Automated Thermal Cycler (ATC), 96-well
Automated Thermal Cycler (ATC), 96-well
Applied Biosystems™

Automated Thermal Cycler (ATC), 96-well

对于寻求 PCR 工作流程自动化的客户,Applied Biosystems 自动热循环仪 (ATC) 提供了您期望通过 Applied Biosystems 仪器获得的可靠性和性能。现在小巧、易于集成且兼容
Have Questions?
更改视图buttonViewtableView
货号描述
A31490Includes a 3-meter connector cable
A31489Includes a 1-meter connector cable
A31491Includes a 10-cm connector cable
货号 A31490
价格(CNY)
243,041.00
Each
添加至购物车
描述:
Includes a 3-meter connector cable
价格(CNY)
243,041.00
Each
添加至购物车
For customers seeking to automate their PCR workflow, the Applied Biosystems Automated Thermal Cycler (ATC) provides the reliability and performance you’ve come to expect from Applied Biosystems instruments. Now in a small, easy-to-integrate, and compatible format, our Automated Thermal Cycler enables hands-free PCR results.

对于寻求 PCR 工作流程自动化的客户,Applied Biosystems™ 自动热循环仪提供了您期望通过 Applied Biosystems™ 仪器获得的可靠性和性能。现在,以一种小型、易于集成和兼容的形式,我们的新型自动热循环仪提供了解放双手、极小误差的结果。

简化您的 PCR 过程以提高效率

极小的热循环仪占用空间设计可节省空间

  • 灵活的模块设计,节省台面空间
  • 独立的控制面板模块提供了在自动台面上集成时的灵活性
  • 可选择 10 cm、1 米和 3 米线缆

自动盖和循环功能

  • 自动盖与编程兼容,可通过液体处理或板堆垛机实现轻松免手动操作
  • 加热盖玻片向前滑动以盖住板巢,确保热接触并消除蒸发
  • 自动板弹出器有助于确保半裙边或全裙边 96 孔板的板定位一致

通过我们易于安装的软件完全集成您的自动化系统

集成兼容的 SiLA 快速集成编码语言可在您的自动化平台上集成时提供尽可能大的灵活性

直接软件允许您在安装自动化之前运行自动热循环仪

集成兼容的 SiLA 快速集成编码语言可在您的自动化平台上集成时提供尽可能大的灵活性

仅供科研使用。不可用于诊断程序。
规格
描述Includes a 3-meter connector cable
尺寸31.7 x 17.9 x 13.3 cm (12.5 x 7.1 x 5.3 in.)
显示类型无显示屏
高通量能力兼容高通量应用
最大变温速率3.5°C/s(模块),1.8°C/s(样品)
数量1 each
热量准确度±0.25°C(35°C 至 99.9°C)
热量范围0°C 至 105°C
热量均匀性<0.5°C(达到 95°C 后20秒)
用户界面USB Wi-Fi、以太网
电压100 至 240 V
质保期有限质保
瓦数600 W
重量6 kg(13.2 lb.)
模块配置96孔等温模块
容量96孔,0.2 mL,全裙边或半裙边板
产品类型PCR仪(热循环仪,基因扩增仪)
Unit SizeEach
内容与储存
•ATC 区块模块
• ATC 控制模块
• CAT 5 以太网线缆
• 3米接头线缆

常见问题解答 (FAQ)

Do you offer a thermal cycler that will accommodate fully skirted plates?

Among the thermal cyclers we offer, the only one that will accommodate fully skirted plates is the Automated Thermal Cycler (Cat. No. A31489, A31490, A31491).

Find additional tips, troubleshooting help, and resources within our PCR Thermal Cyclers Support Center.

Do any of your thermal cyclers, other than the Automated Thermal Cycler, hold a full skirted PCR plate?

For full skirt plate, a raised heating block is required. None of our thermal cyclers have a raised heating block except the Automated Thermal Cycler.

Find additional tips, troubleshooting help, and resources within our PCR Thermal Cyclers Support Center.

Can I change out the block on my Automated Thermal Cycler (Cat. No. A31490)?

Yes, you can change out the ATC block.

For connecting the ATC block, please see the Automated Thermal Cycler System User Guide, page 15.

Find additional tips, troubleshooting help, and resources within our PCR Thermal Cyclers Support Center.

What is the optimal ramp rate for my thermal cycler?

There is no universal ramp rate for a thermal cycler because both the block and sample ramp rates are different for each thermal cycler. The sample ramp rate changes with the volume of the sample since more time and energy are required to heat higher sample volumes. The ramp rate may also need to be changed for a particular PCR assay or primer pair if you are trying to use the same PCR assay on two different thermal cyclers, for example.

As a reference, the block ramp rate commonly used with DreamTaq Polymerase on the MiniAmp thermal cycler is 3.0 C/sec. In a 50 µL PCR reaction, this translates to a sample ramp rate of ~1 C/sec.

Please refer to the following application note for further information about thermocycler ramp rates: https://assets.thermofisher.com/TFS-Assets/LSG/brochures/Thermal_Cycler_Ramp_RatesAppNote.pdf

Find additional tips, troubleshooting help, and resources within ourPCR Thermal Cyclers Support Center.

How can I monitor my thermal cycler remotely without being on the Cloud?

The Thermal Cycler Fleet Control Software allows monitoring of the following instruments from within a firewall:
SimpliAmp Thermal Cycler
ProFlex PCR System
Veriti Thermal Cycler
VeritiPro Thermal Cycler
Automated Thermal Cycler (ATC)