Pierce™ 可逆蛋白质染色试剂盒(PVDF 膜)
Pierce™ 可逆蛋白质染色试剂盒(PVDF 膜)
Thermo Scientific™

Pierce™ 可逆蛋白质染色试剂盒(PVDF 膜)

The Thermo Scientific Pierce Reversible Protein Stain Kit for PVDF Membranes is a rapid and sensitive alternative to Ponceau S了解更多信息
Have Questions?
货号 24585
价格(CNY)
2,546.00
Each
添加至购物车
请求批量或定制报价
价格(CNY)
2,546.00
Each
添加至购物车
The Thermo Scientific Pierce Reversible Protein Stain Kit for PVDF Membranes is a rapid and sensitive alternative to Ponceau S stain for protein detection on PVDF membrane after transfer from polyacrylamide gels.

Features of the Reversible Protein Stain Kit for PVDF Membranes:

Better than Ponceau S—more sensitive, easier to document, permanent until reversed (does not fade)
Sensitive—high-avidity, total-protein stain; lower limit of detection equals 25 to 50 ng per band
Specific—detects only protein; does not bind or interact with other electrophoresis or sample components
Rapid—stain in less than 30 minutes; completely erase and reverse staining in less than 15 minutes
Stable—components are stable at room temperature, saving refrigerator space and eliminating equilibration steps

This kit for membrane staining uses a nondestructive, reversible, reliable and sensitive method to stain and detect proteins on PVDF membranes. The kit is a superior alternative to Ponceau S stains for evaluating the efficiency of protein transfer following SDS-PAGE and before immunoblotting. The lower limit of detection with this method is 25 to 50 ng per band (at least five times more sensitive than traditional Ponceau S staining). The staining protocol is simple, quick and results in turquoise-blue bands that do not fade and are easily photographed for future reference. The stain can be easily reversed in less than 15 minutes. Subsequent western blot detection is unaffected because the stain does not alter the protein and is completely removed.

The Pierce Reversible Protein Stain Kit for PVDF Membranes has excellent avidity for a broad range of proteins, resulting in low protein-to-protein variability and enabling most proteins to be detected at very low levels (25 to 50ng per band). Pierce Membrane Stain is superior to other protein stains available for PVDF membranes. For example, Ponceau S is less sensitive and results in red bands that easily fade and are difficult to photograph. Coomassie dye is a sensitive stain, but it permanently binds to proteins and can interfere with western blotting.

The kit uses a dye that has a high affinity for protein but does not permanently bind. The stain has minimal nonspecific interactions with the membrane surface and protein-transfer reagents, and the technique is compatible with general western blot systems. The treated membrane does not interfere with conventional chemiluminescent or chromogenic detection using HRP and alkaline phosphatase substrates. In addition, the stain is compatible with N-terminal sequence analysis of proteins excised and eluted from membrane.

Related Products
Pierce™ Reversible Protein Stain Kit for Nitrocellulose Membranes
0
For Research Use Only. Not for use in diagnostic procedures.
规格
描述Pierce 可逆蛋白质染色试剂盒(PVDF膜)
检测定位印迹检测
检测方法比色法
产品线Pierce™
产品类型可逆性蛋白染色试剂盒
数量1.75 L
靶标分子蛋白质
标签或染料具有专利技术的预混液
Unit SizeEach

常见问题解答 (FAQ)

我在使用MemCode可逆性蛋白质染色剂试剂盒时,发现染色剂不是完全可逆的。这是为什么?

以下是可能原因和解决方案:

- 在逆转处理前,膜是干燥的:保持膜处于湿润状态。
- 样品中的蛋白含量较高:将膜在Stain Eraser溶液中的孵育时间延长至5分钟。 降低样品中的蛋白浓度。

我使用MemCode可逆性蛋白质染色剂试剂盒时,条带很微弱或完全看不见。这是为什么?

这可能是因为样品中的蛋白质含量很低或无蛋白质。请检测原始样品中的蛋白浓度。

用于硝化纤维素膜的MemCode可逆性蛋白质染色试剂盒的灵敏度是多少?

用于硝化纤维素膜的MemCode可逆性蛋白质染色试剂盒可检测到蛋白质含量低至25-50 ng的条带。

用于硝化纤维素膜的Thermo Scientific MemCode可逆性蛋白质染色试剂盒应如何保存?保质期是多久?

用于硝化纤维素膜的MemCode可逆性蛋白质染色试剂盒可在室温下稳定保存1年。

Are SuperBlock Blocking Buffers compatible with the Pierce Reversible Protein Stain Kit for PVDF Membranes (Cat. No. 24585)?

The procedure for the Reversible Protein Stain Kit for PVDF Membranes (Cat. No. 24585) is performed before the membrane is blocked with the blocking buffer, and thus, has no effect on the subsequent blocking.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.