Search
Search
1-step RT-qPCR master mixes enable efficient RNA detection across gene expression, microbial detection and surveillance, microRNA analysis, and multiplex research workflows. By combining reverse transcription and real-time PCR in a single reaction, these solutions help simplify setup, accelerate RNA-to-result turnaround, and support consistent, scalable performance in high-demand laboratory environments.
Designed to support:
|
|
|
|
Order master mixes |
4391178—100 reactions 4389986—500 reactions |
Rox 4444432—200 reactions 4444434—1,000 reactions 4444436—2,000 reactions |
No Rox 5555534—1,000 reactions 5555536—2,000 reactions |
Ideal for |
Gene expression | Microbial detection Gene expression |
|
Cycling mode: run time |
Standard: ~90 minutes | Fast: ~27 minutes | |
Multiplexing |
Single-target detection | Up to 3-plex (Rox) Up to 4-plex (No Rox) |
|
Key features |
SYBR chemistry Melt curve compatible Low-abundance sensitivity Two-tube format Widely used production controls |
Probe-based chemistry Fast protocol with high sensitivity Inhibitor tolerant Single-tube format |
|
|
Order with rox or no rox | ||
|
|
|
||
Order master mixes |
With mustang purple
A28525—100 reactions A28526—1,000 reactions A28527—2,000 reactions |
No Rox
A28521—100 reactions A28522—1,000 reactions A28523—2,000 reactions |
Rox
A58666—100 reactions A58667—1,000 reactions A58668—2,000 reactions |
No Rox
A58669—100 reactions A58670—1,000 reactions A58671—2,000 reactions |
Ideal for |
Multiplex gene expression Assay development |
Automated RT-qPCR workflows Advanced multiplex Inhibitor-rich samples Complex matrices |
||
Cycling mode: run time |
Standard: ~36 minutes | Standard: ~34 minutes |
||
Multiplexing |
Up to 4-plex | Up to 5-plex (Rox) Up to 6-plex (No Rox) |
||
Key features |
Probe-based chemistry Reproducible sensitivity Single-tube format |
Enhanced inhibitor tolerance & low copy detection Single-tube format Up to 8 hours benchtop stability |
||
|
Order with mustang purple or no rox | Order with rox or no rox | ||
The Taqpath master mixes are manufactured in an ISO 13485-certified and FDA-registered facility that adheres to the principles of current good manufacturing practices (cGMP).
1-Step master mix solutions are compatible with Applied Biosystems TaqMan assays and QuantStudio real-time PCR systems.
Whether you’re optimizing multiplex assays or enhancing RNA detection workflows, these qPCR resources offer practical insights to support confident experimental design.
Understand the differences between one-step and two-step real-time PCR including workflow design, flexibility, sample handling, and experimental considerations. This resource helps guide selection of the appropriate RT strategy based on application needs and laboratory workflow priorities.
Complete your RT-qPCR workflow with sample preparation kits, assay solutions, and compatible consumables designed to support efficient and reliable RNA detection from extraction to analysis.
Explore answers to key questions about 1-Step qPCR workflow efficiency, multiplex strategies, contamination control, and performance considerations.
A 1-step RT-qPCR master mix combines reverse transcription and real-time PCR amplification in a single reaction tube, enabling RNA-to-result workflows without transferring cDNA between steps. Solutions such as TaqMan Fast Virus 1-Step master mix and TaqPath DuraPlex 1-Step RT-qPCR master mix are designed to simplify setup while supporting sensitive RNA detection across gene expression, microbial detection, and multiplex applications.
In 1-step RT-qPCR, reverse transcription and amplification occur in the same tube. In 2-step RT-qPCR, cDNA synthesis is performed separately before PCR. The 1-step approach, used in solutions such as TaqMan 1-Step Multiplex master mix, can reduce handling steps and consolidate reactions into a single setup. Learn more in the RT-qPCR Learning Center.
1-step RT-qPCR simplifies workflow by combining reverse transcription and amplification in a single reaction, reducing setup steps and sample handling. The closed-tube format helps minimize contamination risk. Solutions such as TaqMan Fast Virus 1-Step Master Mix and TaqPath DuraPlex 1-Step RT-qPCR Master Mix support sensitive RNA detection.
For microbial detection, including viral and bacterial RNA targets, a probe-based 1-step RT-qPCR master mix optimized for sensitivity and inhibitor tolerance is typically recommended. TaqMan Fast Virus 1-Step master mix supports rapid viral detection, while TaqPath DuraPlex 1-Step RT-qPCR master mix is designed for multiplex pathogen panels and complex sample matrices.
For multiplex RT-qPCR, choose a master mix optimized for multi-target detection and compatible dye configurations. TaqMan 1-Step Multiplex master mix supports up to 4-plex workflows, while TaqPath DuraPlex 1-Step RT-qPCR master mix is designed for higher-order multiplexing and challenging samples requiring enhanced inhibitor tolerance.
By combining reverse transcription and amplification into one reaction, 1-step RT-qPCR workflows can reduce total experiment time. In some protocol comparisons, total RT-qPCR time may be reduced by up to 82%, depending on instrument and assay conditions. Fast-cycle master mixes such as TaqMan Fast Virus 1-Step master mix are designed to support accelerated turnaround.
1-step RT-qPCR reduces hands-on steps by combining reverse transcription and amplification in a single reaction, eliminating the need for cDNA transfer. In some workflows, setup steps may be reduced by up to 45%. Single-tube formats, such as those used in TaqPath DuraPlex 1-Step RT-qPCR Master Mix, support simplified workflow design.
For Research Use Only. Not for use in diagnostic procedures.