GeneTitan™ miRNA Array Holding Buffer
Product Image
Applied Biosystems™

GeneTitan™ miRNA Array Holding Buffer

The Genetitan™ and miRNA Array Holding Buffer is a ready-to-use solution, that is required for processing 3' IVT and whole-transcriptRead more
Have Questions?
Catalog NumberQuantity
901582110 mL
Catalog number 901582
Price (CNY)
-
Quantity:
110 mL
Specifications
For Use With (Application)miRNA Profiling
Quantity110 mL
Reagent TypeHolding Buffer
TypemiRNA Array Holding Buffer
Format24-array Plate, 96-array Plate
Unit SizeEach

Frequently asked questions (FAQs)

How long can I store my GeneChip miRNA 3.1 Array Strip after wash/stain, but before scanning?

The array strip may be stored at 4 degrees C in GeneTitan miRNA Array Holding Buffer (Cat. No. 901582) for up to 24 hours prior to scanning with negligible impact on data. Please equilibrate the array strip to room temperature before scanning.

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

What signal and fold-change concordance can I expect between Affymetrix miRNA 4.0 and miRNA 4.1 Arrays and miRNA 3.0 and miRNA 3.1 Arrays?

You should expect high signal and fold-change concordance for transcripts with identical probes on the miRNA 4.0 and miRNA 4.1 Arrays and the miRNA 3.0 and miRNA 3.1 Arrays. The snoRNA, scaRNA, and precursor miRNA probe sets were reselected, and for some probe sets in these categories, the probes are not identical between the two array designs. Because the probes selected may be different, one may observe changes in the probe set signal summary for a given target. This is possible as different probe sequences will have varying affinity to the target and may show a higher or lower absolute probe signal depending on the GC content of the probes. However, fold changes are typically well-correlated to the legacy probe set unless there is cross-hybridization in the legacy probe set. Our expectation is that more unique and specific probes result in more specific hybridization to the intended target, and therefore a better performing probe set. Target preparation replicates of human brain and lung samples were pooled and hybridized to four miRNA 3.0 Arrays and four miRNA 4.0 Arrays. The Pearson product moment correlation was calculated from the median signal of matched probe sets and from the median fold change of detected matched probe sets on the miRNA 3.0 Array compared to the miRNA 4.0 Array. Probe sets were defined as detected if the median DABG p-value of the four miRNA 3.0 Array brain replicates was less than 0.06. Two subsets of matched probe sets were used for miRNA 3.0 Array to miRNA 4.0 Array signal and fold change correlation: All human probe sets including those that do not necessarily share identical probe sequences and human probe sets for which the probe sequences are identical on both the miRNA 3.0 and miRNA 4.0 Arrays.

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

Do we have to use any Affymetrix Reagents with our assay?

GeneChip Hybridization Control Kit 30 reactions
GeneTitan Hybridization, Wash, and Stain Kit for miRNA Array Plates 96 reactions
GeneTitan Hybridization Module for miRNA Plates 96 reactions
Affymetrix FlashTag Biotin HSR RNA Labeling Kit 10 reactions
Affymetrix FlashTag Biotin HSR RNA Labeling Kit 30 reactions

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

What kind of dynamic range can I expect from Affymetrix miRNA Array Plates?

Affymetrix miRNA Array Plate provides a similar dynamic range to GeneChip miRNA Array.

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

How do results from GeneChip miRNA Cartridge Array compare to Affymetrix miRNA Array Plates?

When evaluating non-control probe sets in common to both arrays, we observed very high signal and fold-change correlation for GeneChip miRNA Cartridge Arrays compared to Affymetrix miRNA Array Plates (Pearson correlation coefficients of 0.97-0.98 for signal correlation and Pearson correlation coefficients of 0.96-0.98 for fold-change correlation).

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.