GeneChip™ Hybridization Control Kit
Product Image
Applied Biosystems™

GeneChip™ Hybridization Control Kit

The GeneChip™ Hybridization Control Kit is required for use with GeneChip eukaryotic expression arraysEach kit contains 20X Hybridization Control StockRead more
Have Questions?
Catalog number 900454
Price (CNY)
-
The GeneChip™ Hybridization Control Kit is required for use with GeneChip eukaryotic expression arrays

Each kit contains 20X Hybridization Control Stock composed of pre-mixed biotin-labeled bioB, bioC, bioD and cre, in staggered concentrations, ready to be added directly to the hybridization cocktail. These controls facilitate monitoring of the hybridization process for troubleshooting.

In addition, this kit also contains Control Oligo B2, used to provide alignment signals for image analysis. (Additional Oligo B2 can be ordered separately.)

All kit components have been thoroughly tested to ensure they meet our high-quality standards.

Labeled with the GeneChip IVT Labeling Kit, these control kits replace the previous generation Hybridization Control Kits.

The GeneChip™ Hybridization Control Kit is also available as part of the Complete Reagent Packages for Eukaryotic Arrays.

Related Links
B2 Control Oligo (3nM)
GeneTitan™ Hybridization, Wash, and Stain Kit for WT Array Plates
GeneTitan™ Hybridization, Wash, and Stain Kit for 3' IVT Arrays
GeneChip™ miRNA 4.1 24-Array Plate and Trays
GeneChip™ miRNA 4.1 96-Array Plate and Trays
GeneChip™ miRNA 3.1 24-Array Plate and Trays
GeneChip™ miRNA 3.1 96-Array Plate and Trays
For Research Use Only. Not for use in diagnostic procedures.
Specifications
For Use With (Application)Transcriptome Profiling
Product LineGeneChip™
Quantity1 kit
Reagent TypeHybridization Control
TypeHybridization Control Kit
FormatArray Cartridge
Unit SizeEach

Frequently asked questions (FAQs)

How many freeze/thaws has the 20X Hybridization Control Stock, in the GeneChip Hybridization Control Kit, been validated for?

The 20X Hybridization Control Stock has been validated for 3 freeze/thaws.

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

What are the contents of the GeneChip Hybridization Control Kits?

We offer two GeneChip Hybridization Control Kits, that differ in size:
- Cat. No. 900454: 30 rxns
- Cat. No. 900457: 150 rxns
Both contain 20X Hybridization Control Shock and Control Oligo B2.

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

What signal and fold-change concordance can I expect between Affymetrix miRNA 4.0 and miRNA 4.1 Arrays and miRNA 3.0 and miRNA 3.1 Arrays?

You should expect high signal and fold-change concordance for transcripts with identical probes on the miRNA 4.0 and miRNA 4.1 Arrays and the miRNA 3.0 and miRNA 3.1 Arrays. The snoRNA, scaRNA, and precursor miRNA probe sets were reselected, and for some probe sets in these categories, the probes are not identical between the two array designs. Because the probes selected may be different, one may observe changes in the probe set signal summary for a given target. This is possible as different probe sequences will have varying affinity to the target and may show a higher or lower absolute probe signal depending on the GC content of the probes. However, fold changes are typically well-correlated to the legacy probe set unless there is cross-hybridization in the legacy probe set. Our expectation is that more unique and specific probes result in more specific hybridization to the intended target, and therefore a better performing probe set. Target preparation replicates of human brain and lung samples were pooled and hybridized to four miRNA 3.0 Arrays and four miRNA 4.0 Arrays. The Pearson product moment correlation was calculated from the median signal of matched probe sets and from the median fold change of detected matched probe sets on the miRNA 3.0 Array compared to the miRNA 4.0 Array. Probe sets were defined as detected if the median DABG p-value of the four miRNA 3.0 Array brain replicates was less than 0.06. Two subsets of matched probe sets were used for miRNA 3.0 Array to miRNA 4.0 Array signal and fold change correlation: All human probe sets including those that do not necessarily share identical probe sequences and human probe sets for which the probe sequences are identical on both the miRNA 3.0 and miRNA 4.0 Arrays.

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

Do we have to use any Affymetrix Reagents with our assay?

GeneChip Hybridization Control Kit 30 reactions
GeneTitan Hybridization, Wash, and Stain Kit for miRNA Array Plates 96 reactions
GeneTitan Hybridization Module for miRNA Plates 96 reactions
Affymetrix FlashTag Biotin HSR RNA Labeling Kit 10 reactions
Affymetrix FlashTag Biotin HSR RNA Labeling Kit 30 reactions

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

What kind of dynamic range can I expect from Affymetrix miRNA Array Plates?

Affymetrix miRNA Array Plate provides a similar dynamic range to GeneChip miRNA Array.