Variant Reporter™ v1.0 至 v1.1 的升级
Product Image
Applied Biosystems™

Variant Reporter™ v1.0 至 v1.1 的升级

该产品仅可用于升级安装在独立计算机(–非仪器数据采集系统计算机)上的 Variant Reporter™ v1.0。如需升级在数据采集计算机上运行的数据采集系统和辅助分析软件,请联系您的销售代表。仅供研究使用。不适用于诊断用途了解更多信息
Have Questions?
货号数量
44446441 CD
货号 4444644
价格(CNY)
-
数量:
1 CD
该产品仅可用于升级安装在独立计算机(–非仪器数据采集系统计算机)上的 Variant Reporter™ v1.0。如需升级在数据采集计算机上运行的数据采集系统和辅助分析软件,请联系您的销售代表。

仅供研究使用。不适用于诊断用途。
仅供科研使用。不可用于诊断程序。
规格
数据录入测序图谱
数据输出含序列比较指标的Variant Reports
适用于(应用)测序
适用于(设备)310 基因分析仪、3100 基因分析仪、3100-Avant 基因分析仪、3130xl 基因分析仪、3730xl DNA 分析仪、3500 基因分析仪、3730 DNA 分析仪
许可证静态
操作系统Windows Vista Business、Windows XP Pro
产品线Variant Reporter
产品类型v1.1 升级
数量1 CD
软件比较测序
系统要求计算机:Core 2 Duo E8400/3 GHz;2 GB RAM
Unit SizeEach
内容与储存
包含一张软件 CD。

常见问题解答 (FAQ)

Can Ct's greater than a cut-off be considered valid results?

Yes they can. However, it is important to recognize the true linearity and detection limits of your assay: Ct values above the cut-off can indicate non-specific amplification, unless your NTC is a true- no-target control, and you have run a statistically significant number of replicates. Any results with Ct above the recommended cut-off need to be validated with individual assays on plates.

What is a good Ct cut-off for the TaqMan MicroRNA Array Cards and TaqMan Advanced miRNA Array Cards? In other words, beyond what Ct should I not trust the data?

The typical Ct cut-off on TaqMan Array Cards is 32, which is equivalent to Ct 35 on a plate (10 µl reaction). Previous studies show that if you use pre-amplification, a Ct cut-off of 29 or 30 can be used to reduce numbers of false positives (see Technical Note Optimized protocols for human or rodent microRNA profiling with precious samples). To ensure that you have selected a correct cut-off, you should run replicates of the same sample and use Ct cut-off before you see an increase in the Standard Deviation.

We are upgrading to the Windows 10 operating system. What are the compatible capillary electrophoresis secondary analysis software with Windows 10?

The following capillary electrophoresis secondary analysis software are compatible with Windows 10 (and also Windows 7):

-Sequencing Analysis Software v7
-SeqScape Software v4
-Variant Reporter Software v3
-GeneMapper Software v6
-Minor Variant Finder v1.2
-MicrobeBridge v1.1

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Software Support Center.

Where do I get the latest Applied Biosystems Capillary Electrophoresis Software patches?

Please visit our Applied Biosystems Genetic Analyzer Freeware and Patches website: https://www.thermofisher.com/sangerpatches

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Software Support Center.

How can I import my data from Variant Reporter Software?

For importing data, there are many ways to do so:

More information on backing up the Data Store can be found in the Variant Reporter Help Contents under the keyword “Back-up”.

1. Select the Data Store where you would like the data imported to. To choose a Data Store:
a. Click the Manage button in the Data Store section of the Dashboard View.
b. Highlight the Data Store you wish to use and click on Change Location to select it. Click Close to close the window.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Software Support Center.