field.
- Click "Add to cart" and then in the following screen click "Proceed to check out".

Can I perform a one-step RT-PCR reaction using TaqMan Gene Expression Assays?

While TaqMan Gene Expression Assays can be used to perform a one-step RT-PCR reaction, these assays have not been optimized for this application. TaqMan Gene Expression Assays have been designed, tested, and optimized using Applied Biosystems universal conditions for a two-step RT-PCR reaction.

Did you take into account sequence homology when you developed the TaqMan Gene Expression Assays product?

During the TaqMan Gene Expression Assays product (including TaqMan Gene Expression Assays and Custom Plus TaqMan RNA Assays) design process, we take the following steps to avoid regions of ambiguity: 1. We BLAST the primer and probe designs against transcript databases to ensure specificity to ensure the chosen assay detects only transcript(s) from the gene of interest. 2. We BLAST primer and probe designs against genome databases in order to avoid assays that detect pseudo-genes or genomic DNA.

When preparing the TaqMan or Custom TaqMan Gene Expression Assays, what is the recommended reaction volume?

When preparing the TaqMan or Custom TaqMan Gene Expression Assays, the recommended and supported volume is 20-50 µL for a 96-well standard plate set-up; 10-20 µL for a 96-well fast plate set-up and 5-10 µL for a 384-well set-up. For more information, please consult the TaqMan Gene Expression Assays and Custom TaqMan Gene Expression Assays protocols.

Find additional tips, troubleshooting help, and resources within our TaqMan Primers and Probes Support Center.